Upload Button Icon Add office photos

Filter interviews by

Clear (1)

Adani Electricity Junior Engineer Electrical Interview Questions and Answers

Updated 14 Nov 2024

Adani Electricity Junior Engineer Electrical Interview Experiences

1 interview found

Junior Engineer Electrical Interview Questions & Answers

user image THAKOR KISHANJI VIJAYJI

posted on 18 Sep 2024

Interview experience
5
Excellent
Difficulty level
Hard
Process Duration
Less than 2 weeks
Result
Selected Selected

I applied via Naukri.com and was interviewed in May 2024. There were 2 interview rounds.

Interview Preparation Tips

Interview preparation tips for other job seekers - Thakur Kishan ji Vijay ji

Interview questions from similar companies

I appeared for an interview in Dec 2016.

Interview Questionnaire 

3 Questions

  • Q1. Tell me about yourself
  • Ans. 

    I am a dedicated and hardworking electrical engineer with experience in designing and implementing electrical systems.

    • I have a Bachelor's degree in Electrical Engineering from XYZ University

    • I have worked on various projects involving the design and installation of electrical systems

    • I am proficient in using software such as AutoCAD and MATLAB for electrical design and analysis

    • I have experience in troubleshooting and rep...

  • Answered by AI
  • Q2. How do communications occurs through power lines
  • Ans. 

    Communications through power lines occur using a technology called Power Line Communication (PLC).

    • Power Line Communication (PLC) is a technology that allows data to be transmitted over existing power lines.

    • PLC uses the frequency range of the power lines to carry data signals.

    • Modulation techniques are used to encode the data onto the power line signals.

    • PLC can be used for various applications such as smart grid systems,...

  • Answered by AI
  • Q3. Function of dampers
  • Ans. 

    Dampers are used to control airflow and regulate temperature in HVAC systems.

    • Dampers are used in HVAC systems to control the flow of air and regulate temperature.

    • They can be manually or automatically operated.

    • They can be used to isolate areas of a building for fire safety purposes.

    • Dampers can also be used in industrial settings to control the flow of gases.

    • Examples of dampers include butterfly dampers, louver dampers,

  • Answered by AI

Interview Preparation Tips

Round: Test
Duration: 1 hour
Total Questions: 60

College Name: Birla Vishvakarma Mahavidyalaya (BVM) Engineering College

I applied via Campus Placement and was interviewed in Jun 2022. There was 1 interview round.

Interview Preparation Tips

Topics to prepare for Tata Power Junior Engineer Electrical interview:
  • Transformers
Interview preparation tips for other job seekers - This job for your luck.............................

Interview Preparation Tips

Interview preparation tips for other job seekers - Don't give short answer but give detailed information for a question, don't leave anything for cross question.
Interview experience
5
Excellent
Difficulty level
Moderate
Process Duration
Less than 2 weeks
Result
Selected Selected

I applied via Naukri.com and was interviewed before Mar 2023. There was 1 interview round.

Interview Preparation Tips

Topics to prepare for Reliance Power Manager interview:
  • Electrical system
Interview experience
4
Good
Difficulty level
Moderate
Process Duration
4-6 weeks
Result
Selected Selected

I applied via LinkedIn and was interviewed in Feb 2023. There were 2 interview rounds.

Interview Preparation Tips

Interview preparation tips for other job seekers - Show good attitude, decent to good understanding of field of work, know basics of work.

I applied via Recruitment Consultant and was interviewed in Dec 2021. There was 1 interview round.

Interview Questionnaire 

10 Questions

  • Q1. Why transformer are rated in KVA.
  • Ans. 

    Transformers are rated in KVA because it represents the apparent power they can handle.

    • KVA stands for kilovolt-ampere, which is a unit of apparent power.

    • Transformers are designed to handle a certain amount of power, and the KVA rating indicates their capacity.

    • The KVA rating takes into account both the voltage and current that the transformer can handle.

    • It helps in determining the appropriate size and capacity of the tr...

  • Answered by AI
  • Q2. What is the ground clearance of 400KV transmission line.
  • Ans. 

