Filter interviews by
Top trending discussions
Designing beams and columns involves determining the size, material, and layout to support the required loads.
Consider the type of structure and the loads it will bear
Calculate the required dimensions and reinforcement based on structural analysis
Select appropriate materials such as steel or concrete
Ensure proper connections and detailing for stability and safety
Limit state of serviceability refers to the condition where a structure is still functioning properly without any excessive deflection or deformation.
Limit state of serviceability ensures that a structure remains usable and safe for occupants.
It involves checking factors like deflection, vibration, cracking, and durability.
For example, a bridge should not deflect excessively under the weight of traffic to maintain serv...
Cement is a binding material used in construction to hold together bricks, stones, and other materials.
Cement is a fine powder made from limestone, clay, and other minerals.
When mixed with water, cement forms a paste that hardens and binds materials together.
Common types of cement include Portland cement, which is used in most construction projects.
Cement is a key ingredient in concrete, mortar, and grout.
Proper curing...
I applied via Walk-in and was interviewed before May 2021. There were 2 interview rounds.
CODAL provisions for concrete refer to the guidelines and regulations set by relevant authorities, while commands of software are the specific instructions or functions within a software program.
CODAL provisions for concrete include specifications for mix design, strength requirements, and durability standards.
Commands of software for site engineers may include functions for structural analysis, quantity takeoff, and p...
The size of a concrete cube is typically 150mm x 150mm x 150mm for standard testing purposes.
Standard size for concrete cube is 150mm x 150mm x 150mm
Used for testing the compressive strength of concrete
Other sizes may be used for specific projects or requirements
posted on 20 Dec 2023
The density of RCC structure typically ranges from 2200 to 2500 kg/m^3.
Density of RCC is influenced by the type and proportion of materials used.
Common density range for RCC is 2200 to 2500 kg/m^3.
Higher density indicates stronger and more durable RCC structure.
I was interviewed in Apr 2023.
I applied via Naukri.com and was interviewed in Nov 2022. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Apr 2024. There was 1 interview round.
Conductors are selected based on factors like material, size, insulation, and current carrying capacity.
Consider the material of the conductor (e.g. copper, aluminum)
Determine the size of the conductor based on the current it will carry
Choose the appropriate insulation for the conductor based on the environment it will be used in
Ensure the conductor has the required current carrying capacity for the application
based on 4 reviews
Rating in categories
Mechanical Engineer
34
salaries
| ₹2 L/yr - ₹5 L/yr |
Electrical Engineer
18
salaries
| ₹2.5 L/yr - ₹5.4 L/yr |
Safety Officer
16
salaries
| ₹2.8 L/yr - ₹4.5 L/yr |
Instrument Engineer
11
salaries
| ₹3 L/yr - ₹5 L/yr |
HR Executive
11
salaries
| ₹2 L/yr - ₹3.6 L/yr |
TCS
Infosys
Wipro
Tech Mahindra