Flow meter accuracy depends on various factors such as type of flow meter, fluid properties, and installation conditions.
The type of flow meter used affects its accuracy. For example, a differential pressure flow meter may have an accuracy of +/- 0.5% of the flow rate, while a magnetic flow meter may have an accuracy of +/- 0.25%.
Fluid properties such as viscosity, density, and conductivity can also affect flow meter a...
I applied via Recruitment Consulltant and was interviewed before Feb 2022. There were 4 interview rounds.
Challanges in job, safety , risk and hazards
Top trending discussions
posted on 24 Jul 2021
posted on 24 Jul 2021
posted on 18 Mar 2025
I appeared for an interview before Mar 2024, where I was asked the following questions.
Enhancing plant efficiency involves optimizing processes, reducing waste, and implementing advanced technologies.
Implement process automation to reduce manual intervention and increase precision.
Utilize predictive maintenance to minimize downtime and extend equipment life.
Adopt energy-efficient technologies, such as variable frequency drives (VFDs) for motors.
Optimize process control systems to improve product quality ...
Optimizing plant efficiency involves enhancing processes, reducing waste, and leveraging technology for better performance.
Implement advanced process control systems to maintain optimal operating conditions.
Conduct regular maintenance and calibration of instruments to ensure accuracy and reliability.
Utilize data analytics to identify inefficiencies and areas for improvement.
Train staff on best practices and new technol...
I plan to guide junior staff through mentorship, structured training, and fostering a collaborative environment for growth.
Establish a mentorship program where I pair junior engineers with experienced staff for hands-on learning.
Conduct regular training sessions on industry standards and best practices, such as safety protocols in instrumentation.
Encourage open communication by creating a safe space for juniors to ask ...
Loading and unloading systems in compressors manage pressure and flow for efficient operation and safety.
Loading refers to the process of bringing the compressor up to its operational capacity.
Unloading is the process of reducing the compressor's load to prevent overpressure.
Common methods include variable speed drives and unloaders that adjust the intake valves.
For example, in a reciprocating compressor, unloading can...
Water treatment plants purify water through various processes to ensure safe drinking water.
1. Screening: Removes large debris like leaves and plastic.
2. Coagulation: Chemicals like alum are added to clump particles together.
3. Sedimentation: Heavy particles settle at the bottom of the tank.
4. Filtration: Water passes through sand and gravel to remove smaller particles.
5. Disinfection: Chlorine or UV light is used to k...
I applied via Company Website and was interviewed in Jun 2021. There were 4 interview rounds.
Star/Delta starter is used to reduce the starting current of a motor.
Star connection provides high starting torque but high starting current
Delta connection provides low starting torque but low starting current
Star/Delta starter uses both connections to reduce starting current and provide sufficient starting torque
Used for large motors to prevent damage to motor and electrical system
CV calculation of control valve involves determining the valve's flow coefficient.
CV is calculated using the formula: CV = Q / (SG * sqrt(dP))
Q is the flow rate, SG is the specific gravity of the fluid, and dP is the pressure drop across the valve.
CV is used to select the appropriate valve size for a given application.
Factors such as valve type, trim size, and pressure drop affect the CV value.
CV calculation is importa...
I applied via Referral and was interviewed in Apr 2021. There were 3 interview rounds.
Relay coordination principle ensures that the protective devices operate in a coordinated manner to isolate the faulted section.
Relay coordination principle is used to ensure that the protective devices operate in a coordinated manner to isolate the faulted section.
It involves selecting the appropriate time-current characteristic curves for the protective devices.
The aim is to ensure that the protective device closest ...
TG protection details with rated setting
TG protection refers to transformer generator protection
Rated setting refers to the maximum allowable current or voltage that the protection system can handle
The protection system should be able to detect and isolate faults in the TG system
The rated setting should be set based on the maximum expected fault current or voltage
The protection system should be regularly tested and mai
NGR function with auto operation
NGR stands for Neutral Grounding Resistor
It is used to limit the fault current in a power system
Auto operation means the NGR is automatically switched on or off based on the system conditions
This helps in protecting the equipment and personnel from damage or harm
Daily maintenance planning schedule involves scheduling and prioritizing maintenance tasks.
Create a list of maintenance tasks
Prioritize tasks based on urgency and importance
Assign tasks to team members
Set deadlines for completion
Regularly review and adjust schedule as needed
I applied via Approached by Company and was interviewed in Jun 2022. There were 5 interview rounds.
I applied via Approached by Company and was interviewed before Sep 2022. There were 4 interview rounds.
based on 4 interviews
2 Interview rounds
based on 23 reviews
Rating in categories
Assistant Manager
600
salaries
| ₹4.5 L/yr - ₹12.8 L/yr |
Deputy Manager
584
salaries
| ₹6.7 L/yr - ₹16 L/yr |
Executive
515
salaries
| ₹2.4 L/yr - ₹7.7 L/yr |
Senior Executive
344
salaries
| ₹3.3 L/yr - ₹10.3 L/yr |
Plant Operator
344
salaries
| ₹1.6 L/yr - ₹5.2 L/yr |
UPL
Coromandel International
PI Industries
Deccan Fine Chemicals