A Single Line Diagram (SLD) of a Substation shows how electrical power is distributed within the substation.
Include main components like transformers, circuit breakers, disconnect switches, etc.
Show the flow of electricity from the incoming transmission lines to the outgoing distribution lines.
Label all components and indicate their ratings and connections.
Use standard symbols and conventions for clarity.
Consider safet
A room lighting fixture with a modern design and energy-efficient LED bulbs.
Consider the size and shape of the room when designing the fixture
Choose energy-efficient lighting options such as LED bulbs
Incorporate modern design elements for a sleek look
The question is asking the candidate to draw a connection diagram for a specific electrical system.
Start by identifying all the components of the electrical system
Draw a clear and organized diagram showing how each component is connected
Label each connection and component for clarity
Ensure the diagram follows standard electrical symbols and conventions
Double-check the diagram for accuracy and completeness
posted on 25 Dec 2024
Construction building in raising panel installation involves proper planning, coordination, and adherence to safety regulations.
Ensure all necessary materials and equipment are available before starting the installation process
Coordinate with other trades to ensure smooth workflow and avoid conflicts
Follow safety regulations and guidelines to prevent accidents and injuries
Properly train and supervise workers to ensure ...
posted on 19 Jul 2023
I applied via Referral and was interviewed before Jul 2022. There were 3 interview rounds.
Synchronous motors operate at a constant speed determined by the frequency of the power source.
Synchronous motors have a rotor that rotates at the same speed as the rotating magnetic field in the stator.
They are used in applications where constant speed is required, such as in industrial processes or power generation.
Synchronous motors are more efficient than induction motors at higher loads.
They require a separate DC ...
Induction motors rely on induction to produce torque, while synchronous motors require a magnetic field to rotate at a constant speed.
Induction motors do not require any external connections to the rotor, while synchronous motors need a DC power source to create the magnetic field.
Induction motors are self-starting, while synchronous motors require external means to start.
Induction motors are more commonly used in indu...
I applied via Company Website and was interviewed in Mar 2023. There were 3 interview rounds.
Normal introduction and interview
There are various types of electrical motors including AC motors, DC motors, synchronous motors, and induction motors.
AC motors: commonly used in household appliances and industrial applications
DC motors: used in applications where speed control is important, such as in electric vehicles
Synchronous motors: used in applications where precise speed control is required, such as in clocks and timers
Induction motors: widely...
Protection of transformer involves measures to prevent damage from overcurrent, overvoltage, and overheating.
Use overcurrent protection devices such as fuses and circuit breakers to prevent damage from excessive current flow.
Install overvoltage protection devices like surge arresters to safeguard against voltage spikes.
Implement temperature monitoring systems to prevent overheating, such as thermal sensors and cooling ...
DOL starter stands for Direct-On-Line starter, used to start motors by directly connecting them to the power supply.
DOL starter is the simplest and most common type of motor starter.
It directly connects the motor to the power supply without any intermediate starting method.
It provides full voltage to the motor during starting, which can cause high inrush current.
DOL starters are suitable for small to medium-sized motor...
APFC PANEL stands for Automatic Power Factor Correction Panel, used to maintain power factor in electrical systems.
APFC PANEL automatically monitors and corrects the power factor of electrical systems.
It helps in reducing electricity bills by maintaining a high power factor.
APFC PANELs are commonly used in industries and commercial buildings.
They consist of capacitors that are switched on and off based on the load requ...
posted on 25 Oct 2023
posted on 28 Dec 2022
I applied via Naukri.com and was interviewed in Jun 2022. There were 2 interview rounds.
ATS stands for Automatic Transfer Switch. It is used to transfer power supply between two sources. Transformer and motor maintenance procedures and protection methods are essential for their efficient operation. SAP is a software used for enterprise resource planning.
ATS is used to automatically switch power supply between two sources, ensuring uninterrupted power supply.
Transformer maintenance involves regular inspect...
HT motor rating is the maximum power it can handle and FLC is the current it draws at full load.
HT motor rating is expressed in kilowatts (kW) or megawatts (MW).
FLC of HT motor is the full load current it draws at rated voltage and frequency.
FLC is expressed in amperes (A) and varies depending on the motor's power rating and efficiency.
