Q1. Where is tap changer in a transfermer located and why?If the voltage output in secondary decreases what will be location of tap changer?
Tap changer in a transformer is located on the high voltage winding side to regulate the voltage output.
Tap changer is typically located on the high voltage winding side of a transformer.
It is used to adjust the turns ratio and regulate the voltage output.
If the voltage output in the secondary decreases, the tap changer will be moved to a higher tap position to increase the voltage.
Q2. What is the process of hipot in busbar, breakers, cables and trafo?
Hipot testing is a process used to verify the insulation integrity of busbars, breakers, cables, and transformers.
Hipot testing involves applying a high voltage to the component being tested.
The purpose is to check for any insulation breakdown or leakage current.
For busbars and cables, the test is typically performed between the conductor and the ground.
For breakers and transformers, the test is performed between different terminals or windings.
The test voltage is usually hig...read more
Q3. What if battery polarity is inverse with respect to battery charger?
If battery polarity is inverse with respect to battery charger, it can lead to damage or malfunction.
Inverse polarity can cause short circuits or overheating.
It can damage the battery, charger, or both.
Reverse polarity protection circuits can prevent damage.
Always double-check the polarity before connecting the battery to the charger.
Q4. How many times hipot test can be done on a cable?
The hipot test can be done on a cable multiple times depending on the specific requirements and standards.
The number of times a hipot test can be done on a cable depends on the cable's specifications and the testing requirements.
Generally, a hipot test is performed once during the manufacturing process to ensure the cable's insulation integrity.
However, additional hipot tests may be conducted during the cable's lifespan for maintenance or troubleshooting purposes.
The frequenc...read more
Q5. What type of quality documents you have handled?
I have handled various quality documents such as quality control plans, inspection reports, and non-conformance reports.
Quality control plans
Inspection reports
Non-conformance reports
Q6. What are the tests done on power transformer?
Tests done on power transformers include insulation resistance, turns ratio, winding resistance, and dielectric tests.
Insulation resistance test checks the insulation quality of the transformer.
Turns ratio test measures the ratio of primary to secondary turns.
Winding resistance test determines the resistance of transformer windings.
Dielectric tests assess the dielectric strength and insulation properties of the transformer.
Other tests may include temperature rise, short-circu...read more
Q7. What is the difference between IR, WR and CR?
IR, WR, and CR are abbreviations used in different contexts. IR stands for Infrared, WR stands for Weather Resistant, and CR stands for Compression Ratio.
IR refers to Infrared, which is a type of electromagnetic radiation with longer wavelengths than visible light.
WR is used to indicate that a product or material is designed to withstand various weather conditions.
CR is a term commonly used in engineering and physics to describe the ratio of the volume of a compressed substan...read more
Q8. How many types of earthing are there?
There are several types of earthing used in electrical systems.
The most common types of earthing are:
- TN-S system: Separate neutral and protective earth conductors
- TN-C system: Combined neutral and protective earth conductors
- TN-C-S system: Combination of TN-S and TN-C systems
- TT system: Separate earth electrode for each electrical installation
- IT system: No direct connection between earth and neutral
Each type of earthing has its own advantages and is used in different s...read more
Q9. What are the tests performed on PT?
Tests performed on PT include prothrombin time, international normalized ratio, and clotting factor assays.
Prothrombin time (PT) measures the time it takes for blood to clot.
International normalized ratio (INR) is a standardized measurement of PT used to monitor the effectiveness of anticoagulant therapy.
Clotting factor assays are performed to identify deficiencies or abnormalities in specific clotting factors.
Other tests like activated partial thromboplastin time (aPTT) and ...read more
Q10. What is the process for testing soil compaction?
Soil compaction testing involves using specialized equipment to measure the density and moisture content of soil.
Use a soil compaction tester to measure the density of the soil.
Take samples at different depths to ensure accurate results.
Calculate the compaction percentage by comparing the field density to the maximum density.
Check the moisture content of the soil to ensure it is within the acceptable range.
Repeat the testing process in multiple locations to ensure consistency...read more
Q11. What are the criteria for cube testing?
Criteria for cube testing include sample preparation, curing, testing age, and acceptance criteria.
Sample preparation involves properly filling the cube mold with concrete and compacting it.
Curing the cubes in a controlled environment for a specified period of time is crucial for accurate results.
Testing age refers to the duration after which the cubes are tested, typically 7 or 28 days.
Acceptance criteria vary based on the strength of concrete required for the project.
Q12. List count of vernier caliper and Gd&t profile projector and some other
Count of tools in a Junior Engineer interview
Vernier caliper - 1
GD&T profile projector - 1
Other tools - not specified
Q13. What is deferent between SR and Normalised
SR and Normalised are two different terms used in different contexts.
SR stands for Systematic Review, which is a type of research study that involves a comprehensive and thorough review of existing literature on a particular topic.
Normalization is a process of organizing data in a database to reduce redundancy and improve data integrity.
SR is used in the context of research studies, while normalization is used in the context of database management.
SR involves a critical appra...read more