An air circuit breaker is an electrical device that provides protection against overcurrents by using air as the medium to extinguish the arc.
Air circuit breakers work on the principle of thermal and magnetic tripping.
When an overcurrent flows through the circuit, the bimetallic strip in the breaker heats up and bends, causing the contacts to open.
The arc generated during the opening of contacts is extinguished by the ...
Losses in transformer refer to the energy lost in the form of heat during the process of transforming voltage.
There are two types of losses in transformers: copper losses and iron losses.
Copper losses occur due to the resistance of the wire used in the transformer's windings.
Iron losses occur due to the magnetic properties of the transformer's core material.
Copper losses can be reduced by using thicker wire or increasi...
UPS system ensures uninterrupted power supply during power outages.
UPS stands for Uninterruptible Power Supply.
It provides backup power to critical equipment during power outages.
UPS systems can be of different types such as online, offline, and line-interactive.
UPS systems are commonly used in data centers, hospitals, and other critical facilities.
UPS provides backup power during power outages while stabilizer maintains a constant voltage output.
UPS stands for Uninterruptible Power Supply and provides backup power during power outages.
Stabilizer maintains a constant voltage output and protects electrical equipment from voltage fluctuations.
UPS is used for critical equipment like servers, medical equipment, etc. while stabilizer is used for household appliances l
Preventive maintenance in electrical systems involves regular inspections, testing, and servicing to prevent equipment failures and ensure optimal performance.
Regularly inspect electrical equipment for signs of wear, damage, or overheating.
Perform routine testing and calibration of electrical systems to identify potential issues before they cause failures.
Clean and lubricate electrical components to prevent dust buildu...
Top trending discussions
posted on 7 Oct 2021
I applied via Naukri.com and was interviewed in Sep 2021. There were 3 interview rounds.
posted on 31 Jan 2025
Delta motor wiring connection circuit diagram involves connecting three phases in a triangular configuration.
Connect the three motor windings in a triangular configuration
Label the three phases as A, B, and C
Connect the end of one winding to the start of the next winding
Ensure proper insulation and secure connections
Use appropriate wire sizes and color codes for easy identification
Sensors are devices that detect changes in physical properties and convert them into electrical signals. They come in various types and have specific working conditions.
Types of sensors include temperature sensors, pressure sensors, proximity sensors, motion sensors, etc.
Sensors work by detecting changes in physical properties such as temperature, pressure, light, etc., and converting them into electrical signals.
Worki...
posted on 24 Feb 2022
My name is vijay vignesh j
I am studied diploma electrical electronics engineering kumbakonam
I am coming from Valangaiman
Now iam staying in chennai
I am working sri chakra engginers in service and electrical Maintanance
My work experience 5 years
My father is a former
posted on 23 Apr 2023
I applied via Naukri.com and was interviewed in Sep 2022. There were 4 interview rounds.
posted on 17 Feb 2025
CNC stands for Computer Numerical Control, which is a system that controls the operation of machine tools through programmed commands.
CNC machines are used in various industries such as manufacturing, aerospace, automotive, and healthcare.
Types of CNC machines include CNC milling machines, CNC lathes, CNC routers, and CNC plasma cutters.
CNC machines can be classified based on the number of axes they operate on, such as...
I applied via Referral and was interviewed before Jul 2020. There was 1 interview round.
I applied via Referral and was interviewed before Dec 2020. There were 3 interview rounds.
posted on 14 Dec 2023
I applied via Referral and was interviewed in Jan 2024. There were 2 interview rounds.
Regarding previous job working details
Previous site infrastructure included data centers, networking equipment, servers, and storage systems.
Data centers were located in multiple regions for redundancy.
Networking equipment included routers, switches, and firewalls.
Servers were a mix of physical and virtual machines.
Storage systems used SAN and NAS technologies.
Backup and disaster recovery plans were in place.
Monitoring tools were used to track performance
Multiple scenarios of UPS DG CHILLER FAILURES
based on 1 review
Rating in categories
Technical Supervisor
52
salaries
| ₹1.8 L/yr - ₹4 L/yr |
Electrician
33
salaries
| ₹1.4 L/yr - ₹2.5 L/yr |
Electrical Technician
22
salaries
| ₹1.5 L/yr - ₹2.5 L/yr |
Technician
19
salaries
| ₹1.3 L/yr - ₹3 L/yr |
Shift Engineer
17
salaries
| ₹2.5 L/yr - ₹3.6 L/yr |
ISS Facility Services
Compass Group Support Services
BVG India
Leadec India