Formula for calculating duct area in HVAC engineering.
The formula for calculating duct area is A = (π/4) x D²
A is the area of the duct in square feet
D is the diameter of the duct in feet
π is a mathematical constant approximately equal to 3.14
The formula assumes the duct is circular in shape
Ducts are used to distribute air in HVAC systems. They come in various types and shapes.
Types of ducts include rectangular, round, oval, and flexible.
Rectangular ducts are commonly used in commercial buildings.
Round ducts are more efficient for air flow and are used in residential buildings.
Oval ducts are used in tight spaces where round ducts cannot fit.
Flexible ducts are used for easy installation and can be bent to ...
Insulation types include fiberglass, foam, cellulose, and mineral wool.
Fiberglass insulation is made of tiny glass fibers and is commonly used in residential and commercial buildings.
Foam insulation can be made of polyurethane, polystyrene, or polyisocyanurate and is often used in walls, roofs, and foundations.
Cellulose insulation is made of recycled paper and is blown into walls and attics.
Mineral wool insulation is m...
The thickness of GI sheet varies according to its gauge.
GI sheet thickness is measured in gauge.
The higher the gauge number, the thinner the sheet.
For example, a 20-gauge GI sheet has a thickness of 0.0359 inches.
A 16-gauge GI sheet has a thickness of 0.0598 inches.
posted on 14 May 2022
I applied via Naukri.com and was interviewed before May 2021. There was 1 interview round.
I applied via Walk-in and was interviewed before Apr 2020. There were 5 interview rounds.
I applied via Recruitment Consultant and was interviewed before Sep 2020. There were 3 interview rounds.
I applied via Job Portal and was interviewed before Apr 2021. There was 1 interview round.
Solid principles are a set of design principles for writing maintainable and scalable code in C#.
Single Responsibility Principle (SRP) - a class should have only one reason to change
Open/Closed Principle (OCP) - a class should be open for extension but closed for modification
Liskov Substitution Principle (LSP) - derived classes should be substitutable for their base classes
Interface Segregation Principle (ISP) - client...
I applied via Campus Placement and was interviewed before May 2020. There were 4 interview rounds.
I applied via Naukri.com and was interviewed before Apr 2020. There were 5 interview rounds.
I applied via Campus Placement and was interviewed before Jan 2020. There were 4 interview rounds.
I applied via Campus Placement and was interviewed before May 2020. There were 4 interview rounds.
I applied via Campus Placement and was interviewed before Feb 2020. There were 4 interview rounds.
based on 1 interview
Interview experience
based on 4 reviews
Rating in categories
Project Engineer Hvac
4
salaries
| ₹2.4 L/yr - ₹4.2 L/yr |
Hvac Design Engineer
4
salaries
| ₹3 L/yr - ₹8 L/yr |
Hvac Service Engineer
4
salaries
| ₹2.4 L/yr - ₹3.4 L/yr |
HVAC Design and Estimation Engineer
4
salaries
| ₹4.2 L/yr - ₹9.5 L/yr |
Project Engineer
3
salaries
| ₹2 L/yr - ₹4.3 L/yr |
TCS
Accenture
Wipro
Cognizant