Filter interviews by
I applied via Recruitment Consulltant and was interviewed in Jun 2024. There were 2 interview rounds.
Design, develop, test, and maintain electrical and instrumentation systems in various industries.
Designing electrical systems for industrial processes
Developing control systems for automation
Testing and troubleshooting instrumentation equipment
Maintaining electrical and instrumentation systems
Collaborating with other engineers and technicians
Ensuring compliance with safety regulations
Providing technical support to oper
What is SWA Cable and what is AWG?
Top trending discussions
posted on 10 Sep 2022
Calibration procedure involves comparing the measurement device with a known standard to ensure accuracy.
Select a known standard with a higher accuracy than the device being calibrated
Perform measurements on the standard and record the readings
Compare the readings with the device being calibrated
Adjust the device if necessary to match the standard
Repeat the process until the readings match within an acceptable range
Hazardous zones are classified based on the likelihood of explosive gas or dust. Protection techniques include explosion-proof equipment and ventilation.
Hazardous zones are classified into Zone 0, Zone 1, and Zone 2 based on the likelihood of explosive gas or dust.
Zone 0 is where explosive gas or dust is present continuously or for long periods of time.
Zone 1 is where explosive gas or dust is likely to occur during nor...
posted on 9 Apr 2023
I applied via Walk-in and was interviewed before Apr 2022. There were 3 interview rounds.
posted on 10 Sep 2022
Calibration procedure involves comparing the measurement device with a known standard to ensure accuracy.
Select a known standard with a higher accuracy than the device being calibrated
Perform measurements on the standard and record the readings
Compare the readings with the device being calibrated
Adjust the device if necessary to match the standard
Repeat the process until the readings match within an acceptable range
Hazardous zones are classified based on the likelihood of explosive gas or dust. Protection techniques include explosion-proof equipment and ventilation.
Hazardous zones are classified into Zone 0, Zone 1, and Zone 2 based on the likelihood of explosive gas or dust.
Zone 0 is where explosive gas or dust is present continuously or for long periods of time.
Zone 1 is where explosive gas or dust is likely to occur during nor...
posted on 9 Apr 2023
I applied via Walk-in and was interviewed before Apr 2022. There were 3 interview rounds.
posted on 25 Mar 2021
MOS stands for Metal Oxide Semiconductor. It is a type of transistor used in electronic devices.
MOS is a type of transistor that is commonly used in electronic devices.
It is made up of a metal gate, oxide insulator, and semiconductor material.
MOS transistors are used in digital circuits, amplifiers, and memory devices.
Examples of MOS-based devices include microprocessors, memory chips, and LCD screens.
An instrument is a device used to measure, control, or regulate physical quantities such as temperature, pressure, flow, or level.
Instruments are used in various industries such as manufacturing, chemical, and oil and gas.
Examples of instruments include thermometers, pressure gauges, flow meters, and level sensors.
Instruments can be analog or digital, and can be operated manually or automatically.
Instrument technicians...
Interview experience
Planning Engineer
10
salaries
| ₹6.2 L/yr - ₹14 L/yr |
Project Engineer Mechanical
7
salaries
| ₹3.9 L/yr - ₹12.4 L/yr |
Construction Management
7
salaries
| ₹24 L/yr - ₹36.2 L/yr |
Instrumentation Technician
6
salaries
| ₹4.5 L/yr - ₹8 L/yr |
Senior Store Keeper
6
salaries
| ₹4.1 L/yr - ₹7.5 L/yr |
Larsen & Toubro Limited
TCS
Reliance Industries
Infosys