    The ground clearance of a 400KV transmission line varies depending on various factors.

    • The ground clearance of a transmission line is the vertical distance between the lowest point of the conductor and the ground.

    • The ground clearance is determined based on safety regulations and requirements.

    • Factors that influence the ground clearance include terrain, vegetation, and proximity to buildings or roads.

    • In hilly areas, the g...

  • Answered by AI
  • Q3. What should be the tan Delta value of electrical equipment (for example T/F).
  • Ans. 

    The tan Delta value of electrical equipment should be as low as possible.

    • Tan Delta is a measure of the dielectric losses in electrical equipment.

    • A low tan Delta value indicates that the equipment has good insulation properties.

    • The tan Delta value can be affected by factors such as temperature, moisture, and aging of the equipment.

    • For transformers, a typical tan Delta value is around 0.001 or lower.

  • Answered by AI
  • Q4. Why ACSRinvar conductor are widely used in metro principal city.
  • Ans. 

    ACSRinvar conductors are widely used in metro principal cities due to their high strength and low thermal expansion.

    • ACSRinvar conductors have a high tensile strength, making them suitable for long-distance transmission lines in metro cities.

    • They have a low coefficient of thermal expansion, which helps in reducing sagging of the conductors and maintaining power transmission efficiency.

    • The use of ACSRinvar conductors in ...

  • Answered by AI
  • Q5. The Basis setting of REF protectionfor transformer should be how much.
  • Ans. 

    The Basis setting of REF protection for a transformer should be determined based on the transformer's characteristics and the system requirements.

    • The basis setting of REF (Restricted Earth Fault) protection for a transformer is typically determined by considering the transformer's winding configuration, impedance, and the system's fault level.

    • The setting should be chosen to ensure that the protection operates reliably ...

  • Answered by AI
  • Q6. The SF6 gas used for Ckt breaker chamber should be how much bar.
  • Ans. 

    The SF6 gas used for Ckt breaker chamber should be maintained at a pressure of around 5-7 bar.

    • The SF6 gas in the circuit breaker chamber should be maintained at a specific pressure to ensure proper functioning.

    • The recommended pressure for SF6 gas in the circuit breaker chamber is typically between 5 and 7 bar.

    • Maintaining the correct pressure helps in extinguishing the arc during circuit interruption.

    • Too low or too high...

  • Answered by AI
  • Q7. Why star star zero phase shift transformer winding are used.
  • Ans. 

    Star-star zero phase shift transformer windings are used to provide a balanced three-phase output with zero phase shift between primary and secondary voltages.

    • Star-star zero phase shift transformer windings are commonly used in power distribution systems.

    • They are used to supply power to three-phase loads such as motors, generators, and transformers.

    • The windings are designed in such a way that the voltages in the primar...

  • Answered by AI
  • Q8. What are the main difference between AIS and GIS Substation.
  • Ans. 

    AIS and GIS substations differ in their construction and insulation methods.

    • AIS (Air Insulated Substation) uses air as the insulation medium, while GIS (Gas Insulated Substation) uses SF6 gas.

    • AIS substations require larger land areas compared to GIS substations.

    • GIS substations are more compact and can be installed in urban areas where space is limited.

    • AIS substations are more susceptible to environmental factors like p...

  • Answered by AI
  • Q9. Why vibration damper are used with Conductor.
  • Ans. 

    Vibration dampers are used with conductors to reduce the risk of fatigue failure and damage caused by wind-induced vibrations.

    • Vibration dampers absorb and dissipate the energy generated by wind-induced vibrations in conductors.

    • They help to reduce the risk of fatigue failure and damage to the conductor and associated hardware.

    • Vibration dampers are typically installed at regular intervals along the length of the conducto...

  • Answered by AI
  • Q10. What is main function of LA in Substion.
  • Ans. 

    The main function of LA in a substation is to protect electrical equipment from lightning strikes.

    • LA stands for Lightning Arrester.

    • It is installed in substations to divert lightning strikes away from sensitive equipment.

    • LA provides a low-impedance path for lightning current to flow to the ground.

