i
Jindal Saw
Filter interviews by
I applied via Company Website and was interviewed in Sep 2021. There was 1 interview round.
I applied via Walk-in and was interviewed before Nov 2021. There were 2 interview rounds.
I have 5 years of experience as a Mechanical Maintenance Technician.
I have worked in the field for 5 years.
I have experience in troubleshooting and repairing mechanical equipment.
I have knowledge of preventive maintenance procedures.
I have worked with various tools and equipment used in mechanical maintenance.
I have successfully completed projects that involved maintaining and servicing machinery.
I have experience in r...
posted on 13 Jan 2024
The first material production in a steel plant is iron ore.
Iron ore is the primary raw material used in steel production.
It is mined from the earth and then processed to remove impurities.
The processed iron ore is then used in blast furnaces to produce molten iron, which is further refined to create steel.
Other materials such as coal and limestone are also used in the steelmaking process.
posted on 29 Oct 2023
I applied via Walk-in and was interviewed in Sep 2023. There was 1 interview round.
I applied via Company Website and was interviewed in Jul 2018. There were 5 interview rounds.
Implemented a new customer feedback system resulting in increased customer satisfaction and retention rates.
Identified the need for a more efficient feedback system
Researched and implemented a new software to collect and analyze customer feedback
Analyzed the data to identify trends and areas for improvement
Implemented changes based on feedback leading to improved customer satisfaction and retention rates
I have a strong passion for leadership and a proven track record of motivating teams to achieve success.
Proven track record of successfully leading teams in previous roles
Passionate about developing and mentoring team members
Strong communication and interpersonal skills
Ability to problem-solve and make quick decisions under pressure
Composite error and ratio error are two types of errors in current transformers.
Composite error is the combination of ratio error and phase angle error in a current transformer.
Ratio error is the difference between the actual turns ratio and the specified turns ratio of a current transformer.
Phase angle error is the angular difference between the primary and secondary currents of a current transformer.
Composite error a...
An AC drive circuit diagram controls the speed of an AC motor by varying the frequency and voltage of the power supplied to it.
An AC drive consists of a rectifier, DC link, inverter, and control circuitry.
The rectifier converts AC power to DC power, which is stored in the DC link.
The inverter converts the DC power back to AC power with variable frequency and voltage.
The control circuitry adjusts the frequency and volta...
A single line diagram of a distribution system is required with proper specifications.
The diagram should show the flow of power from the source to the load
It should include all components such as transformers, switchgear, and cables
The specifications should include voltage levels, power ratings, and protection devices
The diagram should follow standard symbols and conventions
Example: A 11 kV distribution system with a 5
Dewpoint test is done in transformer to check the moisture content in the insulation oil.
Moisture in insulation oil can cause breakdown of transformer insulation
Dewpoint test helps to determine the moisture content in the oil
It is a preventive maintenance measure to avoid transformer failure
The test involves cooling a mirror until dew forms on it, and measuring the temperature at which dew forms
Power transformers are used in transmission systems to step up or down voltage, while distribution transformers are used in distribution systems to step down voltage.
Power transformers are used in high voltage transmission systems to step up or down voltage for long distance transmission.
Distribution transformers are used in low voltage distribution systems to step down voltage for local distribution.
Power transformers...
Buchholz relay is used to protect transformers from faults by detecting gas and oil flow abnormalities.
Buchholz relay is installed in the pipe connecting the transformer tank and conservator tank.
It operates based on the principle that faults in the transformer generate gases and cause oil flow disturbances.
When gas or oil flow abnormalities occur, the relay trips and sends a signal to the control panel to isolate the ...
I applied via Recruitment Consultant and was interviewed in May 2019. There were 3 interview rounds.
I applied via Referral and was interviewed before Aug 2021. There was 1 interview round.
DC motors use direct current to generate rotational motion, while AC motors use alternating current.
DC motors have a commutator and brushes to switch the current direction
AC motors have a stator and rotor to create a rotating magnetic field
DC motors are commonly used in household appliances and electric vehicles
AC motors are commonly used in industrial machinery and HVAC systems
I applied via Campus Placement and was interviewed before Jul 2021. There were 4 interview rounds.
Topic was WHICH COMES FIRST? SAFETY, PRODUCTION OR QUALITY?
based on 1 interview
Interview experience
based on 2 reviews
Rating in categories
Assistant Manager
393
salaries
| ₹4.4 L/yr - ₹13.9 L/yr |
Senior Executive
310
salaries
| ₹3 L/yr - ₹8.8 L/yr |
Deputy Manager
250
salaries
| ₹6.5 L/yr - ₹17 L/yr |
Senior Engineer
190
salaries
| ₹3 L/yr - ₹9 L/yr |
Manager
132
salaries
| ₹8.2 L/yr - ₹19.6 L/yr |
Tata Steel
JSW Steel
Jindal Steel and Power
ArcelorMittal Nippon Steel