i
Milkbasket
Filter interviews by
Clear (1)
I applied via LinkedIn and was interviewed in Aug 2022. There were 3 interview rounds.
Low fill rate can be dealt with by analyzing the root cause and implementing corrective actions.
Analyze the reasons for low fill rate such as inaccurate forecasting, poor inventory management, or supplier issues
Implement corrective actions such as improving forecasting accuracy, optimizing inventory levels, or finding alternative suppliers
Regularly monitor and measure fill rate to ensure improvements are sustained
Colla...
Top trending discussions
I applied via Company Website and was interviewed before Jun 2020. There were 3 interview rounds.
I applied via Referral and was interviewed in Oct 2019. There was 1 interview round.
I have 5 years of experience managing warehouse operations, including inventory control, shipping/receiving, and staff supervision.
Implemented efficient inventory management system to reduce errors and improve accuracy
Led team in achieving 99% on-time shipping rate by optimizing workflow processes
Trained staff on safety protocols and equipment operation to ensure compliance with OSHA regulations
I applied via Referral and was interviewed before Sep 2020. There was 1 interview round.
Managing vendors involves establishing relationships, setting expectations, monitoring performance, and resolving issues.
Establish clear communication channels with vendors
Set expectations regarding deliverables, timelines, and quality
Regularly monitor vendor performance and provide feedback
Address any issues or concerns promptly and effectively
Negotiate contracts and pricing to ensure value for money
Maintain strong re...
I applied via Recruitment Consultant and was interviewed in Aug 2020. There were 3 interview rounds.
Secondary side current calculations involve determining the current flowing through the transformer and DG.
Calculate the load current on the secondary side of the transformer using the formula I2 = (I1 * V1) / V2
Calculate the current output of the DG using the formula I = P / V
Consider factors such as power factor and efficiency in the calculations
Ensure that the current ratings of the transformer and DG are not exceed
Transformer protections include overcurrent, differential, and earth fault protection.
Overcurrent protection is used to detect and isolate faults in the transformer winding or connected circuits.
Differential protection compares the current entering and leaving the transformer to detect internal faults.
Earth fault protection detects faults between the transformer winding and earth.
Other protections include overvoltage, ...
I applied via Recruitment Consultant and was interviewed in Jun 2020. There was 1 interview round.
I applied via Campus Placement and was interviewed before Feb 2021. There was 1 interview round.
I applied via Recruitment Consultant and was interviewed in Nov 2020. There were 3 interview rounds.
based on 1 interview
Interview experience
based on 9 reviews
Rating in categories
Team Lead
103
salaries
| ₹2 L/yr - ₹5 L/yr |
Supervisor
81
salaries
| ₹1.5 L/yr - ₹3.6 L/yr |
Assistant Manager
60
salaries
| ₹3.8 L/yr - ₹9.5 L/yr |
Deputy Manager
38
salaries
| ₹10.1 L/yr - ₹13 L/yr |
Senior Team Leader
36
salaries
| ₹2.6 L/yr - ₹4.8 L/yr |
BigBasket
Blinkit
Nature's Basket
Spencer's Retail