Interlocks are safety mechanisms that prevent equipment from operating under unsafe conditions.
Interlocks are used in various industries to prevent accidents and damage to equipment.
They can be mechanical, electrical, or software-based.
Examples include emergency stop buttons, safety gates, and pressure switches.
Interlocks are designed to be fail-safe, meaning that they will prevent operation even if a component fails.
T...
There are several types of safety measures in electrical engineering.
Electrical safety
Fire safety
Equipment safety
Personal safety
Environmental safety
I applied via Walk-in and was interviewed in Sep 2020. There was 1 interview round.
A star delta starter is a type of motor starter used to reduce the starting current of a motor.
Connect the motor windings in a star configuration for starting
Switch the motor windings to a delta configuration once it reaches a certain speed
Use a contactor and timer to control the switching
Commonly used for large motors to reduce starting current and prevent damage to the motor
Requires knowledge of motor wiring and cont
Power saving refers to reducing energy consumption to conserve resources and reduce costs.
Using energy-efficient appliances and light bulbs
Turning off electronics when not in use
Using power strips to easily turn off multiple devices
Adjusting thermostat settings to reduce heating and cooling
Using renewable energy sources like solar panels
Implementing energy-saving practices in industries and businesses
DG sets have various protection mechanisms to ensure safe and efficient operation.
Overload protection
Short circuit protection
Under/over voltage protection
Over/under frequency protection
Reverse power protection
Earth fault protection
Cooling system protection
Fuel system protection
I applied via Campus Placement and was interviewed before May 2023. There was 1 interview round.
I applied via Walk-in and was interviewed in May 2021. There was 1 interview round.
Control wiring for ACB and VCB involves connecting control circuits to the breaker for proper operation.
Control wiring connects the breaker control circuits to the control panel.
The wiring should be properly sized and insulated.
The wiring should be color-coded for easy identification.
The wiring should be tested for proper operation before energizing the breaker.
Examples of control circuits include trip coil, close coil
Control wiring is read by understanding the symbols and connections on the diagram.
Identify the power source and the load
Understand the symbols used for switches, relays, and other components
Follow the connections and determine the control logic
Check for any safety interlocks or emergency stops
Verify the wiring matches the diagram
I applied via Referral and was interviewed in May 2021. There were 3 interview rounds.
posted on 27 Oct 2023
I applied via Company Website and was interviewed in Sep 2023. There were 2 interview rounds.
A 6.6 kVA switch gear is a type of electrical equipment used for controlling, protecting, and isolating electrical circuits.
Switch gear is used to control the flow of electricity in a circuit
6.6 kVA indicates the power rating of the switch gear
It is important for protecting electrical equipment from overloads and short circuits
I applied via Naukri.com and was interviewed in Jul 2024. There was 1 interview round.
I applied via Walk-in
About your job, location, CTC
I applied via Walk-in and was interviewed in Apr 2023. There were 2 interview rounds.
Construction procedure involves planning, designing, obtaining permits, site preparation, foundation construction, framing, finishing, and inspections.
Planning and designing the project
Obtaining necessary permits
Site preparation and excavation
Foundation construction
Framing and structural work
Installation of utilities and systems
Finishing touches such as painting and flooring
Final inspections and approvals
Beam lapping position refers to the location where two beams overlap or intersect in a structural element.
Beam lapping position is important for ensuring structural integrity and load-bearing capacity.
Common beam lapping positions include end-to-end, side-by-side, and staggered lapping.
Proper beam lapping position is determined by engineering calculations and design specifications.
The tile procedure is a method used in computer graphics to fill a region with a repeating pattern or image.
The tile procedure involves dividing the region into smaller tiles and filling each tile with the desired pattern or image.
It is commonly used in graphic design software to create seamless textures or backgrounds.
The size and shape of the tiles can be adjusted to achieve different visual effects.
Examples of tile ...
based on 1 interview
Interview experience
based on 2 reviews
Rating in categories
Mechanical Engineer
39
salaries
| ₹2.4 L/yr - ₹5 L/yr |
Senior Engineer
34
salaries
| ₹3.1 L/yr - ₹5 L/yr |
Safety Officer
21
salaries
| ₹2.4 L/yr - ₹6.2 L/yr |
Mechanical Maintenance Engineer
19
salaries
| ₹1.8 L/yr - ₹6 L/yr |
Store Incharge
13
salaries
| ₹2 L/yr - ₹3.8 L/yr |
Ramky Infrastructure
McNally Bharat Engineering
Consolidated Construction Consortium
SYSTRA