Filter interviews by
I applied via Walk-in and was interviewed before Feb 2021. There was 1 interview round.
My competencies include technical knowledge, problem-solving skills, attention to detail, and teamwork.
Strong technical knowledge in electrical engineering principles and practices
Ability to solve complex problems and troubleshoot electrical systems
Attention to detail in design, testing, and documentation
Collaborative teamwork skills to work effectively with colleagues and clients
Proficiency in using electrical design ...
As a technical support, I provide prompt and efficient solutions to customer's electrical problems.
Listen to the customer's problem and ask relevant questions to understand the issue
Provide step-by-step instructions to troubleshoot the problem
Offer remote assistance or schedule an on-site visit if necessary
Ensure customer satisfaction by following up after the issue has been resolved
Top trending discussions
I applied via Company Website and was interviewed in Oct 2019. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in Sep 2020. There was 1 interview round.
I applied via Walk-in and was interviewed before Sep 2021. There were 3 interview rounds.
I applied via Referral and was interviewed before Sep 2021. There were 2 interview rounds.
posted on 30 Sep 2021
I applied via Walk-in and was interviewed in Aug 2021. There was 1 interview round.
I applied via Naukri.com and was interviewed in Aug 2021. There were 5 interview rounds.
VFD output formula calculates the output voltage and frequency of a variable frequency drive.
The formula is Vout = Vin x (2/√3) x (Fout/Fin)
Vout is the output voltage, Vin is the input voltage, Fout is the output frequency, and Fin is the input frequency
The formula assumes a three-phase system
The output frequency can be adjusted to control the speed of the motor
Example: If Vin is 480V, Fin is 60Hz, and Fout is 30Hz, th
Output VFD drops due to various factors such as overloading, voltage fluctuations, and motor issues.
Overloading of the motor can cause the VFD output to drop.
Voltage fluctuations can also cause the VFD output to drop.
Issues with the motor, such as a faulty winding, can cause the VFD output to drop.
Inadequate cooling or ventilation can cause the VFD output to drop.
Incorrect programming or settings can cause the VFD outp
PLC and HMI can communicate through various protocols such as Ethernet/IP, Modbus, Profibus, etc.
PLC and HMI can be connected through a physical cable or wireless connection
PLC sends data to HMI through the chosen protocol
HMI displays the data received from PLC and sends commands back to PLC
Programming software is used to configure the communication settings
Examples of protocols used for communication are Ethernet/IP,
VFD is used to control the speed of AC motors, while servo is used for precise control of position, speed, and torque.
VFD is used for variable speed control of AC motors
Servo is used for precise control of position, speed, and torque
VFD is typically used in applications where speed control is the primary concern
Servo is typically used in applications where precise control of position, speed, and torque is required
VFD i...
Encoders are devices that convert motion into an electrical signal.
Encoders can be rotary or linear
They work by detecting changes in position or motion
They can be absolute or incremental
Examples include optical encoders and magnetic encoders
I applied via Naukri.com and was interviewed in Jun 2021. There was 1 interview round.
I applied via Referral and was interviewed in Oct 2021. There were 3 interview rounds.
Assistant Engineer
390
salaries
| ₹2 L/yr - ₹4.8 L/yr |
Deputy Engineer
103
salaries
| ₹3.2 L/yr - ₹6.7 L/yr |
Assistant Manager
86
salaries
| ₹5.5 L/yr - ₹15.4 L/yr |
Engineer
72
salaries
| ₹3 L/yr - ₹6.9 L/yr |
Service Engineer
65
salaries
| ₹2.4 L/yr - ₹5.8 L/yr |
Bosch
JBM Group
Samvardhana Motherson Group
Subros