I always prioritize safety when working at heights by following specific precautions.
Wearing appropriate personal protective equipment (PPE) such as safety harnesses, helmets, and non-slip footwear
Using fall protection systems like guardrails, safety nets, or lifelines
Regularly inspecting and maintaining equipment like ladders, scaffolds, and platforms
Ensuring proper training and certification for working at heights
Imp...
5S system is a workplace organization method that aims to improve efficiency and productivity by eliminating waste and optimizing workflow.
5S stands for Sort, Set in Order, Shine, Standardize, and Sustain
Sort involves removing unnecessary items from the workplace
Set in Order involves organizing the remaining items in a logical and efficient manner
Shine involves cleaning and maintaining the workplace
Standardize involves...
Sort Set Shine Standardize Sustain are the 5S principles of workplace organization.
Sort: Remove unnecessary items from the workplace.
Set: Organize the remaining items in a logical manner.
Shine: Clean and maintain the workplace regularly.
Standardize: Establish procedures and standards for maintaining the workplace.
Sustain: Continuously improve and sustain the 5S principles.
Top trending discussions
posted on 27 Jan 2025
posted on 21 Dec 2023
I applied via Company Website and was interviewed in Nov 2023. There were 2 interview rounds.
DOL (Direct-On-Line) and star delta are two different wiring schemes used in electrical engineering for starting induction motors.
DOL wiring directly connects the motor to the power supply for starting, while star delta wiring initially starts the motor in star configuration and then switches to delta configuration for running.
DOL wiring is simpler and cheaper but causes high starting current, while star delta wiring r...
I applied via Approached by Company and was interviewed in Jul 2022. There were 2 interview rounds.
posted on 13 Jul 2021
I applied via Walk-in and was interviewed in Jan 2021. There were 3 interview rounds.
posted on 10 Oct 2020
I applied via Walk-in and was interviewed before Apr 2020. There was 1 interview round.
A transformer is an electrical device that transfers electrical energy from one circuit to another through electromagnetic induction.
Transformers are used to increase or decrease the voltage of an alternating current (AC) power supply.
They consist of two coils of wire, known as the primary and secondary coils, which are wrapped around a magnetic core.
When an AC voltage is applied to the primary coil, it creates a magne...
The type of breaker used depends on the electrical load and the circuit requirements.
The most common types of breakers are standard, AFCI, GFCI, and dual-function.
Standard breakers are used for general-purpose circuits.
AFCI breakers are used for circuits that power bedrooms and living rooms.
GFCI breakers are used for circuits that power bathrooms, kitchens, and outdoor areas.
Dual-function breakers combine AFCI and GFCI...
Conductors are materials that allow electricity to flow through them. There are different types of conductors used in electrical systems.
Copper is the most commonly used conductor in electrical wiring
Aluminum is also used as a conductor, especially in high voltage power transmission
Silver is the best conductor, but it is too expensive for most applications
Gold is also a good conductor, but it is even more expensive tha...
MCB is a miniature circuit breaker while MCCB is a molded case circuit breaker.
MCB is used for low current applications while MCCB is used for high current applications.
MCB is rated up to 100 amps while MCCB can be rated up to 2500 amps.
MCCB has adjustable trip settings while MCB does not.
MCCB is more expensive than MCB.
Examples of MCB brands include Legrand and Schneider while examples of MCCB brands include Siemens a
posted on 16 Jul 2024
I applied via Shine and was interviewed in Jan 2024. There were 3 interview rounds.
Daily maintenance procedures for electrical engineers ensure optimal performance and safety of electrical systems.
Inspecting and testing electrical equipment for any signs of wear or damage
Cleaning and lubricating moving parts to prevent friction and overheating
Checking and replacing faulty components such as fuses or circuit breakers
Calibrating sensors and meters to ensure accurate readings
Updating software and firmwa...
posted on 13 Jan 2022
I was interviewed in Dec 2021.
MGND stands for Main Ground. It refers to the primary grounding point in an electrical system.
MGND is the main grounding point in an electrical system.
It is typically connected to the earth ground to provide a safe path for electrical current to flow in case of a fault.
MGND helps protect equipment and personnel from electrical shocks.
It is an essential component in ensuring electrical safety and proper functioning of t
Grounding negative in inverters helps in reducing electromagnetic interference (EMI) and noise.
Grounding negative in inverters helps in reducing EMI and noise.
It also helps in improving the efficiency of the inverter.
Grounding negative is done to provide a reference point for the inverter's output voltage.
It also helps in protecting the inverter from voltage spikes and surges.
Examples of inverters that use negative gro...
Assistant Manager
54
salaries
| ₹3.5 L/yr - ₹12.5 L/yr |
Engineer
40
salaries
| ₹3 L/yr - ₹6 L/yr |
Junior Manager
39
salaries
| ₹3 L/yr - ₹9.3 L/yr |
Senior Engineer
25
salaries
| ₹3 L/yr - ₹7.8 L/yr |
Senior Supervisor
19
salaries
| ₹2.5 L/yr - ₹5.6 L/yr |
Vedanta Limited
Adani Enterprises
Tata Power
JSW Steel