Current transformer is used to measure high currents while potential transformer is used to measure high voltages.
Current transformer is a type of instrument transformer that steps down high currents to a lower, measurable value.
It is commonly used in power systems to measure and protect against overcurrents.
Potential transformer is also an instrument transformer that steps down high voltages to a lower, measurable val...
Neutral and earth are two different components of an electrical system.
Neutral wire carries current back to the source in a balanced electrical circuit.
Earth wire is a safety measure to protect against electrical faults and provide a path for current to flow to the ground.
Neutral wire is connected to the center tap of the transformer, while earth wire is connected to the ground.
Neutral wire carries current under normal...
Neutral can be generated by using a transformer or by connecting a neutral conductor to the system.
A transformer can be used to generate a neutral point by connecting the primary winding to a three-phase supply and the secondary winding to a star-connected load.
A neutral conductor can be connected to the system by using a neutral earthing transformer or by connecting a neutral conductor to the neutral point of the tran...
Various tests are performed on transformers to ensure their proper functioning and safety.
Insulation resistance test
Turns ratio test
Winding resistance test
Short circuit test
Open circuit test
Impulse test
Temperature rise test
Dielectric strength test
Partial discharge test
Losses in a transformer are the energy losses that occur during the conversion of electrical energy from one voltage level to another.
There are two main types of losses in a transformer: copper losses and iron losses.
Copper losses, also known as I^2R losses, occur in the transformer windings due to the resistance of the copper wire.
Iron losses, also known as core losses, occur in the transformer core due to hysteresis ...
Top trending discussions
posted on 12 May 2024
posted on 4 Jul 2024
I applied via Naukri.com and was interviewed in Nov 2022. There was 1 interview round.
posted on 18 Jun 2024
I appeared for an interview in Jan 2025.
I applied via Indeed and was interviewed in Mar 2022. There was 1 interview round.
posted on 4 Jun 2022
I applied via Naukri.com and was interviewed before Jun 2021. There were 3 interview rounds.
I applied via Referral and was interviewed before Jul 2021. There were 2 interview rounds.
posted on 11 Oct 2020
based on 2 reviews
Rating in categories
Senior Engineer
22
salaries
| ₹4.4 L/yr - ₹7.6 L/yr |
Electrical Engineer
12
salaries
| ₹2.2 L/yr - ₹4.5 L/yr |
Engineer
12
salaries
| ₹3 L/yr - ₹5.1 L/yr |
Product Specialist
8
salaries
| ₹4 L/yr - ₹6.5 L/yr |
Marketing Engineer
8
salaries
| ₹2.7 L/yr - ₹5.2 L/yr |
IndustryBuying.com
DESIGNCO
Krishi Rasayan Exports
P.N. International