Filter interviews by
I applied via Company Website and was interviewed in Jan 2024. There was 1 interview round.
Column Diameter refers to the width of a column and is typically measured in units such as inches or millimeters.
Column Diameter is the measurement of the width of a column.
It is usually expressed in units such as inches or millimeters.
Column Diameter is an important parameter in various industries, including construction and manufacturing.
For example, in the construction of a building, the column diameter determines t...
Linear gradient of elution is a technique used in chromatography to separate components based on their affinity to the mobile and stationary phases.
Linear gradient of elution involves changing the composition of the mobile phase over time.
It is used to separate components with different affinities to the stationary phase.
The gradient can be achieved by gradually increasing or decreasing the concentration of a solvent o...
Planned deviation and change control are both related to managing changes in a project, but they differ in their nature and purpose.
Planned deviation refers to a deliberate and pre-approved deviation from the original plan or specifications.
Change control, on the other hand, is a systematic process for evaluating, approving, and implementing changes to the project.
Planned deviation is typically used when there is a nee...
The asymmetric factor of a column refers to the uneven distribution of load or stress along its length.
The asymmetric factor can affect the structural integrity of the column.
It is important to consider the asymmetric factor when designing and constructing columns.
Examples of factors that can contribute to asymmetry include uneven loading, eccentricity, and structural irregularities.
The asymmetric factor can be quantif...
Linear flow velocity of a column refers to the speed at which a fluid moves through the column. Flow rate is the volume of fluid passing through a given point per unit time.
Linear flow velocity is calculated by dividing the flow rate by the cross-sectional area of the column.
Flow rate can be measured in various units such as liters per minute, gallons per hour, or cubic meters per second.
Linear flow velocity is importa...
I applied via LinkedIn and was interviewed in Feb 2024. There was 1 interview round.
I applied via LinkedIn
Questions were asked best on my resume and past work experience
Laurus Bio interview questions for popular designations
I applied via Referral and was interviewed in Feb 2021. There was 1 interview round.
I applied via Referral and was interviewed in May 2021. There were 3 interview rounds.
I was interviewed before Feb 2021.
I am a QC Microbiologist with experience in performing microbiological testing and analysis.
I have a Bachelor's degree in Microbiology.
I have worked in a pharmaceutical company for 3 years, conducting microbiological testing on raw materials, finished products, and environmental samples.
I am skilled in using various microbiological techniques such as microbial culture, identification, and enumeration.
I have experience ...
Yes, MLT stands for Microbial Limit Testing. Dilution is done by adding a known volume of a sample to a known volume of diluent.
MLT stands for Microbial Limit Testing.
Dilution is done by adding a known volume of a sample to a known volume of diluent.
The purpose of dilution is to reduce the concentration of microorganisms in a sample to a level that can be accurately counted or tested.
Serial dilutions are commonly used ...
Top trending discussions
posted on 6 Dec 2024
posted on 6 Nov 2024
I applied via LinkedIn and was interviewed in Oct 2024. There were 2 interview rounds.
Interview experience
based on 41 reviews
Rating in categories
Executive
32
salaries
| ₹3 L/yr - ₹6.6 L/yr |
Junior Executive
30
salaries
| ₹3 L/yr - ₹5 L/yr |
Senior Executive
20
salaries
| ₹5 L/yr - ₹8.1 L/yr |
Senior Research Associate
14
salaries
| ₹4 L/yr - ₹7.8 L/yr |
Manager
13
salaries
| ₹10.1 L/yr - ₹18 L/yr |
Biocon Limited
Syngene International
DRJ & CO
DIVI'S Laboratories