For example, a 1 MW HT motor may have a FLC of 1000 A at 11 kV.
The rating and FLC of...
Plant EHT system and single line diagram of plants.
EHT system refers to Extra High Tension system used in power plants
Single line diagram shows the electrical connections between different components
It is important to have a clear and accurate diagram for safety and maintenance purposes
posted on 27 Jun 2022
I applied via Recruitment Consulltant
Electrical panels can be used by various types of contractors.
Electrical contractors are the most common type of contractors who use electrical panels.
General contractors may also use electrical panels for specific projects.
HVAC contractors may require electrical panels for their heating and cooling systems.
Plumbing contractors may need electrical panels for water heaters or pumps.
Fire protection contractors may use el...
Various types of MCBs are used in the panel.
Type B MCB for general purpose circuits
Type C MCB for circuits with inductive loads
Type D MCB for circuits with high inrush currents
Type K MCB for circuits with high inrush currents and motors
Type Z MCB for circuits with DC components
Type F MCB for circuits with sensitive equipment
Type G MCB for circuits with surge protection
Type L MCB for lighting circuits
AC current changes direction periodically while DC current flows in one direction only.
AC current is used in household appliances while DC current is used in batteries and electronic devices.
AC current can be easily transformed into different voltages using a transformer while DC current cannot.
AC current is more dangerous to humans than DC current because it can cause muscle contractions.
DC current is more efficient f...
Voltage is the measure of electric potential difference between two points in a circuit.
Voltage is measured in volts (V).
It is the force that drives electric current through a circuit.
Voltage can be positive or negative depending on the direction of the current flow.
A battery provides a voltage difference between its terminals to power a circuit.
Voltage drop occurs when there is a decrease in voltage along a circuit du
The question is unclear. Please provide more context.
Please provide more information about the fault.
Are you asking about fault-finding techniques or the number of people required to find a fault?
Without more context, it is difficult to provide a specific answer.
Transformer safety parts include fuses, circuit breakers, and grounding systems.
Fuses protect against overcurrent and short circuits.
Circuit breakers protect against overloads and faults.
Grounding systems prevent electrical shock and protect equipment.
Other safety parts may include temperature sensors and pressure relief devices.
Capacitors are used to store and release electrical energy in circuits.
Capacitors can filter out noise and stabilize voltage in power supplies.
They can also be used in timing circuits and oscillators.
Capacitors are commonly used in audio equipment to filter out unwanted frequencies.
They can also be used in electric motors to improve power factor and efficiency.
Capacitors are essential components in electronic devices a
A sun t relay is a type of time-delay relay used in electrical systems.
It is used to control the operation of a circuit based on a time delay.
It is commonly used in lighting systems to delay turning on or off.
It can also be used in motor control circuits to prevent damage from sudden power surges.
The delay time can be adjusted to suit the specific needs of the circuit.
It works by using a small current to charge a capac...
Under voltage can cause major electrical problems.
Under voltage can cause equipment damage and failure.
It can also lead to power outages and disruptions.
Proper monitoring and maintenance can prevent under voltage issues.
Examples of under voltage problems include brownouts and voltage sags.
posted on 26 Oct 2023
I was interviewed before Oct 2022.
AC and DC both have their own challenges, but AC is generally considered more difficult due to its changing voltage and frequency.
AC involves constantly changing voltage and frequency, which can be more challenging to work with compared to the steady flow of DC.
AC circuits require additional components like capacitors and inductors to manage voltage and current fluctuations.
DC circuits are simpler to understand and tro...
based on 2 interviews
Interview experience
based on 3 reviews
Rating in categories
Associate Manager
324
salaries
| ₹5.3 L/yr - ₹17.2 L/yr |
Junior Manager
241
salaries
| ₹3.5 L/yr - ₹12 L/yr |
Manager
122
salaries
| ₹8.1 L/yr - ₹28 L/yr |
Senior Engineer
112
salaries
| ₹3.6 L/yr - ₹8.5 L/yr |
Executive Accountant
58
salaries
| ₹2.8 L/yr - ₹7.5 L/yr |
Adani Group
Tata Group
Reliance Industries
Essar Group