Faster and better experience!
Filter interviews by
I applied via Referral and was interviewed in Sep 2020. There were 5 interview rounds.
A Quality Engineer ensures that products and services meet quality standards and customer expectations.
Develop and implement quality control processes
Conduct audits and inspections to identify defects and areas for improvement
Collaborate with cross-functional teams to resolve quality issues
Analyze data to identify trends and opportunities for improvement
Ensure compliance with industry regulations and standards
Provide t...
The value of humidity at floor depends on various factors such as temperature, ventilation, and moisture content.
Humidity levels should be maintained between 30-60% to prevent mold growth and maintain indoor air quality.
High humidity levels can lead to condensation on surfaces and promote the growth of bacteria and viruses.
Low humidity levels can cause dry skin, respiratory problems, and damage to wooden furniture and ...
PCB stands for Printed Circuit Board while PCBA stands for Printed Circuit Board Assembly.
PCB is the board that contains the circuitry while PCBA is the board with the circuitry and components assembled on it.
PCB is the foundation of electronic devices while PCBA is the final product.
PCB is used in various industries while PCBA is commonly used in electronics manufacturing.
PCB is usually green in color while PCBA can h...
Intensity of light can be checked using a lux meter or a photometer.
Use a lux meter to measure the illuminance of a surface in lux units.
Use a photometer to measure the luminous flux of a light source in lumens.
Ensure that the meter is calibrated and the correct unit is selected.
Measure the light intensity at different points to ensure uniformity.
Take into account the distance between the light source and the meter.
Con...
Top trending discussions
I was interviewed before Jan 2024.
I applied via Company Website and was interviewed before Apr 2023. There was 1 interview round.
Types of wires include solid, stranded, and braided wires. Colors of wires vary depending on their purpose and industry standards.
Types of wires: solid, stranded, braided
Colors of wires vary by industry standards
Common wire colors: black, red, blue, green, white, yellow
I have 5 years of experience as a Quality Inspector.
I have worked as a Quality Inspector for 5 years.
I have gained extensive experience in inspecting and ensuring the quality of products.
During my time as a Quality Inspector, I have developed strong attention to detail and problem-solving skills.
I am familiar with quality control processes and have successfully implemented improvements in previous roles.
I have a track ...
My expectations for the Quality Inspector role include a supportive work environment, clear expectations, opportunities for growth, and a focus on continuous improvement.
Supportive work environment: I expect to work in a team-oriented environment where colleagues and supervisors are helpful and collaborative.
Clear expectations: I expect to receive clear guidelines and instructions on quality standards, inspection proce...
I was interviewed before Jan 2024.
I applied via Company Website and was interviewed before Jun 2021. There were 4 interview rounds.
I applied via Shine and was interviewed in Jun 2022. There were 2 interview rounds.
I applied via Approached by Company and was interviewed in Oct 2022. There were 2 interview rounds.
To check the label, inspect the information printed on it for accuracy and completeness.
Verify that all required information is present on the label, such as product name, ingredients, warnings, and usage instructions.
Ensure that the label is legible and easy to read.
Check for any spelling or grammatical errors on the label.
Confirm that the label meets any regulatory requirements or industry standards.
Compare the label...
To check good harnesses, inspect for proper connections, secure fastenings, correct wire routing, and absence of damage or wear.
Inspect for proper connections between wires and connectors.
Check for secure fastenings, such as properly tightened screws or clamps.
Ensure correct wire routing, with wires organized and protected from potential damage.
Look for any signs of damage or wear, such as frayed wires or broken insula...
The problem mouth press refers to an issue with the pressing mechanism of a machine used in quality inspection.
The problem could be related to a malfunctioning or misaligned press mechanism.
It could result in inconsistent or incorrect pressure being applied during inspection.
Examples of problems could include a stuck press, uneven pressure distribution, or a faulty sensor.
The issue may lead to inaccurate quality assess
I applied via Campus Placement
The least count of vernier caliper is the smallest measurement it can accurately measure. The least count of a micrometer is the smallest measurement it can accurately measure.
The least count of a vernier caliper is typically 0.02 mm or 0.001 inches.
The least count of a micrometer is typically 0.01 mm or 0.001 inches.
Vernier calipers are used to measure dimensions of objects with high accuracy.
Micrometers are used to m...
I applied via Company Website and was interviewed before Apr 2023. There was 1 interview round.
Types of wires include solid, stranded, and braided wires. Colors of wires vary depending on their purpose and industry standards.
Types of wires: solid, stranded, braided
Colors of wires vary by industry standards
Common wire colors: black, red, blue, green, white, yellow
based on 3 reviews
Rating in categories
Assistant Engineer
14
salaries
| ₹2 L/yr - ₹3.6 L/yr |
Engineer
12
salaries
| ₹2.5 L/yr - ₹4.1 L/yr |
Quality Engineer
11
salaries
| ₹1.6 L/yr - ₹4.3 L/yr |
Graduate Engineer Trainee (Get)
9
salaries
| ₹1.1 L/yr - ₹4 L/yr |
Cctv Technician
8
salaries
| ₹1.8 L/yr - ₹6.9 L/yr |
Dahua Technology India Pvt.Ltd.
Axis Communications
Bosch Security Systems
Hanwha Techwin