Adani Green Energy
40+ Rimini Street Interview Questions and Answers
Q1. What is the use of star delta connection in electrical ?
Star delta connection is used to start high power motors with reduced starting current and torque.
Reduces starting current and torque
Used for high power motors
Improves motor efficiency
Reduces voltage drop during starting
Reduces stress on motor windings
Example: Starting a large induction motor in an industrial setting
Q2. What Kinds of Cables Are Used for Power Transmissions?
Different types of cables are used for power transmission, including overhead lines, underground cables, and submarine cables.
Overhead lines are commonly used for power transmission over long distances.
Underground cables are used in urban areas where overhead lines are not feasible.
Submarine cables are used for power transmission between islands or across bodies of water.
Different types of cables, such as aluminum cables and copper cables, are used based on the specific requi...read more
Q3. Mention what is the difference between generator and alternator ?
Generators and alternators are both electrical machines that convert mechanical energy into electrical energy, but they differ in their construction and working principles.
Generators produce direct current (DC) while alternators produce alternating current (AC).
Generators use a commutator and brushes to convert mechanical energy into electrical energy, while alternators use slip rings and brushes.
Generators are typically used in small-scale applications, such as portable powe...read more
Q4. What are the specifications for a 33 kV transmission line, and how can one select the appropriate specifications?
Specifications for a 33 kV transmission line and how to select appropriate specifications
Specifications for a 33 kV transmission line include conductor size, insulation type, tower height, and distance between towers
Conductor size should be chosen based on current carrying capacity and voltage drop considerations
Insulation type should be selected based on environmental conditions and required insulation levels
Tower height and distance between towers depend on terrain, span le...read more
Q5. How will you analyse the total consumption of diesel in equipment
To analyse total diesel consumption in equipment, I would gather data on usage and calculate fuel efficiency.
Collect data on equipment usage and fuel consumption
Calculate fuel efficiency by dividing fuel consumption by equipment usage
Compare fuel efficiency across different equipment to identify outliers
Identify factors that may affect fuel efficiency, such as maintenance or operator behavior
Q6. What are the tests conducted on power transformers and their applications?
Tests conducted on power transformers include insulation resistance test, turns ratio test, and power factor test.
Insulation resistance test checks the insulation of the transformer windings.
Turns ratio test verifies the turns ratio between primary and secondary windings.
Power factor test measures the efficiency of the transformer in converting power.
Other tests include winding resistance test, transformer oil testing, and temperature rise test.
Q7. Taye of a transfarmar and inverter pv arya mms work and testing
The question is asking about the work and testing of a transformer, inverter, PV array, and MMS in an electrical engineering context.
Transfomer: Explain the function of a transformer in electrical systems, mention testing methods like turns ratio test and insulation resistance test.
Inverter: Describe how an inverter converts DC power to AC power, discuss testing procedures such as efficiency testing and harmonic distortion analysis.
PV Array: Explain the role of a PV array in ...read more
Q8. What is relay coordination in electrical systems?
Relay coordination in electrical systems is the process of ensuring that protective relays operate in a coordinated manner to isolate faults while minimizing disruption to the system.
Relay coordination involves setting time-current curves for protective relays to ensure that the relay closest to the fault operates first.
It is important to coordinate relays to prevent unnecessary tripping of healthy equipment during a fault.
Proper relay coordination helps maintain system stabi...read more
Q9. What the reason of cube failure, if all materials are good?
Possible reasons for cube failure despite good materials
Improper mixing of materials
Incorrect curing process
Inadequate compaction of concrete
Presence of air voids or impurities
Poor quality control during manufacturing
Q10. Brief discussion about the is code of practice for steel structure
IS code of practice for steel structures is a set of guidelines and standards for designing and constructing steel structures.
The IS code for steel structures in India is IS 800:2007.
It covers various aspects such as material properties, design criteria, construction practices, and quality control.
