  • Q1. Why transformer are rated in KVA.
  • Ans. 

    Transformers are rated in KVA because it represents the apparent power they can handle.

    • KVA stands for kilovolt-ampere, which is a unit of apparent power.

    • Transformers are designed to handle a certain amount of power, and the KVA rating indicates their capacity.

    • The KVA rating takes into account both the voltage and current that the transformer can handle.

    • It helps in determining the appropriate size and capacity of the tr...

  • Answered by AI
  • Q2. What is the ground clearance of 400KV transmission line.
  • Ans. 

    The ground clearance of a 400KV transmission line varies depending on various factors.

    • The ground clearance of a transmission line is the vertical distance between the lowest point of the conductor and the ground.

    • The ground clearance is determined based on safety regulations and requirements.

    • Factors that influence the ground clearance include terrain, vegetation, and proximity to buildings or roads.

    • In hilly areas, the g...

  • Answered by AI
  • Q3. What should be the tan Delta value of electrical equipment (for example T/F).
  • Ans. 

    The tan Delta value of electrical equipment should be as low as possible.

    • Tan Delta is a measure of the dielectric losses in electrical equipment.

    • A low tan Delta value indicates that the equipment has good insulation properties.

    • The tan Delta value can be affected by factors such as temperature, moisture, and aging of the equipment.

    • For transformers, a typical tan Delta value is around 0.001 or lower.

  • Answered by AI
  • Q4. Why ACSRinvar conductor are widely used in metro principal city.
  • Ans. 

    ACSRinvar conductors are widely used in metro principal cities due to their high strength and low thermal expansion.

    • ACSRinvar conductors have a high tensile strength, making them suitable for long-distance transmission lines in metro cities.

    • They have a low coefficient of thermal expansion, which helps in reducing sagging of the conductors and maintaining power transmission efficiency.

    • The use of ACSRinvar conductors in ...

  • Answered by AI
  • Q5. The Basis setting of REF protectionfor transformer should be how much.
  • Ans. 

    The Basis setting of REF protection for a transformer should be determined based on the transformer's characteristics and the system requirements.

    • The basis setting of REF (Restricted Earth Fault) protection for a transformer is typically determined by considering the transformer's winding configuration, impedance, and the system's fault level.

    • The setting should be chosen to ensure that the protection operates reliably ...

  • Answered by AI
  • Q6. The SF6 gas used for Ckt breaker chamber should be how much bar.
  • Ans. 

    The SF6 gas used for Ckt breaker chamber should be maintained at a pressure of around 5-7 bar.

    • The SF6 gas in the circuit breaker chamber should be maintained at a specific pressure to ensure proper functioning.

    • The recommended pressure for SF6 gas in the circuit breaker chamber is typically between 5 and 7 bar.

    • Maintaining the correct pressure helps in extinguishing the arc during circuit interruption.

    • Too low or too high...

  • Answered by AI
  • Q7. Why star star zero phase shift transformer winding are used.
  • Ans. 

    Star-star zero phase shift transformer windings are used to provide a balanced three-phase output with zero phase shift between primary and secondary voltages.

    • Star-star zero phase shift transformer windings are commonly used in power distribution systems.

    • They are used to supply power to three-phase loads such as motors, generators, and transformers.

    • The windings are designed in such a way that the voltages in the primar...

  • Answered by AI
  • Q8. What are the main difference between AIS and GIS Substation.
  • Ans. 

    AIS and GIS substations differ in their construction and insulation methods.

    • AIS (Air Insulated Substation) uses air as the insulation medium, while GIS (Gas Insulated Substation) uses SF6 gas.

    • AIS substations require larger land areas compared to GIS substations.

    • GIS substations are more compact and can be installed in urban areas where space is limited.

    • AIS substations are more susceptible to environmental factors like p...

  • Answered by AI
  • Q9. Why vibration damper are used with Conductor.
  • Ans. 

    Vibration dampers are used with conductors to reduce the risk of fatigue failure and damage caused by wind-induced vibrations.

    • Vibration dampers absorb and dissipate the energy generated by wind-induced vibrations in conductors.

    • They help to reduce the risk of fatigue failure and damage to the conductor and associated hardware.

    • Vibration dampers are typically installed at regular intervals along the length of the conducto...

