I applied via Company Website and was interviewed in Nov 2022. There were 2 interview rounds.
1 phase energy meter measures power in single phase while 3 phase energy meter measures power in three phases.
1 phase energy meter is used for single phase loads like homes, small offices, etc.
3 phase energy meter is used for three phase loads like industrial motors, large factories, etc.
1 phase energy meter has two wires while 3 phase energy meter has four wires.
1 phase energy meter measures voltage, current, power fa...
Smart meters are advanced energy meters that record energy consumption in real-time and communicate it to the utility company.
Smart meters provide real-time energy consumption data to both the consumer and the utility company.
They can communicate wirelessly or through power lines.
Smart meters can help consumers save money by providing information on energy usage patterns.
They can also help utilities manage energy distr...
CT meter measures current while DT meter measures energy consumption.
CT meter measures the current flowing through a circuit while DT meter measures the energy consumption of a circuit over a period of time.
CT meter is used for protection and control purposes while DT meter is used for billing and energy management purposes.
CT meter is used in high voltage applications while DT meter is used in low voltage applications...
SLD stands for Single Line Diagram, a graphical representation of an electrical system.
It shows the flow of electricity in a system
It includes all the components of the system such as transformers, generators, breakers, etc.
It is used by engineers to design and analyze electrical systems
It is also used for maintenance and troubleshooting purposes
Example: SLD of a power plant or a building's electrical system
I was interviewed in Nov 2021.
Cross functional requirements understanding is crucial for successful system development.
Cross functional requirements understanding involves identifying and addressing the needs of all stakeholders involved in the system development process.
It impacts the system by ensuring that all requirements are met and that the system functions as intended.
Examples of cross functional requirements include usability, security, per...
I applied via Walk-in and was interviewed in Oct 2021. There were 3 interview rounds.
The name of the used oil in a 100kva transformer.
The oil used in transformers is typically mineral oil or synthetic oil.
The oil serves as a coolant and insulator.
The oil must be tested regularly to ensure it is still effective.
Common brands of transformer oil include Shell Diala, ExxonMobil, and Chevron.
The oil must be disposed of properly to avoid environmental damage.
Delta sap is used in pipe earthing to improve the conductivity of the soil.
Delta sap is a natural extract from plants that contains organic acids and minerals.
When mixed with soil, it improves the soil's conductivity and reduces its resistance.
This results in a better grounding system for electrical equipment.
Delta sap is also environmentally friendly and non-toxic.
It is a cost-effective solution for improving the perf
I applied via Referral and was interviewed before Jun 2021. There were 2 interview rounds.
I applied via Recruitment Consultant and was interviewed in Oct 2020. There were 3 interview rounds.
based on 14 reviews
Rating in categories
Assistant Engineer
131
salaries
| ₹1.5 L/yr - ₹3.8 L/yr |
Assistant Manager
96
salaries
| ₹4.8 L/yr - ₹10.5 L/yr |
Engineer
86
salaries
| ₹2.2 L/yr - ₹4.5 L/yr |
Area Sales Manager
86
salaries
| ₹4.1 L/yr - ₹14 L/yr |
Production Engineer
74
salaries
| ₹2.2 L/yr - ₹4.8 L/yr |
Samsung
Xiaomi
Huawei Technologies
Apple