Filter interviews by
I applied via Walk-in and was interviewed before Jun 2023. There were 2 interview rounds.
Current refers to the flow of electric charge in a circuit or the present time.
Current is measured in Amperes (A)
There are two types of current - direct current (DC) and alternating current (AC)
In a circuit, current flows from the positive terminal of the voltage source to the negative terminal
Current can be calculated using Ohm's Law: I = V/R, where I is current, V is voltage, and R is resistance
Transformers are rated in KVA because it represents the apparent power capacity of the transformer, taking into account both the voltage and current.
KVA takes into account both the voltage and current, providing a more accurate representation of the transformer's capacity
KVA is a unit of apparent power, which is the combination of real power (KW) and reactive power (KVAR)
KVA rating helps in determining the maximum load...
I applied via Referral and was interviewed before Apr 2023. There was 1 interview round.
posted on 10 Oct 2024
I applied via Monster and was interviewed before Oct 2020. There were 3 interview rounds.
Yes, electrical load calculation is the process of determining the amount of power that a building or electrical system requires.
Electrical load calculation involves considering the power requirements of various electrical devices and appliances in a building or system.
Factors such as voltage, current, and power factor are taken into account during the calculation.
Load calculation helps in determining the appropriate s...
Developed a new power distribution system for a large manufacturing plant, resulting in a 20% increase in efficiency.
Designed and implemented a new power distribution system for a large manufacturing plant
Collaborated with a team of engineers and technicians to ensure successful installation and operation
Resulted in a 20% increase in efficiency and significant cost savings for the company
I applied via Company Website and was interviewed before Apr 2020. There were 3 interview rounds.
Layout of combined cycle power plant with different structures and components.
Combined cycle power plant consists of gas turbine, heat recovery steam generator, and steam turbine.
Gas turbine generates electricity by burning natural gas or oil.
Heat recovery steam generator recovers waste heat from gas turbine exhaust and generates steam.
Steam turbine generates additional electricity using the steam produced by heat reco...
Designing machine foundation for gas turbine involves several factors and types of foundations.
Factors to consider include soil type, turbine size and weight, seismic activity, and environmental conditions.
Types of foundations include block, pile, and raft foundations.
Block foundations are suitable for smaller turbines on stable soil.
Pile foundations are used for larger turbines or unstable soil.
Raft foundations are us...
Ductile detailing for beam, column, and foundation involves following IS codes and ensuring proper reinforcement placement.
For beams, IS 13920 is followed and reinforcement is placed at the bottom of the beam.
For columns, IS 13920 and IS 456 are followed and reinforcement is placed in a spiral pattern.
For foundations, IS 13920 and IS 2911 are followed and reinforcement is placed in a specific pattern based on the type ...
Pile foundations are used to transfer loads from structures to soil. Different types include driven piles, bored piles, and screw piles.
Driven piles are installed by hammering or vibrating them into the ground.
Bored piles are created by drilling a hole and then filling it with concrete and steel reinforcement.
Screw piles are twisted into the ground using a hydraulic motor.
Design considerations include soil type, load c...
Shear walls are designed to resist lateral forces. Detailing includes reinforcement placement and anchorage.
Design shear walls based on the building code requirements and structural analysis.
Select appropriate materials and thickness for the shear wall.
Detail the reinforcement placement and anchorage to ensure proper load transfer.
Provide adequate boundary elements and openings for ducts and pipes.
Consider seismic and ...
I have experience with various software for structural analysis.
STAAD.Pro
SAP2000
ETABS
ANSYS
AutoCAD Structural Detailing
To model raft foundation or shear wall in finite element method, one needs to follow certain steps.
First, create a 3D model of the foundation or wall using a CAD software.
Next, import the model into a finite element analysis software.
Define the material properties and boundary conditions.
Mesh the model to create finite elements.
Solve the model to obtain the stresses and displacements.
Finally, analyze the results and ma...
Water retaining structures are designed as per IS code and crack width is limited to ensure safety.
Design of water retaining structures involves determining the loads, selecting materials, and ensuring stability.
IS 3370 is the code used for design of water retaining structures in India.
The crack width for water retaining structures is limited to 0.2 mm to ensure safety and prevent leakage.
Various types of water retaini...
Yes, I have worked with both American and British codes.
I have experience working with the International Building Code (IBC) which is based on American codes.
I have also worked with British Standards (BS) such as BS 5950 for structural steel design.
I am familiar with the differences between the two codes and can adapt accordingly.
Different load combinations for RCC and Steel structures.
Load combinations for RCC structures include dead load, live load, wind load, earthquake load, and temperature load.
Load combinations for Steel structures include dead load, live load, wind load, earthquake load, temperature load, and snow load.
Load combinations are determined based on the design codes and standards applicable to the project.
The load combinations...
Yes, I have extensive experience in site inspections and creating progress and quality reports.
I have conducted site inspections for various projects in my previous roles.
I am proficient in creating detailed progress and quality reports based on my observations during site inspections.
I have also implemented corrective actions based on the findings of my inspections to ensure project success.
For example, in my previous...
To draw a bending moment and shear force diagram for a portal frame with lateral force and UDL.
Calculate the reactions at the supports
Determine the shear force and bending moment at each section
Plot the shear force and bending moment diagrams
Identify the maximum shear force and bending moment
Consider the sign conventions for shear force and bending moment
Use appropriate software or tools for accurate results
posted on 13 Dec 2022
I appeared for an interview before Dec 2021.
I appeared for an interview before Feb 2024.
I applied via Recruitment Consulltant and was interviewed before Sep 2021. There were 2 interview rounds.
posted on 28 Sep 2023
I applied via Walk-in
Load-bearing capacity in structural engineering refers to the maximum load a structure can support without failing.
Load-bearing capacity is determined by factors such as material strength, design, and support conditions.
Structural engineers calculate load-bearing capacity to ensure safety and prevent structural failure.
Examples of load-bearing elements include columns, beams, and foundations.
Load-bearing capacity can b...
A geotechnical investigation is conducted to assess the soil and rock conditions at a site for construction projects.
Determines the suitability of the site for construction
Identifies potential risks such as landslides, soil liquefaction, or sinkholes
Helps in designing foundations and earthworks
Involves drilling boreholes, taking soil samples, and conducting laboratory tests
Results in a geotechnical report with recommen
based on 1 interview
Interview experience
Electrical Engineer
19
salaries
| ₹1.8 L/yr - ₹4 L/yr |
Assistant Manager
11
salaries
| ₹3.2 L/yr - ₹7.5 L/yr |
Supervisor
11
salaries
| ₹2.1 L/yr - ₹4 L/yr |
Electrical Supervisor
10
salaries
| ₹1.2 L/yr - ₹3 L/yr |
Catering Executive
10
salaries
| ₹2.5 L/yr - ₹3.5 L/yr |
Sterling & Wilson
Nasser S. Al Hajri Corporation
Navayuga Engineering Company
B.L. Kashyap & Sons