  • Answered by AI
  • Q10. What is main function of LA in Substion.
  • Ans. 

    The main function of LA in a substation is to protect electrical equipment from lightning strikes.

    • LA stands for Lightning Arrester.

    • It is installed in substations to divert lightning strikes away from sensitive equipment.

    • LA provides a low-impedance path for lightning current to flow to the ground.

    • It helps in preventing damage to transformers, circuit breakers, and other electrical devices.

    • LA operates by ionizing the air...

  • Answered by AI

Interview Preparation Tips

Interview preparation tips for other job seekers - As per my point of view the interview for Electrical Experience Engineer/Manager should be on behalf of Experience and technical topics.
Interview experience
4
Good
Difficulty level
Moderate
Process Duration
6-8 weeks
Result
Selected Selected

I applied via Approached by Company

Interview experience
5
Excellent
Difficulty level
-
Process Duration
-
Result
-

Interview Preparation Tips

Interview preparation tips for other job seekers - Not bad. Better to go for other companies where the job is secure and had good leadership.
Not good for FTE
Interview experience
5
Excellent
Difficulty level
-
Process Duration
-
Result
-
Interview experience
5
Excellent
Difficulty level
-
Process Duration
-
Result
-
Interview experience
5
Excellent
Difficulty level
-
Process Duration
-
Result
-

Interview Questionnaire 

1 Question

  • Q1. Standards use in CNG, Basic of Natural gas, HCV MCV Operation, Gas Reconcilation procedure
  • Ans. 

    The question is about standards used in CNG, basics of natural gas, HCV MCV operation, and gas reconciliation procedure.

    • CNG standards include ISO 15403, SAE J1616, and ANSI NGV2.

    • Natural gas is composed mainly of methane and is extracted from underground reservoirs.

    • HCV and MCV refer to high and medium calorific value, respectively, and are used to measure the energy content of natural gas.

    • Gas reconciliation procedure in...

  • Answered by AI

Junior Engineer Interview Questions & Answers

Torrent Power user image RISHABH KUMAR KANNOUJIYA

posted on 9 Jan 2024

Interview experience
3
Average
Difficulty level
-
Process Duration
-
Result
-
Contribute & help others!
anonymous
You can choose to be anonymous

Adani Electricity Interview FAQs

How many rounds are there in Adani Electricity Junior Engineer interview?
Adani Electricity interview process usually has 3 rounds. The most common rounds in the Adani Electricity interview process are Aptitude Test, Technical and HR.
What are the top questions asked in Adani Electricity Junior Engineer interview?

Some of the top questions asked at the Adani Electricity Junior Engineer interview -

  1. What is switchgear and its worki...read more
  2. Questions related to transform...read more
  3. Questions related to cable and lo...read more

Recently Viewed

SALARIES

LM Wind Power

SALARIES

Bajaj Energy

INTERVIEWS

Adani Electricity

No Interviews

INTERVIEWS

Adani Electricity

No Interviews

INTERVIEWS

Renewsys India

5.6k top interview questions

SALARIES

Sudhir Power

REVIEWS

Simpa Energy

No Reviews

SALARIES

Bajaj Energy

No Salaries

SALARIES

Adani Electricity

SALARIES

LM Wind Power

Tell us how to improve this page.

Adani Electricity Junior Engineer Interview Process

based on 9 interviews

Interview experience

4.6
  
Excellent
View more
Adani Electricity Junior Engineer Salary
based on 44 salaries
₹2.2 L/yr - ₹6.5 L/yr
19% more than the average Junior Engineer Salary in India
View more details

Adani Electricity Junior Engineer Reviews and Ratings

based on 12 reviews

4.0/5

Rating in categories

3.7

Skill development

3.9

Work-life balance

3.9

Salary

3.8

Job security

4.1

Company culture

3.6

Promotions

3.7

Work satisfaction

Explore 12 Reviews and Ratings
Senior Executive
89 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Senior Manager
82 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Deputy General Manager
60 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Junior Engineer
44 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Assistant Manager
39 salaries
unlock blur

₹0 L/yr - ₹0 L/yr

Explore more salaries
Compare Adani Electricity with

Tata Power

3.9
Compare

Reliance Power

4.1
Compare

CESC

3.8
Compare

Torrent Power

3.7
Compare
Did you find this page helpful?
Yes No
write
Share an Interview