i
Reliance Industries
Proud winner of ABECA 2025 - AmbitionBox Employee Choice Awards
Filter interviews by
5G towers use varying amounts of power depending on factors such as location, equipment, and network traffic.
Power usage of 5G towers can range from 10-200 watts depending on the specific equipment and location.
Factors such as the number of antennas, frequency bands used, and network traffic can impact power consumption.
For example, a small cell 5G tower in a densely populated urban area may use less power than a ...
The range of a 4G tower typically varies from 5 to 30 miles depending on factors like terrain and obstructions.
Range can be affected by factors such as terrain, weather, and obstructions.
In rural areas with flat terrain, the range can be as far as 30 miles.
In urban areas with tall buildings and obstacles, the range may be limited to 5 miles or less.
48V is used in telecom due to its efficiency, safety, and compatibility with existing infrastructure.
48V DC power systems are more efficient than higher voltage systems, reducing energy consumption and costs.
48V is considered safer than higher voltages, reducing the risk of electrical shock.
48V is compatible with existing telecom infrastructure, making it easier to integrate into networks.
48V is also commonly used...
The voltage of a telecom tower typically ranges from 48V to 400V depending on the equipment and power requirements.
Telecom towers usually operate at a voltage of 48V for low power equipment
High power equipment may require voltages up to 400V for operation
Voltage levels can vary based on the specific telecom tower and its equipment
What people are saying about Reliance Industries
DIT stands for Digital India Programme and it is important in NLD for promoting digital literacy and bridging the digital divide.
DIT is a flagship programme of the Indian government aimed at transforming India into a digitally empowered society and knowledge economy.
It focuses on providing digital infrastructure, digital services, and digital literacy to all citizens of India.
In NLD, DIT is important for promoting...
HDD stands for Hard Disk Drive.
HDD is a data storage device used in computers and laptops.
It consists of one or more rotating disks coated with magnetic material.
Data is stored on the disks using read/write heads that move across the surface.
Examples of HDD brands include Seagate, Western Digital, and Toshiba.
OTDR stands for Optical Time Domain Reflectometer. It is used to test and troubleshoot fiber optic cables.
OTDR sends a pulse of light into the fiber and measures the time and strength of the reflected signal.
It can detect faults such as breaks, bends, and splices in the fiber.
OTDR can also measure the length of the fiber and the attenuation of the signal.
It is commonly used in the telecommunications industry to ma...
Steps of fiber deployment in NLD like HDD DIT BLOWING (SURVEY TO HOTO)
Conduct a survey to identify the best route for fiber deployment
Prepare the route by clearing any obstacles and obtaining necessary permits
Choose the appropriate method of deployment such as HDD, DIT or blowing
Install the fiber optic cables along the chosen route
Perform testing and commissioning to ensure the fiber network is operational
Handover...
The acceptable value of Earth-Neutral voltage is 230V or less.
Earth-Neutral voltage should be measured regularly to ensure safety
Higher voltage can cause electric shock or fire
In some countries, the acceptable value may vary
The torquing value of an M24 bolt depends on various factors such as material, lubrication, and thread condition.
The torquing value can be found in the bolt manufacturer's specifications.
Factors such as material, lubrication, and thread condition can affect the torquing value.
Using a torque wrench is recommended to ensure proper torquing.
Over-torquing can lead to bolt failure, while under-torquing can result in lo...
I applied via Referral
I have over 15 years of experience in senior executive roles across various industries.
Led cross-functional teams to successfully launch new products
Implemented cost-saving initiatives resulting in significant revenue growth
Developed and executed strategic plans to drive business expansion
Managed key client relationships to ensure customer satisfaction
Dynamic Senior Executive with 15+ years in strategic leadership, driving growth and innovation across diverse industries.
Proven track record in leading cross-functional teams to achieve organizational goals, such as increasing revenue by 30% in two years.
Expertise in developing and implementing strategic initiatives that enhance operational efficiency, exemplified by a 25% reduction in costs through process optimizatio...
I come from a close-knit family that values education, support, and shared experiences, which have shaped my personal and professional life.
My parents instilled a strong work ethic in me; my father was an engineer and my mother a teacher, both emphasizing the importance of education.
I have two siblings; my brother is a software developer and my sister is pursuing a career in medicine, showcasing our diverse interests.
F...
The voltage of a telecom tower typically ranges from 48V to 400V depending on the equipment and power requirements.
Telecom towers usually operate at a voltage of 48V for low power equipment
High power equipment may require voltages up to 400V for operation
Voltage levels can vary based on the specific telecom tower and its equipment
A mobile tower typically uses around 3-6 kW of power depending on the number of antennas and equipment installed.
Mobile towers consume power for transmitting and receiving signals.
Power usage can vary based on the number of antennas and equipment installed on the tower.
On average, a mobile tower consumes around 3-6 kW of power.
Some towers may use renewable energy sources like solar panels to reduce power consumption.
48V is used in telecom due to its efficiency, safety, and compatibility with existing infrastructure.
48V DC power systems are more efficient than higher voltage systems, reducing energy consumption and costs.
48V is considered safer than higher voltages, reducing the risk of electrical shock.
48V is compatible with existing telecom infrastructure, making it easier to integrate into networks.
48V is also commonly used in d...
The range of a 4G tower typically varies from 5 to 30 miles depending on factors like terrain and obstructions.
Range can be affected by factors such as terrain, weather, and obstructions.
In rural areas with flat terrain, the range can be as far as 30 miles.
In urban areas with tall buildings and obstacles, the range may be limited to 5 miles or less.
5G towers use varying amounts of power depending on factors such as location, equipment, and network traffic.
Power usage of 5G towers can range from 10-200 watts depending on the specific equipment and location.
Factors such as the number of antennas, frequency bands used, and network traffic can impact power consumption.
For example, a small cell 5G tower in a densely populated urban area may use less power than a macro...
About Fiber network project
I applied via Naukri.com and was interviewed in Feb 2024. There were 2 interview rounds.
General aptitude questions
I applied via Naukri.com and was interviewed in Jun 2023. There were 2 interview rounds.
I applied via Naukri.com and was interviewed before Mar 2023. There was 1 interview round.
I applied via Walk-in and was interviewed before Aug 2022. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in May 2022. There were 2 interview rounds.
The torquing value of an M24 bolt depends on various factors such as material, lubrication, and thread condition.
The torquing value can be found in the bolt manufacturer's specifications.
Factors such as material, lubrication, and thread condition can affect the torquing value.
Using a torque wrench is recommended to ensure proper torquing.
Over-torquing can lead to bolt failure, while under-torquing can result in loose b...
I appeared for an interview before Mar 2024, where I was asked the following questions.
Some of the top questions asked at the Reliance Industries Senior Executive interview -
based on 24 interview experiences
Difficulty level
Duration
based on 340 reviews
Rating in categories
Manager
3.5k
salaries
| ₹9.4 L/yr - ₹17 L/yr |
Assistant Manager
2.8k
salaries
| ₹4 L/yr - ₹9.1 L/yr |
Field Executive
2.8k
salaries
| ₹3.5 L/yr - ₹9.2 L/yr |
Senior Manager
2.6k
salaries
| ₹14 L/yr - ₹26 L/yr |
Deputy Manager
1.2k
salaries
| ₹5.3 L/yr - ₹12.7 L/yr |
Indian Oil Corporation
Shell
Bharat Petroleum
Hindustan Petroleum