    • It helps in preventing damage to transformers, circuit breakers, and other electrical devices.

    • LA operates by ionizing the air...

  • Answered by AI

Interview Preparation Tips

Interview preparation tips for other job seekers - As per my point of view the interview for Electrical Experience Engineer/Manager should be on behalf of Experience and technical topics.
Interview experience
5
Excellent
Difficulty level
-
Process Duration
-
Result
-
Interview experience
4
Good
Difficulty level
Moderate
Process Duration
6-8 weeks
Result
Selected Selected

I applied via Approached by Company

Interview experience
5
Excellent
Difficulty level
Moderate
Process Duration
4-6 weeks
Result
Selected Selected

I applied via Company Website and was interviewed in May 2024. There were 2 interview rounds.

Round 1 - Technical 

(2 Questions)

  • Q1. Related PTR questions
  • Q2. Control panel releted
Round 2 - HR 

(2 Questions)

  • Q1. Why u change job
  • Ans. 

    Seeking new challenges and opportunities for growth in a different work environment.

    • Desire for career advancement

    • Seeking new challenges

    • Change in work environment

    • Opportunity for personal growth

  • Answered by AI
  • Q2. Payment expectations

Interview Preparation Tips

Interview preparation tips for other job seekers - Good company for future endeavours
Contribute & help others!
anonymous
You can choose to be anonymous

Adani Electricity Interview FAQs

How many rounds are there in Adani Electricity Junior Engineer Electrical interview?
Adani Electricity interview process usually has 2 rounds. The most common rounds in the Adani Electricity interview process are Aptitude Test and Technical.
What are the top questions asked in Adani Electricity Junior Engineer Electrical interview?

Some of the top questions asked at the Adani Electricity Junior Engineer Electrical interview -

  1. Torrent power 1 year experie...read more
  2. Diploma electrical engin...read more
  3. Diploma electrical CGPA =...read more

Recently Viewed

INTERVIEWS

Adani Electricity

No Interviews

SALARIES

LM Wind Power

SALARIES

Bajaj Energy

INTERVIEWS

Adani Electricity

No Interviews

INTERVIEWS

Adani Electricity

No Interviews

INTERVIEWS

Renewsys India

5.6k top interview questions

SALARIES

Sudhir Power

REVIEWS

Simpa Energy

No Reviews

SALARIES

Bajaj Energy

No Salaries

SALARIES

Adani Electricity

Tell us how to improve this page.

Adani Electricity Junior Engineer Electrical Interview Process

based on 1 interview

Interview experience

5
  
Excellent
View more

Interview Questions from Similar Companies

Adani Power Interview Questions
3.9
 • 218 Interviews
Tata Power Interview Questions
3.9
 • 162 Interviews
NTPC Interview Questions
4.2
 • 158 Interviews
Torrent Power Interview Questions
3.7
 • 126 Interviews
ReNew Interview Questions
4.2
 • 87 Interviews
Vestas Interview Questions
4.2
 • 83 Interviews
Jakson Group Interview Questions
4.3
 • 78 Interviews
Siemens Energy Interview Questions
4.1
 • 73 Interviews
View all
Adani Electricity Junior Engineer Electrical Salary
based on 6 salaries
₹2.7 L/yr - ₹7.5 L/yr
51% more than the average Junior Engineer Electrical Salary in India
View more details

Adani Electricity Junior Engineer Electrical Reviews and Ratings

based on 1 review

4.0/5

Rating in categories

4.0

Skill development

5.0

Work-life balance

3.0

Salary

5.0

Job security

4.0

Company culture

3.0

Promotions

3.0

Work satisfaction

Explore 1 Review and Rating
Senior Executive
89 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Senior Manager
82 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Deputy General Manager
60 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Junior Engineer
44 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Assistant Manager
39 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Explore more salaries
Compare Adani Electricity with

Tata Power

3.9
Compare

Reliance Power

4.1
Compare

CESC

3.8
Compare

Torrent Power

3.7
Compare
Did you find this page helpful?
Yes No
write
Share an Interview