The code provides guidelines for the design of steel structures to ensure safety, efficiency, and durability.
It is important for engineers and architects to adhere to these codes to...read more
Q11. Tell Me about solar equipment which are use in solar and wind energy plant.
Solar equipment used in solar and wind energy plants include solar panels, inverters, batteries, and wind turbines.
Solar panels are used to convert sunlight into electricity.
Inverters are used to convert the direct current (DC) produced by solar panels into alternating current (AC) for use in electrical systems.
Batteries are used to store excess energy generated by solar panels or wind turbines for later use.
Wind turbines are used to convert wind energy into electricity.
Other...read more
Q12. Test of concrete, it's characteristics regards structure
Concrete is a composite material made of cement, water, aggregates, and often admixtures. It has high compressive strength but low tensile strength.
Concrete is a mixture of cement, water, and aggregates like sand and gravel
It has high compressive strength, making it suitable for structural applications
However, it has low tensile strength, which can lead to cracking under tension
Reinforcement like steel bars can be added to improve tensile strength, creating reinforced concret...read more
Q13. What is the conversion process in karnataka
The conversion process in Karnataka refers to the process of changing land use from agricultural to non-agricultural purposes.
Conversion process involves obtaining permission from the concerned authorities.
Applicants need to submit relevant documents and pay the necessary fees.
The process may vary based on the specific location and type of land.
Examples include converting agricultural land into residential or commercial use.
Q14. How many Quantity of cement use in M35 grade concrete
The quantity of cement used in M35 grade concrete varies depending on the mix design and specifications.
The quantity of cement in M35 grade concrete typically ranges from 360 to 420 kg/m3.
The exact amount of cement needed can be calculated using the mix design provided for the project.
Factors such as water-cement ratio, aggregate size, and admixtures also influence the quantity of cement required.
Q15. Brief acknowledgement about the total station
Total station is a surveying instrument used for measuring angles and distances in surveying and construction.
Total station combines theodolite, electronic distance meter, and software to measure angles and distances accurately.
It is commonly used in construction, civil engineering, and land surveying.
Total station can be used for setting out buildings, roads, and other infrastructure projects.
It provides precise measurements for mapping, topography, and monitoring purposes.
Q16. Electrical AC Dc work field in electrical work
Electrical AC DC work field involves working with both alternating current (AC) and direct current (DC) in electrical systems.
AC (alternating current) is the type of electrical current commonly used in homes and businesses, while DC (direct current) is used in batteries and electronic devices.
AC current periodically changes direction, while DC current flows in only one direction.
In electrical work, understanding and working with both AC and DC currents is essential for troubl...read more
Q17. What is the use of winch machine
A winch machine is used for lifting or pulling heavy objects using a motor-driven cable or rope.
Used in construction for lifting heavy materials
Commonly used in off-road vehicles for recovery purposes
Found on boats for raising and lowering anchors
Can be used in forestry for dragging logs
Q18. Tell me about solar and wind energy?
Solar and wind energy are renewable sources of power that harness the sun and wind to generate electricity.
Solar energy is generated by converting sunlight into electricity using solar panels.
Wind energy is generated by using wind turbines to convert the kinetic energy of the wind into electricity.
Both solar and wind energy are clean and sustainable alternatives to fossil fuels.
Solar and wind energy systems can be used for residential, commercial, and industrial purposes.
Exam...read more
Q19. How many amounts deducted in EPS per month per month
The amount deducted in EPS per month varies based on the employee's salary and age.
The EPS deduction is 12% of the employee's basic salary and DA.
Employees above the age of 58 are exempt from EPS deductions.
The maximum EPS deduction per month is Rs. 1,250.
The minimum EPS deduction per month is Rs. 250.
Employers also contribute 8.33% of the employee's basic salary and DA towards EPS.
Q20. Which device to use for testing insulation?
A megohmmeter is used for testing insulation.
