I applied via Campus Placement and was interviewed in Jul 2024. There were 3 interview rounds.
About power system control system
Present trends and tgey willgive 10 min to think and note down
Circuit breakers are electrical switches designed to protect electrical circuits from damage caused by overload or short circuit.
Circuit breakers automatically trip when they detect an overload or short circuit in the electrical system.
They interrupt the flow of electricity to prevent damage to the circuit or electrical devices.
Circuit breakers can be reset manually after tripping to restore power to the circuit.
There ...
I applied via Recruitment Consulltant and was interviewed in Jul 2023. There were 2 interview rounds.
Automatic Transfer Switches are devices used to automatically switch power sources in case of a power outage.
Types of automatic transfer switches include open transition, closed transition, and delayed transition.
Examples of automatic transfer switch manufacturers include Generac, Eaton, and Schneider Electric.
Automatic transfer switches are commonly used in backup power systems for critical facilities like hospitals,
I applied via Approached by Company and was interviewed in Jul 2023. There were 4 interview rounds.
30min test from core subject
Usual GD on a relevant topic, everyone gets the opportunity to talk. Make relevant points and stick on to your opinion.
Schneider Electric interview questions for designations
Top trending discussions
posted on 19 Feb 2024
I applied via Naukri.com and was interviewed in Aug 2023. There was 1 interview round.
I applied via Approached by Company and was interviewed in Nov 2022. There were 2 interview rounds.
PLC and card selection depends on the application requirements and budget.
Identify the required inputs and outputs
Consider the communication protocols needed
Evaluate the processing power and memory requirements
Determine the budget and cost of ownership
Research and compare different brands and models
Consider the availability of technical support and spare parts
Ensure compatibility with existing systems
Consider the envir
I applied via Recruitment Consulltant and was interviewed before Aug 2022. There were 4 interview rounds.
posted on 18 Jul 2024
PLC stands for Programmable Logic Controller, used in industrial automation to control machinery and processes.
PLC is a digital computer used for automation of electromechanical processes.
It uses a programmable memory to store instructions and specific functions.
PLCs are commonly used in manufacturing plants, assembly lines, and robotic devices.
They can be programmed using ladder logic, function block diagrams, or stru...
Industrial automation involves the use of control systems such as robots and computers to handle different processes and machinery in an industrial setting.
Industrial automation helps improve efficiency and productivity by reducing human intervention in repetitive tasks.
It involves the use of sensors, actuators, and controllers to monitor and control various processes.
Examples of industrial automation include automated...
posted on 22 Feb 2024
Star delta controlling is a method used to reduce the starting current of induction motors.
Star delta controlling involves initially connecting the motor windings in a star configuration for starting, then switching to a delta configuration for running.
It is commonly used for large induction motors to reduce the starting current and torque.
The transition from star to delta configuration is typically controlled by a mot...
In star delta connection, typically two contactors are used.
In star delta connection, one contactor is used for star connection and another contactor is used for delta connection.
The star contactor is typically rated for the current of one winding, while the delta contactor is rated for the full motor current.
Using two contactors helps in reducing the starting current and torque in the motor.
For example, a 3-phase moto...
Single line diagram for DOL is a simple representation of Direct-On-Line motor starter circuit.
DOL starter consists of a contactor, overload relay, and start/stop push buttons.
The single line diagram shows the connections between these components.
The power supply is connected to the contactor, which is then connected to the motor.
The overload relay is connected in series with the motor to protect it from overloading.
St...
Interview experience
based on 11 reviews
Rating in categories
Deputy Manager
1.3k
salaries
| ₹5 L/yr - ₹12 L/yr |
Senior Manager
668
salaries
| ₹8.5 L/yr - ₹28 L/yr |
Manager
644
salaries
| ₹5.8 L/yr - ₹22 L/yr |
Assistant Manager
322
salaries
| ₹3.8 L/yr - ₹11 L/yr |
Deputy General Manager
308
salaries
| ₹18 L/yr - ₹42.2 L/yr |
Siemens
ABB
Honeywell Automation
Emerson Electric Co.