Filter interviews by
I applied via Recruitment Consulltant and was interviewed before Apr 2022. There were 3 interview rounds.
Technical and core engineering related questions will be asked
Top trending discussions
I applied via Referral and was interviewed in Jul 2024. There was 1 interview round.
To go online in Siemens PLC, you need to connect the PLC to a programming device and use the appropriate software to establish communication.
Connect the Siemens PLC to a programming device using a suitable cable (e.g. Ethernet cable, USB cable)
Open the programming software (e.g. TIA Portal, Step 7)
Select the option to go online with the PLC
Ensure that the communication settings (IP address, port number) are correctly c...
Profibus end terminator resistance is the resistance value at the end of a Profibus network to prevent signal reflections.
Profibus end terminator resistance is typically 100-120 ohms.
It is used to match the characteristic impedance of the transmission line.
The terminator resistor absorbs the signal to prevent reflections at the end of the network.
Incorrect terminator resistance can lead to signal distortion and communi
I applied via Recruitment Consulltant
Topic given and asked to discuss about the topic for 3 min for each candidate.
posted on 19 Oct 2023
I applied via Naukri.com and was interviewed in Apr 2023. There were 4 interview rounds.
Patrolling points can be checked by physically visiting each point on a regular basis to ensure security and safety.
Create a list of all patrolling points
Assign specific officers to check each point
Establish a schedule for regular patrols
Use technology such as GPS tracking to monitor patrol routes
Document any issues or incidents encountered during patrols
Pumps are devices used to move fluids (liquids or gases) by mechanical action.
Centrifugal pumps: use a rotating impeller to increase the pressure of a fluid.
Positive displacement pumps: trap a fixed amount of fluid and then force it into a discharge pipe.
Diaphragm pumps: use a flexible diaphragm to move fluid.
Gear pumps: use interlocking gears to move fluid.
Peristaltic pumps: use rotating rollers to squeeze a flexible ...
Types of maintenance include preventive, corrective, predictive, and proactive maintenance.
Preventive maintenance involves regular inspections and maintenance to prevent breakdowns.
Corrective maintenance is performed after a failure occurs to restore equipment to working condition.
Predictive maintenance uses data and analytics to predict when maintenance is needed.
Proactive maintenance involves identifying and addressi...
Machine health checkup can be done by monitoring key parameters, conducting regular inspections, and performing diagnostic tests.
Monitor key parameters such as temperature, pressure, vibration levels, and fluid levels regularly.
Conduct regular inspections to check for signs of wear and tear, leaks, or abnormal noises.
Perform diagnostic tests like thermography, ultrasonic testing, or oil analysis to detect potential iss...
5S is a methodology for organizing a workplace for efficiency and effectiveness. Poka Yoke is a mistake-proofing technique to prevent errors.
5S stands for Sort, Set in Order, Shine, Standardize, and Sustain. It helps improve productivity, safety, and morale in the workplace.
Examples of 5S include organizing tools in a designated area, labeling storage bins, and implementing regular cleaning schedules.
Poka Yoke is a Jap...
posted on 26 Jun 2024
posted on 3 Apr 2022
I applied via Naukri.com and was interviewed before Dec 2021. There were 3 interview rounds.
I applied via Recruitment Consulltant
Topic given and asked to discuss about the topic for 3 min for each candidate.
I applied via Referral and was interviewed in Jul 2024. There was 1 interview round.
To go online in Siemens PLC, you need to connect the PLC to a programming device and use the appropriate software to establish communication.
Connect the Siemens PLC to a programming device using a suitable cable (e.g. Ethernet cable, USB cable)
Open the programming software (e.g. TIA Portal, Step 7)
Select the option to go online with the PLC
Ensure that the communication settings (IP address, port number) are correctly c...
Profibus end terminator resistance is the resistance value at the end of a Profibus network to prevent signal reflections.
Profibus end terminator resistance is typically 100-120 ohms.
It is used to match the characteristic impedance of the transmission line.
The terminator resistor absorbs the signal to prevent reflections at the end of the network.
Incorrect terminator resistance can lead to signal distortion and communi
What is current
Voltage is the potential difference between two points in a circuit, while emf is the electromotive force that drives current in a circuit.
Voltage is measured in volts (V)
Emf is the energy per unit charge supplied by a source, measured in volts (V)
Voltage is the difference in electric potential between two points in a circuit
Emf is the voltage generated by a source such as a battery or generator
Voltage is necessary for
based on 1 interview
Interview experience
Management Executive
3.6k
salaries
| ₹1.1 L/yr - ₹5.2 L/yr |
Assistant Manager
596
salaries
| ₹3.2 L/yr - ₹12.5 L/yr |
Production Engineer
321
salaries
| ₹1.1 L/yr - ₹5 L/yr |
Associate
289
salaries
| ₹1.3 L/yr - ₹4.5 L/yr |
Territory Leader
190
salaries
| ₹4.5 L/yr - ₹15 L/yr |
Apollo Tyres
MRF Tyres
Bridgestone India Automotive Products
JK Tyres