A megohmmeter, also known as an insulation tester, is used to measure the resistance of insulation materials.
It applies a high voltage to the insulation and measures the current flowing through it.
The results help determine if the insulation is in good condition or if there are any faults or leaks.
Megohmmeters are commonly used in electrical and electronic industries to ensure the safety and reliability of insulation.
Examples of in...read more
Q21. Which test conduct after cube test?
Compression test is conducted after cube test to determine the compressive strength of concrete.
Compression test is conducted to determine the compressive strength of concrete.
It involves applying a gradually increasing load to the concrete specimen until failure.
The results of the compression test help in assessing the quality of the concrete mix and its ability to withstand compressive forces.
Compression test is an important test in construction projects to ensure the struc...read more
Q22. How to talk friendly with customer?
Talking friendly with customers requires active listening, positive language, empathy, and a willingness to help.
Use positive language and avoid negative words or phrases
Listen actively to the customer's concerns and show empathy
Be patient and avoid interrupting the customer
Offer solutions or alternatives to the customer's problem
Thank the customer for their business and offer assistance in the future
Use the customer's name to personalize the conversation
Q23. Electrical work in solar energy
Electrical work in solar energy involves designing, installing, and maintaining electrical systems for solar power generation.
Designing and sizing solar power systems
Installing solar panels and inverters
Connecting solar panels to the electrical grid
Troubleshooting and repairing electrical issues in solar systems
Performing regular maintenance and inspections
Ensuring compliance with safety regulations and standards
Q24. What is the 164 notification
The 164 notification is a notification sent by a system to alert users of a specific event or action.
The 164 notification typically includes important information or updates that users need to be aware of.
It can be triggered by various events such as system errors, completed tasks, or new messages.
Users may receive the 164 notification through email, text message, or within the system itself.
Q25. Testing of equipments
Testing of equipments involves ensuring they are functioning properly and meet safety standards.
Regularly inspect equipment for any signs of damage or wear
Conduct performance tests to ensure equipment is functioning as expected
Calibrate equipment regularly to maintain accuracy
Follow manufacturer's guidelines for testing and maintenance
Keep detailed records of testing and maintenance activities
Train staff on proper use and testing procedures
Examples: Testing a fire alarm syste...read more
Q26. What is a batal proces
A batal process is a term used in the oil and gas industry to describe a process where two fluids are mixed together to create a desired outcome.
Batal processes are commonly used in drilling operations to create drilling mud with specific properties.
The mixing of drilling mud involves combining water, clay, and other additives to achieve the desired viscosity and density.
Batal processes can also be used in hydraulic fracturing operations to create fracturing fluids with speci...read more
Q27. What is the S.O.P ?
S.O.P stands for Standard Operating Procedure, which is a set of step-by-step instructions compiled by an organization to help workers carry out routine operations.
S.O.P outlines the steps that employees should take to complete a specific task or process.
It ensures consistency and quality in the performance of tasks.
S.O.Ps are used in various industries such as manufacturing, healthcare, and food service.
For example, in a manufacturing plant, there may be an S.O.P for machine...read more
Q28. Lapping zone in column
Lapping zone in column refers to the area where the stationary phase and mobile phase meet in chromatography.
The lapping zone is where the sample components interact with the stationary phase and mobile phase.
It is important for separation efficiency and resolution in chromatography.
Examples include the interface between the liquid and solid phases in column chromatography.
Q29. What is the S.T.Q ?
S.T.Q stands for Safety, Time, Quality - a framework used in production engineering to prioritize aspects of a project.
Safety: Ensuring that all processes and equipment are safe for workers and the environment.
Time: Managing the schedule and deadlines to ensure timely completion of projects.
Quality: Maintaining high standards of quality in the production process and final products.
Example: Prioritizing safety measures before starting a new production line.
Example: Setting rea...read more
Q30. How is the Creating of MIS
MIS creation involves gathering, analyzing, and presenting data to support decision-making.
