DOL (Direct-On-Line) and star delta are two different wiring schemes used in electrical engineering for starting induction motors.
DOL wiring directly connects the motor to the power supply for starting, while star delta wiring initially starts the motor in star configuration and then switches to delta configuration for running.
DOL wiring is simpler and cheaper but causes high starting current, while star delta wiring r...
Siemens controllers have different parameters for various applications.
Siemens controllers have different parameters for motion control, temperature control, and process control.
Parameters for motion control include acceleration, deceleration, and maximum velocity.
Parameters for temperature control include setpoint, proportional band, and integral time.
Parameters for process control include setpoint, deadband, and gain...
Fanuc has different parameters for various functions such as motion control, spindle control, and tool management.
Fanuc parameters are used to control various functions such as motion control, spindle control, and tool management.
Parameters can be set to adjust the speed, acceleration, and deceleration of the machine.
Fanuc parameters can also be used to set up alarms and diagnostic messages.
Examples of Fanuc parameters...
PLCs are used in various industries for automation and control purposes.
PLCs are commonly used in manufacturing industries for controlling assembly lines and machines.
They are also used in the automotive industry for controlling robotic arms and conveyor belts.
PLCs are used in the food and beverage industry for controlling mixing and packaging machines.
They are used in the energy sector for controlling power plants and...
VFDs are used to control the speed of AC motors in various applications.
VFDs are commonly used in HVAC systems to control the speed of fans and pumps.
They are also used in industrial applications to control conveyor belts and other machinery.
VFDs can improve energy efficiency and reduce wear and tear on equipment.
They are often used in renewable energy systems to control the speed of wind turbines and solar panels.
VFDs...
posted on 16 Apr 2024
I applied via Referral and was interviewed in Mar 2024. There was 1 interview round.
Aptitude test b.e electronics level
posted on 16 Jul 2024
I applied via Shine and was interviewed in Jan 2024. There were 3 interview rounds.
Daily maintenance procedures for electrical engineers ensure optimal performance and safety of electrical systems.
Inspecting and testing electrical equipment for any signs of wear or damage
Cleaning and lubricating moving parts to prevent friction and overheating
Checking and replacing faulty components such as fuses or circuit breakers
Calibrating sensors and meters to ensure accurate readings
Updating software and firmwa...
DOL (Direct-On-Line) and star delta are two different wiring schemes used in electrical engineering for starting induction motors.
DOL wiring directly connects the motor to the power supply for starting, while star delta wiring initially starts the motor in star configuration and then switches to delta configuration for running.
DOL wiring is simpler and cheaper but causes high starting current, while star delta wiring r...
Siemens controllers have different parameters for various applications.
Siemens controllers have different parameters for motion control, temperature control, and process control.
Parameters for motion control include acceleration, deceleration, and maximum velocity.
Parameters for temperature control include setpoint, proportional band, and integral time.
Parameters for process control include setpoint, deadband, and gain...
Fanuc has different parameters for various functions such as motion control, spindle control, and tool management.
Fanuc parameters are used to control various functions such as motion control, spindle control, and tool management.
Parameters can be set to adjust the speed, acceleration, and deceleration of the machine.
Fanuc parameters can also be used to set up alarms and diagnostic messages.
Examples of Fanuc parameters...
PLCs are used in various industries for automation and control purposes.
PLCs are commonly used in manufacturing industries for controlling assembly lines and machines.
They are also used in the automotive industry for controlling robotic arms and conveyor belts.
PLCs are used in the food and beverage industry for controlling mixing and packaging machines.
They are used in the energy sector for controlling power plants and...
VFDs are used to control the speed of AC motors in various applications.
VFDs are commonly used in HVAC systems to control the speed of fans and pumps.
They are also used in industrial applications to control conveyor belts and other machinery.
VFDs can improve energy efficiency and reduce wear and tear on equipment.
They are often used in renewable energy systems to control the speed of wind turbines and solar panels.
VFDs...
posted on 21 Apr 2024
posted on 21 Sep 2023
I applied via Campus Placement and was interviewed in Mar 2023. There were 3 interview rounds.
The current situation in the electrical engineering field is rapidly evolving with advancements in technology and increasing demand for sustainable energy solutions.
Advancements in renewable energy sources such as solar and wind power are shaping the future of electrical engineering.
The integration of smart grid technology and Internet of Things (IoT) in electrical systems is becoming more prevalent.
Electric vehicles a...
based on 4 reviews
Rating in categories
Assistant Manager
286
salaries
| ₹4.2 L/yr - ₹15 L/yr |
Deputy Manager
241
salaries
| ₹6.4 L/yr - ₹22 L/yr |
Associate Manager
129
salaries
| ₹9.5 L/yr - ₹30 L/yr |
Officer
99
salaries
| ₹3.7 L/yr - ₹8.2 L/yr |
Senior Manager
81
salaries
| ₹16.1 L/yr - ₹40 L/yr |
Tata Group
Reliance Industries
Vedanta Resources
JSW Group