I applied via Naukri.com and was interviewed in Nov 2022. There were 2 interview rounds.
Yes, I rooted cause the problem and solved it.
Identified the problem by analyzing data and conducting tests
Used root cause analysis techniques such as fishbone diagram or 5 Whys
Implemented corrective actions to address the root cause
Monitored the effectiveness of the solution and made adjustments if necessary
Production control involves implementing strategies and systems to ensure efficient and effective manufacturing processes.
Implementing quality control measures to ensure products meet specifications
Monitoring production processes to identify and address any issues or bottlenecks
Utilizing production planning and scheduling techniques to optimize workflow
Implementing lean manufacturing principles to reduce waste and impr...
I applied via Referral and was interviewed before Jun 2020. There were 5 interview rounds.
Developed a solution for optimizing a complex algorithm for a client in the finance industry
Client had a large dataset that needed to be processed quickly
Implemented parallel processing to speed up the algorithm
Optimized the code to reduce memory usage
Collaborated with the client to fine-tune the algorithm for their specific needs
I applied via Campus Placement and was interviewed before Mar 2020. There were 5 interview rounds.
I applied via Walk-in and was interviewed before Dec 2019. There were 4 interview rounds.
I applied via Apna Jobs and was interviewed in Mar 2022. There were 3 interview rounds.
I will immediately investigate the cause of the NG lot and work with the team to find a solution to make it usable.
Investigate the cause of the NG lot
Work with the team to find a solution
Prioritize urgent use of the lot
Ensure quality control measures are in place
Communicate with stakeholders about the situation
I applied via Approached by Company and was interviewed before Jun 2022. There were 5 interview rounds.
Sub cooling in air conditioning is the process of cooling the refrigerant below its saturation temperature to improve system efficiency.
Sub cooling increases the efficiency of the air conditioning system by ensuring the refrigerant is in a liquid state before entering the expansion valve.
It helps in preventing flash evaporation of the refrigerant, which can lead to inefficiencies in the system.
Sub cooling is typically ...
ISEER rating is calculated based on the weighted average of the cooling performance of an air conditioner under different conditions.
ISEER = (Weighted Cooling Capacity at 100% load x 0.4) + (Weighted Cooling Capacity at 75% load x 0.2) + (Weighted Cooling Capacity at 50% load x 0.4)
The higher the ISEER rating, the more energy efficient the air conditioner is.
ISEER rating helps consumers compare the energy efficiency of...
The refrigeration cycle is a thermodynamic cycle used in refrigerators and air conditioning systems to transfer heat from a low temperature to a high temperature environment.
The cycle consists of four main components: compressor, condenser, expansion valve, and evaporator.
The refrigerant enters the compressor as a low-pressure gas and leaves as a high-pressure, high-temperature gas.
The high-pressure gas then flows into...
Mainstream refrigerants used in household air conditioning include R-410A, R-22, and R-134a.
R-410A is a popular refrigerant known for its high efficiency and environmental friendliness.
R-22, although being phased out due to its ozone-depleting properties, is still commonly found in older air conditioning systems.
R-134a is commonly used in automotive air conditioning systems but can also be found in some household units
1 ton cooling concept refers to the amount of heat required to melt one ton of ice in a 24-hour period.
1 ton of cooling is equal to 12,000 BTUs per hour
It is commonly used in the HVAC industry to measure the cooling capacity of air conditioning systems
For example, a 2-ton air conditioner can remove 24,000 BTUs of heat per hour
The relationship between current, voltage, and power is described by Ohm's Law, which states that current is directly proportional to voltage and inversely proportional to resistance.
Ohm's Law states that V = I * R, where V is voltage, I is current, and R is resistance.
Power (P) is calculated using the formula P = V * I, where P is power, V is voltage, and I is current.
In a circuit with a constant resistance, an increa...
1 BTU is approximately equal to 0.29307107 watts. To convert BTU to watts, multiply by 0.29307107. To convert watts to BTU, divide by 0.29307107.
1 BTU = 0.29307107 watts
To convert BTU to watts, multiply by 0.29307107
To convert watts to BTU, divide by 0.29307107
based on 1 interview
Interview experience
based on 3 reviews
Rating in categories
Assistant Manager
123
salaries
| ₹9 L/yr - ₹21 L/yr |
Senior Engineer
82
salaries
| ₹6.5 L/yr - ₹12 L/yr |
Engineer
61
salaries
| ₹3.6 L/yr - ₹8.8 L/yr |
Deputy Manager
56
salaries
| ₹12 L/yr - ₹25 L/yr |
Area Sales Manager
51
salaries
| ₹7.6 L/yr - ₹23 L/yr |
Vivo
OPPO
Dell
LG Electronics