MIS involves collecting data from various sources such as databases, spreadsheets, and reports.
The data is then analyzed to identify trends, patterns, and insights.
The analyzed data is presented in the form of reports, dashboards, and visualizations to aid decision-making.
Examples of MIS include sales reports, inventory tracking systems, and financial performance dashboards.
Q31. How to deals with customer?
Dealing with customers requires active listening, empathy, and problem-solving skills.
Listen actively to the customer's concerns and needs
Show empathy and understanding towards their situation
Offer solutions and options to resolve their issue
Follow up with the customer to ensure their satisfaction
Maintain a positive and professional attitude throughout the interaction
Q32. What is Jsa & What is Hira.
JSA stands for Job Safety Analysis, a process of identifying potential hazards in a job task. HIRA stands for Hazard Identification and Risk Assessment, a systematic approach to identifying and managing risks.
JSA involves breaking down a job task into steps, identifying potential hazards at each step, and implementing controls to mitigate the risks.
HIRA involves identifying hazards, assessing the associated risks, and implementing measures to control or eliminate the risks.
Bo...read more
Q33. Knowledge in operation of SAP
I have extensive knowledge in the operation of SAP.
I have experience in using various modules of SAP such as FI/CO, MM, and SD.
I am proficient in creating and modifying reports using SAP Query and ABAP programming.
I have experience in configuring and customizing SAP to meet business requirements.
I have trained end-users on how to use SAP and provided support when needed.
Q34. Per MW cost with rational?
Per MW cost with rational refers to the cost of generating one megawatt of electricity with a logical and reasonable approach.
Per MW cost with rational is calculated by taking into account all the expenses incurred in generating one megawatt of electricity.
This includes the cost of fuel, maintenance, labor, and other operational expenses.
The cost can vary depending on the type of power plant, fuel source, and location.
For example, the per MW cost with rational for a coal-fire...read more
Q35. What a knowledge about store
Knowledge about store involves managing inventory, organizing goods, ensuring proper storage conditions, and maintaining accurate records.
Managing inventory levels to prevent stockouts or overstocking
Organizing goods in a systematic manner for easy access
Ensuring proper storage conditions to maintain product quality
Maintaining accurate records of incoming and outgoing goods
Implementing inventory control measures to prevent theft or loss
Q36. Cell manufacturing process
Cell manufacturing process involves the production of cells for various applications such as tissue engineering and regenerative medicine.
Cell manufacturing process involves the culture and expansion of cells in a controlled environment.
Cells are typically grown in bioreactors or cell culture flasks with specific growth media and conditions.
The process may include cell isolation, cell expansion, differentiation, and quality control steps.
Examples include the production of ste...read more
Q37. How land acquisition works?
Q38. What is UA/UC
UA/UC stands for Unsafe Acts/Unsafe Conditions, which are factors contributing to accidents in the workplace.
UA refers to unsafe acts, which are actions or behaviors that increase the risk of accidents (e.g. not wearing proper PPE, horseplay)
UC refers to unsafe conditions, which are environmental factors that increase the risk of accidents (e.g. faulty equipment, poor lighting)
Identifying and addressing UA/UC is crucial in preventing workplace accidents and promoting safety
Q39. Preferred location
I am open to opportunities in various locations, with a preference for urban areas with good public transportation.
Open to various locations
Preference for urban areas
Good public transportation is a plus
Q40. What is near miss
A near miss is an unplanned event that did not result in injury, illness, or damage, but had the potential to do so.
Near misses are incidents that could have resulted in harm, but by chance did not.
They are important to report and investigate to prevent future accidents.
Examples include a tool falling from height but narrowly missing a worker, or a vehicle swerving to avoid a collision.
Top HR Questions asked in Rimini Street
Interview Process at Rimini Street
Top Interview Questions from Similar Companies
Reviews
Interviews
Salaries
Users/Month