Filter interviews by
I applied via Walk-in and was interviewed in Aug 2023. There were 2 interview rounds.
Electrical wiring estimation involves calculating the amount of wiring needed for a project.
Determine the total length of wiring required based on the layout of the building or system
Consider the type and gauge of wires needed for different components
Factor in any special requirements such as conduit or cable trays
Estimate the cost of materials and labor for the wiring installation
Top trending discussions
posted on 2 Jul 2022
I applied via Walk-in and was interviewed before Jul 2021. There were 2 interview rounds.
Arithmetic and logical reasoning
I applied via Naukri.com and was interviewed before Aug 2020. There were 3 interview rounds.
posted on 6 Jan 2024
I applied via Approached by Company and was interviewed in Jul 2023. There were 4 interview rounds.
30min test from core subject
Usual GD on a relevant topic, everyone gets the opportunity to talk. Make relevant points and stick on to your opinion.
posted on 14 Aug 2024
I applied via Campus Placement and was interviewed in Jul 2024. There were 3 interview rounds.
About power system control system
Present trends and tgey willgive 10 min to think and note down
posted on 26 Aug 2023
I applied via Recruitment Consulltant and was interviewed in Jul 2023. There were 2 interview rounds.
Automatic Transfer Switches are devices used to automatically switch power sources in case of a power outage.
Types of automatic transfer switches include open transition, closed transition, and delayed transition.
Examples of automatic transfer switch manufacturers include Generac, Eaton, and Schneider Electric.
Automatic transfer switches are commonly used in backup power systems for critical facilities like hospitals,
posted on 2 Jun 2024
Circuit breakers are electrical switches designed to protect electrical circuits from damage caused by overload or short circuit.
Circuit breakers automatically trip when they detect an overload or short circuit in the electrical system.
They interrupt the flow of electricity to prevent damage to the circuit or electrical devices.
Circuit breakers can be reset manually after tripping to restore power to the circuit.
There ...
I was interviewed before Mar 2024.
Transformer differential protection is a method to protect transformers from internal faults. CT sizing is determined based on the transformer's primary current rating.
Transformer differential protection compares the currents entering and leaving the transformer to detect internal faults.
Current transformers (CTs) are sized based on the transformer's primary current rating and the desired accuracy of the protection sch...
Unbalanced protection in electrical systems is a type of protection that detects and responds to imbalances in current or voltage levels.
Unbalanced protection is used to detect faults such as phase-to-phase or phase-to-ground faults in electrical systems.
It helps prevent damage to equipment and ensures the safety of personnel by quickly isolating the faulty section of the system.
Examples of unbalanced protection device...
Yes, the use of a smartphone camera flasher is permitted while assessing old switchgears for modernization.
Using a smartphone camera flasher can help illuminate dark areas and improve visibility while assessing old switchgears.
It can assist in capturing clear and detailed images for documentation and analysis.
Ensure that the flash does not interfere with any sensitive equipment or cause any safety hazards.
Consider usin...
I am currently earning X amount and my salary expectations are Y amount.
Mention your current CTC (Cost to Company)
Clearly state your salary expectations
Consider factors like experience, industry standards, and job responsibilities when stating salary expectations
Seeking new challenges and opportunities for growth.
Desire for new challenges and learning opportunities
Limited growth potential in current role
Seeking a more innovative and dynamic work environment
During a site visit for assessing existing switchgear for retrofitting circuit breakers, inputs collected include equipment specifications, condition, age, and load requirements.
Collect equipment specifications such as voltage rating, current rating, and interrupting capacity.
Assess the condition of the existing switchgear to determine if it can accommodate the new circuit breakers.
Consider the age of the switchgear to...
Seeking new challenges and opportunities for growth.
Desire for new challenges and learning opportunities
Limited growth potential in current role
Seeking a more innovative and dynamic work environment
Seeking new challenges and opportunities for growth in a field that aligns more closely with my interests and skills.
Desire for new challenges and opportunities
Interest in pursuing a career that aligns better with skills and passions
Seeking professional growth and development
Exploring a field with more potential for advancement
Wanting to broaden knowledge and experience in a different industry
My current CTC is $80,000 per year, and my expected CTC is $90,000 per year.
Current CTC: $80,000 per year
Expected CTC: $90,000 per year
Reasons for expecting increase in CTC (if applicable)
Yes, I am open to relocation for the right opportunity.
I am willing to relocate for the right job opportunity that aligns with my career goals.
I am open to exploring new locations and experiencing different cultures.
I understand that relocation may be necessary for career advancement and growth.
posted on 8 Jan 2015
Discussion on soil mechanics starting from modulus of elasticity to liquifaction
Modulus of elasticity is a measure of soil stiffness
Soil strength is important in determining its ability to withstand loads
Liquifaction occurs when soil loses strength and behaves like a liquid
Factors affecting soil strength include soil type, moisture content, and stress history
Liquifaction can lead to soil failure and damage to structure
posted on 15 May 2021
I applied via Company Website and was interviewed in Nov 2020. There was 1 interview round.
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Design Engineer
96
salaries
| ₹0 L/yr - ₹0 L/yr |
CAD Engg
80
salaries
| ₹0 L/yr - ₹0 L/yr |
System Engineer
55
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
35
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Design Engineer
33
salaries
| ₹0 L/yr - ₹0 L/yr |
Siemens Energy
BHEL
Thermax Limited
Kirloskar Brothers