The scope of work in a chiller plant includes installation, maintenance, troubleshooting, and optimization of chiller systems.
Installation of chiller units and associated equipment
Regular maintenance to ensure optimal performance
Troubleshooting issues such as leaks, malfunctions, or inefficiencies
Optimizing chiller plant operations for energy efficiency
Ensuring compliance with safety and environmental regulations
Monito...
Access control system, Fire alarm system, HVAC, VESDA are all essential components of building infrastructure.
Access control system: regulates who can enter or exit a building or specific areas within a building.
Fire alarm system: detects and alerts occupants of a building in case of fire or smoke.
HVAC (Heating, Ventilation, and Air Conditioning): controls the temperature, humidity, and air quality within a building.
VE...
posted on 13 Oct 2023
TCS system stands for Turbine Control System, which is used in power plants to control and monitor the operation of turbines.
TCS system is essential for ensuring the safe and efficient operation of turbines in power plants.
It helps in controlling the speed, temperature, and other parameters of the turbine.
TCS system also includes safety features to protect the turbine from damage.
Examples of TCS systems include Woodwar
TCS (Temperature Control System) can be controlled using various methods such as PID controllers, PLCs, and SCADA systems.
Use PID controllers to regulate temperature by adjusting the output based on the difference between the setpoint and actual temperature.
Program PLCs to monitor and control temperature by receiving input from sensors and activating outputs to adjust heating or cooling devices.
Implement SCADA systems ...
Scalance type selection is based on factors like network size, speed requirements, and redundancy needs.
Consider the size of the network to determine the number of ports needed
Evaluate the speed requirements to choose between Fast Ethernet or Gigabit Ethernet
Assess the redundancy needs to decide on features like ring redundancy or port redundancy
Examples: Scalance X-200 for small networks, Scalance X-400 for larger net
Load calculation in Engineering Design involves determining the amount of force or weight that a structure or component will need to support.
Load calculation considers factors such as dead load, live load, wind load, seismic load, and temperature variations.
Dead load refers to the weight of the structure itself and any permanent fixtures.
Live load includes the weight of people, furniture, and other temporary items.
Wind...
The challenge in designing and site activity is ensuring that the design is practical and can be successfully implemented on site.
Ensuring that the design meets all technical requirements and specifications
Coordinating with various teams involved in the project to ensure smooth execution
Managing unexpected challenges that may arise during the erection and commissioning process
Adapting the design if necessary to overcom...
Current is the flow of electric charge in a circuit.
Current is measured in Amperes (A)
It is the rate of flow of electric charge
Current flows from high voltage to low voltage
In a series circuit, the current is the same at all points
In a parallel circuit, the total current is the sum of the currents through each branch
Soft starters are preferred over star-delta starters for motor start and run due to their ability to reduce inrush current and provide smoother acceleration.
Soft starters provide a gradual increase in voltage to the motor, reducing inrush current and mechanical stress on the motor.
Star-delta starters provide a sudden increase in voltage, resulting in high inrush current and mechanical stress on the motor.
Soft starters ...
Encoders used in industrial include absolute, incremental, linear, rotary, magnetic, and optical encoders.
Absolute encoders provide a unique code for each position
Incremental encoders provide a pulse output for each position change
Linear encoders measure linear motion
Rotary encoders measure rotational motion
Magnetic encoders use a magnetic field to detect position
Optical encoders use light to detect position
VFD parameters are settings that control the operation of a variable frequency drive.
VFD parameters include frequency, voltage, current, acceleration/deceleration time, and motor overload protection
Frequency parameter determines the speed of the motor
Voltage parameter determines the amount of voltage supplied to the motor
Current parameter determines the amount of current supplied to the motor
Acceleration/deceleration t...
I applied via Referral and was interviewed in Jun 2022. There were 2 interview rounds.
based on 2 reviews
Rating in categories
Assistant Manager
1.2k
salaries
| ₹4.5 L/yr - ₹12 L/yr |
Senior Executive
1.1k
salaries
| ₹3 L/yr - ₹9.5 L/yr |
Deputy Manager
631
salaries
| ₹6.8 L/yr - ₹12.6 L/yr |
Manager
348
salaries
| ₹6.9 L/yr - ₹18 L/yr |
Applications Engineer
344
salaries
| ₹3.5 L/yr - ₹11 L/yr |
Siemens
Honeywell Automation
Schneider Electric
ABB