Filter interviews by
I applied via Job Fair and was interviewed before Jan 2024. There were 2 interview rounds.
Top trending discussions
posted on 25 Jan 2025
I was interviewed in Dec 2024.
posted on 16 Sep 2024
I applied via Naukri.com and was interviewed in Aug 2024. There was 1 interview round.
I applied via Recruitment Consulltant and was interviewed in Aug 2024. There was 1 interview round.
I applied via Company Website
Electrician test and all questions
I applied via Walk-in and was interviewed in Oct 2023. There was 1 interview round.
ELCB stands for Earth Leakage Circuit Breaker and MCB stands for Miniature Circuit Breaker.
ELCB is a safety device used to protect against electrical shock caused by earth faults.
MCB is a type of circuit breaker that automatically switches off electrical circuits during abnormal conditions.
ELCB detects current leakage to earth and disconnects the circuit, while MCB protects against overloads and short circuits.
MCB (Miniature Circuit Breaker) provides overload protection by automatically switching off the circuit when current exceeds the rated capacity.
MCB trips when current exceeds its rated capacity to prevent overheating and potential fire hazards.
Overload protection is essential to protect electrical appliances and wiring from damage.
Examples of MCB overload protection include tripping when too many devices are connected ...
posted on 12 Jul 2024
I applied via Walk-in and was interviewed in Jun 2024. There was 1 interview round.
posted on 29 Oct 2023
There are four types of DG (Diesel Generator) checks: daily, weekly, monthly, and annual.
Daily check involves inspecting fuel levels, oil levels, coolant levels, and battery condition.
Weekly check includes checking for any leaks, testing the battery, and verifying the operation of safety features.
Monthly check involves cleaning the air filter, checking the exhaust system, and testing the automatic transfer switch.
Annua...
There are many types of sensors used in electrical systems, including temperature sensors, pressure sensors, proximity sensors, etc.
Temperature sensors
Pressure sensors
Proximity sensors
Motion sensors
Light sensors
To decide how to work in safety in electrical equipment
One safety hazard in electrical protection is electric shock.
Electric shock can occur when coming into contact with live electrical parts.
Proper grounding and insulation of electrical equipment is essential to prevent electric shock.
Regular maintenance and inspections of electrical systems can help identify potential hazards.
Using personal protective equipment such as insulated gloves and safety goggles can reduce the ...
Single phase and three phase are two types of electrical power distribution systems.
Single phase has one live conductor and one neutral conductor, while three phase has three live conductors and one neutral conductor.
Single phase is commonly used in residential and small commercial applications, while three phase is used in industrial and large commercial applications.
Single phase power supply is suitable for low power...
R, Y, B phases are the three phases of AC power supply. They differ in their phase angle and voltage level.
R phase has a phase angle of 0 degrees and is usually connected to the red wire.
Y phase has a phase angle of 120 degrees and is usually connected to the yellow wire.
B phase has a phase angle of 240 degrees and is usually connected to the blue wire.
The voltage level of each phase is the same, but they are out of ph...
In series, voltage adds up while current remains the same. In parallel, voltage remains the same while current adds up.
In series, batteries are connected end-to-end, positive to negative. In parallel, batteries are connected positive to positive and negative to negative.
Series connection increases voltage but does not increase current. Parallel connection increases current but does not increase voltage.
Series connectio...
Periodic maintenance of batteries is crucial for their longevity and optimal performance.
Check the battery terminals for corrosion and clean them if necessary
Inspect the battery case for any cracks or damage
Ensure that the battery is securely fastened in place
Check the electrolyte level and top up with distilled water if required
Test the battery voltage and recharge if necessary
A faulty battery can be identified by checking its voltage, capacity, and physical appearance.
Check the voltage of the battery using a multimeter
Test the capacity of the battery using a battery tester
Inspect the physical appearance of the battery for any signs of damage or leakage
Check the battery terminals for corrosion or loose connections
Compare the battery's performance to its specifications
FUSE, MCB, ELCB, and RCCB are all electrical protection devices, but they differ in their functions and applications.
FUSE is a simple device that protects electrical circuits from overloading or short-circuiting by melting and breaking the circuit.
MCB (Miniature Circuit Breaker) is an automatic switch that trips and cuts off the power supply when there is an overload or short-circuit.
ELCB (Earth Leakage Circuit Breaker...
A DOL starter is a direct online motor starter that provides full voltage to the motor.
Consists of a contactor, overload relay, and start/stop buttons
The contactor connects the motor to the power supply
The overload relay protects the motor from overloading
The start/stop buttons control the on/off function of the motor
Used for small motors with low starting current
Not suitable for large motors or motors with high starti
based on 1 interview
Interview experience
Civil Site Engineer
5
salaries
| ₹2.2 L/yr - ₹5.2 L/yr |
QA QC Engineer
4
salaries
| ₹2 L/yr - ₹10 L/yr |
Data Entry Operator
4
salaries
| ₹2.2 L/yr - ₹2.7 L/yr |
Ward Boy
4
salaries
| ₹4.1 L/yr - ₹4.1 L/yr |
Project Engineer
3
salaries
| ₹3 L/yr - ₹7 L/yr |
Larsen & Toubro Limited
Tata Projects
Shapoorji Pallonji Group
Hindustan Construction Company