Filter interviews by
Dewpoint is the temperature at which air becomes saturated with water vapor, causing condensation to form.
Dewpoint is the temperature at which dew forms on surfaces.
It is a measure of the amount of moisture in the air.
Dewpoint is affected by both temperature and humidity.
When the dewpoint is close to the actual temperature, the air is very humid.
Dewpoint is important in weather forecasting and HVAC systems.
The temperature at which water droplets begin to condense and dew can form is called dew point.
Dew point is the temperature at which the air becomes saturated with water vapor and condensation begins to form.
It varies depending on the amount of moisture in the air.
Dew point is an important factor in weather forecasting and can affect outdoor activities such as camping and hiking.
For example, if the dew point is high, i...
I applied via Campus Placement
I applied via Campus Placement and was interviewed before Jul 2020. There was 1 interview round.
I applied via Approached by Company and was interviewed before May 2021. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Jun 2020. There was 1 interview round.
I applied via Naukri.com and was interviewed before Sep 2021. There were 2 interview rounds.
The covered area of the project is approximately 10,000 square feet.
The covered area includes the indoor space of the project.
It does not include any outdoor space or open areas.
The exact covered area may vary depending on the project.
In this particular project, the covered area is approximately 10,000 square feet.
I applied via Monster
Foxboro iA series DCS is a distributed control system used in industrial automation.
It is designed for process automation and control in industries such as oil and gas, power, and chemical.
It offers advanced control strategies and algorithms for optimizing process performance.
It includes a range of hardware and software components, including controllers, I/O modules, and engineering tools.
It supports various communicat...
Triconex PLC is a safety instrumented system used in critical applications.
Triconex PLC is designed for high availability and fault tolerance.
It uses triple modular redundancy (TMR) architecture to ensure safety and reliability.
It has a wide range of input/output modules and communication options.
It is used in industries such as oil and gas, chemical, and power generation.
It has features such as diagnostics, testing, a...
Spanning Tree Protocol (STP) is a network protocol that prevents loops in a network topology.
STP is used to prevent broadcast storms caused by loops in a network.
It works by selecting a root bridge and disabling redundant paths to prevent loops.
STP is implemented in switches and bridges in a network.
It is defined in IEEE 802.1D standard.
STP has several variants such as Rapid STP (RSTP) and Multiple STP (MSTP).
DCS systems in different plants are interconnected through various communication protocols.
DCS systems use communication protocols like Modbus, Profibus, and Ethernet/IP to interconnect.
Interconnection allows for data sharing and control between different plant areas.
DCS systems can also be connected to other systems like SCADA and MES for higher-level control and monitoring.
Interconnection can be achieved through wire...
Siemens, GE Fanuc, and Allen Bradley PLCs are programmable logic controllers used in industrial automation.
Siemens PLCs are known for their high processing speed and advanced communication capabilities.
GE Fanuc PLCs are known for their flexibility and ability to handle complex applications.
Allen Bradley PLCs are known for their user-friendly programming software and extensive support network.
All three PLCs offer a rang...
Steps to be taken for work in a safety critical loop
Identify the safety critical loop
Define the safety requirements
Design the loop with redundancy and fault tolerance
Implement the loop with safety standards
Test the loop thoroughly
Maintain the loop regularly
I applied via Campus Placement and was interviewed before Dec 2020. There was 1 interview round.
Commissioning Engineer
5
salaries
| ₹0 L/yr - ₹0 L/yr |
IT Project Lead
4
salaries
| ₹0 L/yr - ₹0 L/yr |
Construction Management
4
salaries
| ₹0 L/yr - ₹0 L/yr |
Hsse Advisor
4
salaries
| ₹0 L/yr - ₹0 L/yr |
Commissioning Supervisor
4
salaries
| ₹0 L/yr - ₹0 L/yr |
L&T Energy Hydrocarbon
TechnipFMC
McDermott International
Saipem