Important points considered during sizing of control valve
Fluid properties such as density, viscosity, and pressure
Flow rate and required pressure drop
Valve type and characteristics (linear, equal percentage, quick opening)
Process conditions and control system requirements
Allowable noise and cavitation levels
Valve sizing equations and calculations
Points to consider during sizing of flowmeter
Fluid type and properties
Flow rate range
Pipe size and material
Accuracy requirements
Installation conditions
Budget constraints
Top trending discussions
I applied via Approached by Company and was interviewed in Jun 2022. There were 5 interview rounds.
posted on 20 Jul 2023
I applied via Recruitment Consulltant and was interviewed before Jul 2022. There were 3 interview rounds.
posted on 17 Sep 2022
I applied via Naukri.com and was interviewed in Aug 2022. There were 2 interview rounds.
posted on 8 Oct 2022
I applied via Newspaper Ad
Instrumentation topics and trouble shooting
I applied via Recruitment Consultant and was interviewed in May 2021. There were 3 interview rounds.
posted on 15 Aug 2023
I applied via Company Website and was interviewed in Jul 2023. There were 3 interview rounds.
posted on 1 Oct 2023
I applied via Referral and was interviewed in Sep 2023. There were 2 interview rounds.
posted on 29 Jan 2025
I appeared for an interview before Jan 2024.
Technical and General aptitude focused on logical reasoning
I applied via Referral and was interviewed in Apr 2021. There were 3 interview rounds.
Relay coordination principle ensures that the protective devices operate in a coordinated manner to isolate the faulted section.
Relay coordination principle is used to ensure that the protective devices operate in a coordinated manner to isolate the faulted section.
It involves selecting the appropriate time-current characteristic curves for the protective devices.
The aim is to ensure that the protective device closest ...
TG protection details with rated setting
TG protection refers to transformer generator protection
Rated setting refers to the maximum allowable current or voltage that the protection system can handle
The protection system should be able to detect and isolate faults in the TG system
The rated setting should be set based on the maximum expected fault current or voltage
The protection system should be regularly tested and mai
NGR function with auto operation
NGR stands for Neutral Grounding Resistor
It is used to limit the fault current in a power system
Auto operation means the NGR is automatically switched on or off based on the system conditions
This helps in protecting the equipment and personnel from damage or harm
Daily maintenance planning schedule involves scheduling and prioritizing maintenance tasks.
Create a list of maintenance tasks
Prioritize tasks based on urgency and importance
Assign tasks to team members
Set deadlines for completion
Regularly review and adjust schedule as needed
based on 2 interviews
Interview experience
based on 1 review
Rating in categories
Assistant Manager
600
salaries
| ₹4.5 L/yr - ₹12.8 L/yr |
Deputy Manager
584
salaries
| ₹6.7 L/yr - ₹16 L/yr |
Executive
515
salaries
| ₹2.4 L/yr - ₹7.7 L/yr |
Senior Executive
344
salaries
| ₹3.3 L/yr - ₹10.3 L/yr |
Plant Operator
344
salaries
| ₹1.6 L/yr - ₹5.2 L/yr |
UPL
Coromandel International
PI Industries
Deccan Fine Chemicals