Filter interviews by
Home load of a power plant is received through a distribution network.
Home load is received from the power plant through a distribution network.
The power plant generates electricity and sends it to a substation.
The substation then distributes the electricity to homes through power lines.
The distribution network ensures that the electricity reaches each home efficiently.
Examples of distribution networks include overhead
A blackout condition refers to a complete loss of electrical power in a specific area or across a larger region.
Blackouts can be caused by various factors such as equipment failure, severe weather conditions, or intentional power cuts.
During a blackout, all electrical devices and systems dependent on electricity cease to function.
Blackouts can last for a few seconds, minutes, hours, or even days depending on the cause ...
Top trending discussions
The chance of survival depends on various factors such as insulation, grounding, and the strength of the electrical surge.
The chance of survival depends on the insulation of the car, as it acts as a barrier against electrical current.
If the car is properly grounded, it can help dissipate the electrical surge and reduce the risk of injury.
The strength of the electrical surge also plays a crucial role in determining the ...
I applied via Referral and was interviewed before Aug 2021. There was 1 interview round.
DC motors use direct current to generate rotational motion, while AC motors use alternating current.
DC motors have a commutator and brushes to switch the current direction
AC motors have a stator and rotor to create a rotating magnetic field
DC motors are commonly used in household appliances and electric vehicles
AC motors are commonly used in industrial machinery and HVAC systems
I applied via Company Website and was interviewed in Feb 2022. There was 1 interview round.
I applied via Naukri.com and was interviewed in Nov 2022. There were 2 interview rounds.
A thermocouple is a device that measures temperature by detecting the voltage difference between two different metals.
Consists of two different metal wires joined at one end
Produces a voltage that varies with temperature
Used in temperature measurement and control systems
Commonly used in industrial applications such as furnaces and boilers
The ohmic value of PT-100 is 100 ohms at 0°C.
PT-100 is a type of platinum resistance thermometer.
It has a resistance of 100 ohms at 0°C.
The resistance increases with temperature at a rate of 0.385 ohms/°C.
PT-100 is commonly used in industrial temperature measurement applications.
Calibration 3.0 and 5.0 refer to the accuracy level of a measuring instrument.
Calibration 3.0 means the instrument has an accuracy level of 0.3% of the full scale reading.
Calibration 5.0 means the instrument has an accuracy level of 0.5% of the full scale reading.
The higher the calibration number, the more accurate the instrument is.
Calibration is the process of adjusting an instrument to ensure its accuracy.
Calibratio...
posted on 13 Jun 2024
I applied via Recruitment Consulltant and was interviewed in Dec 2023. There was 1 interview round.
Improving power factor helps in reducing energy losses, increasing system efficiency, and reducing electricity costs.
Improving power factor reduces the amount of reactive power flowing in the system, which in turn reduces energy losses.
Higher power factor means more efficient use of electricity and less strain on the electrical system.
Improving power factor can lead to reduced electricity costs for consumers and utilit...
Buccholz relay is a protective device used in oil-filled transformers to detect faults such as internal arcing or overheating.
Buccholz relay is installed in the oil pipe connecting the transformer tank and conservator tank.
It works based on the principle that gas is generated when a fault occurs in the transformer, causing oil level to drop and gas to accumulate in the relay.
The relay consists of two float switches - o...
DP in Siemens communication stands for Distributed Peripherals.
DP is a communication protocol used by Siemens for connecting distributed peripherals to a central control system.
It allows for real-time data exchange between the peripherals and the control system.
DP is commonly used in industrial automation applications.
Examples of DP communication modules include DP/DP couplers and DP slaves.
To communicate S7 PLC and ABB drive using Profibus, you need to configure the Profibus network, set up the communication parameters, and establish the communication link.
Configure the Profibus network by setting the correct baud rate, address, and other network parameters.
Set up the communication parameters on both the S7 PLC and ABB drive to ensure they are compatible with each other.
Establish the communication link b...
posted on 11 Jun 2023
I applied via Referral and was interviewed before Jun 2022. There were 3 interview rounds.
posted on 15 Jan 2023
posted on 30 Jan 2023
I applied via Approached by Company and was interviewed in Jul 2022. There were 3 interview rounds.
posted on 3 Jun 2022
I applied via Campus Placement and was interviewed in May 2022. There were 3 interview rounds.
Reasoning and aptitude with technical
The duration of Jindal Steel and Power Electrical Engineer interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 1 interview
Interview experience
based on 19 reviews
Rating in categories
Assistant Manager
2.3k
salaries
| ₹4.2 L/yr - ₹13.6 L/yr |
Junior Engineer
1k
salaries
| ₹1.8 L/yr - ₹5.6 L/yr |
Deputy Manager
985
salaries
| ₹5.7 L/yr - ₹18.4 L/yr |
Assistant Engineer
834
salaries
| ₹2.4 L/yr - ₹8.5 L/yr |
Manager
623
salaries
| ₹9 L/yr - ₹24.2 L/yr |
Tata Steel
JSW Steel
ArcelorMittal Nippon Steel
Jindal Stainless