Filter interviews by
Miniature Circuit Breaker (MCB) is a type of circuit breaker that automatically switches off electrical circuits during abnormal conditions.
Types of MCB include single pole MCB, double pole MCB, triple pole MCB, and four pole MCB
MCBs can also be classified based on their breaking capacity, such as B, C, D, and K types
Some examples of MCB manufacturers are Schneider Electric, Siemens, ABB, and Legrand
Top trending discussions
I was interviewed in Jan 2024.
IG stands for Installation Guide, which provides instructions on how to properly install and set up a particular product or system.
IG includes step-by-step instructions for installation
It may also include diagrams or illustrations to aid in the installation process
IG is typically provided by the manufacturer or developer of the product
Following the IG ensures proper installation and functionality of the product
Examples...
FG 250 indicates a specific grade of cast iron alloy.
FG 250 is a type of cast iron alloy used in various industrial applications.
The designation FG 250 typically refers to a specific composition and properties of the alloy.
It is important for site supervisors to be familiar with different alloy designations to ensure proper handling and maintenance of equipment.
Examples of components made from FG 250 alloy include engi
5S is a methodology used to organize a workplace for efficiency and effectiveness by sorting, setting in order, shining, standardizing, and sustaining.
Sort: Remove unnecessary items from the workplace.
Set in order: Organize remaining items in a logical manner.
Shine: Clean and inspect the workplace regularly.
Standardize: Establish standards and procedures for maintaining the workplace.
Sustain: Ensure the 5S system is ma...
Current is the flow of electric charge in a circuit.
Current is measured in Amperes (A)
It is the rate of flow of electric charge
Current flows from high voltage to low voltage
In a series circuit, the current is the same at all points
In a parallel circuit, the total current is the sum of the currents through each branch
Soft starters are preferred over star-delta starters for motor start and run due to their ability to reduce inrush current and provide smoother acceleration.
Soft starters provide a gradual increase in voltage to the motor, reducing inrush current and mechanical stress on the motor.
Star-delta starters provide a sudden increase in voltage, resulting in high inrush current and mechanical stress on the motor.
Soft starters ...
Encoders used in industrial include absolute, incremental, linear, rotary, magnetic, and optical encoders.
Absolute encoders provide a unique code for each position
Incremental encoders provide a pulse output for each position change
Linear encoders measure linear motion
Rotary encoders measure rotational motion
Magnetic encoders use a magnetic field to detect position
Optical encoders use light to detect position
VFD parameters are settings that control the operation of a variable frequency drive.
VFD parameters include frequency, voltage, current, acceleration/deceleration time, and motor overload protection
Frequency parameter determines the speed of the motor
Voltage parameter determines the amount of voltage supplied to the motor
Current parameter determines the amount of current supplied to the motor
Acceleration/deceleration t...
I was interviewed in Jul 2022.
I applied via Job Portal and was interviewed before Oct 2022. There were 3 interview rounds.
I have extensive experience in machine maintenance and troubleshooting, including working on various types of equipment.
Performed regular maintenance checks on machines to ensure optimal performance
Identified and resolved mechanical issues to minimize downtime
Utilized diagnostic tools and equipment to troubleshoot problems
Collaborated with team members to develop preventive maintenance plans
Trained new employees on mac
I applied via Naukri.com and was interviewed in Oct 2020. There was 1 interview round.
I handle customers with patience, empathy, and effective communication.
Listen actively to their concerns and needs
Provide clear and concise information
Offer solutions and alternatives
Remain calm and professional, even in difficult situations
Follow up to ensure satisfaction
The process of tower foundation involves several steps that are carried out day by day.
Day 1: Site preparation and layout survey
Day 2: Excavation for foundation
Day 3: Reinforcement placement
Day 4: Formwork installation
Day 5: Concrete pouring
Day 6: Curing of concrete
Day 7: Removal of formwork
Day 8: Quality inspection and testing
Day 9: Backfilling around the foundation
Day 10: Final inspection and documentation
Cube mould size refers to the dimensions of the mould used to cast concrete cubes for testing.
Cube moulds are typically made of steel or cast iron.
The most common cube mould size used in construction is 150mm x 150mm x 150mm.
Other sizes like 100mm x 100mm x 100mm or 200mm x 200mm x 200mm may also be used depending on the requirements.
Cube moulds have removable base plates to facilitate easy removal of the hardened conc...
Quality points at the pouring time of concrete include proper mix proportions, correct placement, adequate compaction, and appropriate curing.
Proper mix proportions ensure the desired strength and durability of the concrete.
Correct placement involves placing the concrete in the designated location without segregation or excessive bleeding.
Adequate compaction ensures that there are no voids or air pockets in the concret...
Sloped cutting refers to the excavation of soil or rock at an inclined angle to create a slope or incline.
Sloped cutting is commonly used in construction projects to create roadways, railways, or canals on hilly terrains.
It involves removing the excess material from a higher elevation to a lower elevation, forming a sloping surface.
The angle of the slope is determined based on factors such as soil stability, desired gr...
Deputy Manager
1.3k
salaries
| ₹5 L/yr - ₹14.3 L/yr |
Manager
666
salaries
| ₹6.9 L/yr - ₹19 L/yr |
Senior Manager
665
salaries
| ₹8.5 L/yr - ₹28 L/yr |
Assistant Manager
328
salaries
| ₹3.8 L/yr - ₹11.2 L/yr |
Deputy General Manager
306
salaries
| ₹15 L/yr - ₹42.2 L/yr |
Siemens
ABB
Honeywell Automation
Emerson Electric Co.