Vapour compression cycle is a thermodynamic process used in refrigeration and air conditioning systems.
It involves the compression of a refrigerant gas to a high pressure and temperature, followed by condensation into a liquid at a lower temperature.
The liquid refrigerant then passes through an expansion valve, where it undergoes a pressure drop and evaporates at a low temperature and pressure.
The evaporated refrigeran...
1 Btu is approximately equal to 0.252 kcal.
1 Btu is equal to 251.996 calories (cal)
1 calorie (cal) is equal to 0.001 kcal
Therefore, 1 Btu is approximately equal to 0.252 kcal
I applied via Campus Placement and was interviewed in Mar 2023. There was 1 interview round.
RAC stands for Refrigeration and Air Conditioning. It involves the study and application of cooling and heating systems.
RAC deals with the design, installation, and maintenance of systems that control temperature, humidity, and air quality in buildings and vehicles.
It includes various components such as compressors, condensers, evaporators, and refrigerants.
RAC systems are used in refrigerators, air conditioners, heat ...
A P-h diagram is a graphical representation of the pressure-enthalpy relationship in a refrigeration system.
A P-h diagram shows the state points and processes of a refrigeration cycle.
The horizontal axis represents enthalpy, while the vertical axis represents pressure.
The diagram helps in analyzing and designing refrigeration systems.
It is useful for determining the performance and efficiency of the system.
The diagram ...
Insulation is a material or technique used to prevent the transfer of heat, electricity, or sound.
Insulation is used to reduce heat transfer, keeping buildings warm in winter and cool in summer.
Electrical insulation prevents the flow of electricity, protecting people and equipment from electric shocks.
Sound insulation reduces the transmission of sound between spaces, providing acoustic privacy.
Common insulation materia...
Insulation is used to prevent the transfer of heat, sound, or electricity.
Thermal insulation: used to reduce heat transfer
Acoustic insulation: used to reduce sound transmission
Electrical insulation: used to prevent the flow of electricity
Examples: fiberglass, foam, mineral wool, rubber, PVC
VCRs and VARs are both types of electrical devices, but they serve different purposes.
VCR stands for Video Cassette Recorder, which is used to record and play back video tapes.
VAR stands for Voltage-Activated Relay, which is used to control the flow of electricity based on voltage levels.
VCRs are commonly used in home entertainment systems, while VARs are used in electrical power systems.
VCRs are becoming obsolete with...
I applied via Company Website
I applied via Recruitment Consulltant and was interviewed in Feb 2023. There were 2 interview rounds.
Frick India interview questions for popular designations
GST transport related documents include invoice, delivery challan, e-way bill, and transport receipt.
Invoice: A document issued by the supplier containing details of goods or services provided and the amount charged.
Delivery Challan: A document that accompanies the goods being transported, containing details of the goods and the recipient.
E-way Bill: A document required for the movement of goods worth more than Rs. 50,...
The notice period and roles and responsibilities of private company components vary.
Notice period depends on the company policy and the employee's position
Roles and responsibilities are defined in the job description and may vary based on the department
Privately held companies may have different notice periods and roles compared to publicly traded companies
I applied via Walk-in and was interviewed before May 2023. There was 1 interview round.
SCADA stands for Supervisory Control and Data Acquisition. It is a system used for monitoring and controlling industrial processes.
SCADA is used in industries such as power plants, water treatment facilities, and manufacturing plants.
PLC logic development can be done using ladder logic, function block diagrams, and structured text.
Reporting knowledge involves generating reports on system performance and data analysis.
M...
I applied via Referral and was interviewed before May 2022. There were 2 interview rounds.
Vapour compression cycle is a thermodynamic process used in refrigeration systems to transfer heat from a low-temperature environment to a high-temperature environment.
The cycle involves four main components: compressor, condenser, expansion valve, and evaporator.
The refrigerant is compressed by the compressor, which increases its temperature and pressure.
The high-pressure refrigerant then flows to the condenser, where...
1 TR is equal to 12,000 BTU per hour.
TR stands for 'ton of refrigeration', a unit used in air conditioning and refrigeration to measure cooling capacity.
BTU stands for 'British Thermal Unit', a unit of energy used to measure heat.
1 TR is equivalent to 3.51685 kilowatts.
To convert BTU to TR, divide the BTU by 12,000.
Top trending discussions
posted on 18 Jan 2025
I applied via Recruitment Consulltant and was interviewed in Dec 2024. There was 1 interview round.
posted on 28 Jan 2025
I applied via Approached by Company and was interviewed in Nov 2024. There was 1 interview round.
Interview experience
based on 124 reviews
Rating in categories
Assistant Manager
17
salaries
| ₹4.2 L/yr - ₹10 L/yr |
Project Engineer
17
salaries
| ₹3 L/yr - ₹5.5 L/yr |
Engineer
16
salaries
| ₹2.2 L/yr - ₹6.4 L/yr |
Senior Engineer
14
salaries
| ₹4.2 L/yr - ₹7.2 L/yr |
Design Engineer
11
salaries
| ₹2.8 L/yr - ₹4.6 L/yr |
Thermax Limited
Forbes Marshall
Kirloskar Brothers
CG Power and Industrial Solutions