Filter interviews by
I applied via Recruitment Consultant and was interviewed before Jan 2017. There were 3 interview rounds.
Three types of PLC languages are ladder logic, function block diagram, and structured text.
Ladder logic is the most commonly used language and resembles a ladder with rungs and rails.
Function block diagram uses graphical symbols to represent functions and their connections.
Structured text is a high-level programming language similar to Pascal or C.
Inputs on PLC are signals or data received by the PLC from sensors or other devices.
Inputs can be digital or analog
Digital inputs are either on or off, representing a binary signal
Analog inputs are continuous signals that can represent a range of values
Examples of inputs include temperature sensors, pressure sensors, limit switches, and push buttons
Outputs are the results or products of a process or system.
Outputs are the end result of a process or system
They can be tangible or intangible
Examples include a finished product, a report, or a signal
Outputs can be measured and evaluated for quality and effectiveness
Top trending discussions
I applied via Walk-in and was interviewed in Sep 2022. There were 2 interview rounds.
I applied via AmbitionBox and was interviewed in Nov 2024. There was 1 interview round.
My field of expertise is in commercial and industrial electrical work.
Specialize in installing and maintaining electrical systems in commercial buildings
Experienced in troubleshooting and repairing electrical issues in industrial settings
Knowledgeable in reading blueprints and schematics for large-scale projects
The monthly salary for an Electrician varies depending on experience, location, and employer.
Monthly salary can range from $3,000 to $6,000 or more
Factors such as years of experience, certifications, and type of employer can impact salary
Electricians in high-demand areas or specialized fields may earn higher salaries
I hold a Bachelor's degree in Electrical Engineering.
Bachelor's degree in Electrical Engineering
Specialized courses in electrical systems and circuits
Hands-on training in electrical installations and repairs
I applied via Job Fair and was interviewed in Aug 2024. There were 5 interview rounds.
Current unit ki refers to the unit of measurement for electric current.
Current unit ki is measured in Amperes (A)
1 Ampere is equal to 1 Coulomb per second
Commonly used prefixes for current unit ki are milliampere (mA) and microampere (μA)
AI stands for Artificial Intelligence, which is the simulation of human intelligence processes by machines, especially computer systems.
AI involves the development of algorithms that can perform tasks that typically require human intelligence.
It encompasses various subfields such as machine learning, natural language processing, and computer vision.
AI systems can learn from data, adapt to new inputs, and perform tasks ...
Management reports can be generated using AI by collecting and analyzing data to provide insights and recommendations.
Collect relevant data from various sources such as equipment sensors, maintenance logs, and work orders.
Use AI algorithms to analyze the data and identify patterns, trends, and anomalies.
Generate automated reports with key performance indicators, maintenance schedules, and recommendations for improvemen...
I applied via Job Portal
ITI electrical 1 year experience in Hero Moto corp limited
The current in a 3 phase system depends on the voltage and power of the system.
The current in a 3 phase system can be calculated using the formula: I = P / (sqrt(3) * V)
Where I is the current, P is the power, and V is the voltage
For example, if the power is 1000W and the voltage is 240V, the current would be approximately 4.33A
MCB stands for Miniature Circuit Breaker, a device designed to protect electrical circuits from overloads and short circuits.
MCB is a type of circuit breaker that automatically switches off electrical circuits during abnormal conditions like overload or short circuit.
It is commonly used in residential and commercial electrical installations to protect wiring and electrical equipment.
MCBs are available in different curr...
To check AC DC current, use a multimeter set to the appropriate setting and connect the probes to the circuit being tested.
Set the multimeter to the AC or DC current setting depending on what you are testing.
Ensure the multimeter probes are connected correctly to the circuit being tested.
Read the current measurement displayed on the multimeter.
For AC current, make sure the multimeter is set to the appropriate range (e....
To check cable continuity, use a multimeter to measure resistance between two points on the cable.
Use a multimeter set to the resistance or continuity mode.
Connect one probe to one end of the cable and the other probe to the other end.
A low resistance reading indicates good continuity, while a high resistance or infinite reading indicates a break in the cable.
Check for continuity in each conductor of the cable separate...
PVC stands for Polyvinyl Chloride, a type of plastic commonly used in construction and electrical applications.
PVC is a versatile material known for its durability and resistance to chemicals.
It is commonly used in electrical wiring, plumbing pipes, and vinyl flooring.
PVC is lightweight, easy to install, and cost-effective compared to other materials.
Examples of PVC products include PVC pipes, PVC electrical conduits,
The motor work in AC is based on electromagnetic induction, while in DC it is based on the Lorentz force principle.
AC motors work on the principle of electromagnetic induction, where a changing magnetic field induces a current in the rotor coils.
DC motors operate based on the Lorentz force principle, where a current-carrying conductor in a magnetic field experiences a force.
Examples of AC motors include induction motor...
To decide how to work in safety in electrical equipment
One safety hazard in electrical protection is electric shock.
Electric shock can occur when coming into contact with live electrical parts.
Proper grounding and insulation of electrical equipment is essential to prevent electric shock.
Regular maintenance and inspections of electrical systems can help identify potential hazards.
Using personal protective equipment such as insulated gloves and safety goggles can reduce the ...
Tata Motors
Maruti Suzuki
Asian Paints
Samsung