I have 10 years of work experience in mechanical engineering.
Designed and implemented mechanical systems for various projects
Performed analysis and simulations to optimize performance
Collaborated with cross-functional teams to ensure project success
Managed and supervised junior engineers
Implemented cost-saving measures in manufacturing processes
Previous site infrastructure included data centers, networking equipment, servers, and storage systems.
Data centers were located in multiple regions for redundancy.
Networking equipment included routers, switches, and firewalls.
Servers were a mix of physical and virtual machines.
Storage systems used SAN and NAS technologies.
Backup and disaster recovery plans were in place.
Monitoring tools were used to track performance
Multiple scenarios of UPS DG CHILLER FAILURES
posted on 7 May 2022
I applied via Referral and was interviewed in Apr 2022. There were 3 interview rounds.
Transformer safety measures include proper grounding, regular maintenance, and protective devices.
Proper grounding to prevent electrical shock
Regular maintenance to prevent overheating and other issues
Protective devices such as fuses and circuit breakers to prevent overloading
Use of personal protective equipment (PPE) when working with transformers
Proper storage and handling of transformers to prevent damage
To calculate KWH to Amps, divide KWH by hours and then divide by voltage.
Divide KWH by hours to get KW
Divide KW by voltage to get Amps
Formula: Amps = KWH / (hours * voltage)
Example: 100 KWH used in 10 hours with 120V = 0.83 Amps
posted on 21 May 2023
I applied via Company Website and was interviewed in Apr 2023. There were 2 interview rounds.
I applied via Walk-in and was interviewed in Oct 2022. There were 2 interview rounds.
I applied via Referral and was interviewed before Oct 2020. There were 4 interview rounds.
Power factor is the ratio of real power to apparent power in an AC circuit.
It is a measure of how efficiently electrical power is being used.
It ranges from 0 to 1, with 1 being the most efficient.
A low power factor can result in higher energy costs and equipment damage.
Capacitors can be used to improve power factor.
Example: A motor with a power factor of 0.8 requires 1.25 times more current than a motor with a power fa
I appeared for an interview before Feb 2024.
based on 1 interview
Interview experience
based on 5 reviews
Rating in categories
Technical Supervisor
18
salaries
| ₹1.9 L/yr - ₹3.6 L/yr |
Electrical Supervisor
11
salaries
| ₹1.8 L/yr - ₹2.4 L/yr |
Supervisor
7
salaries
| ₹2 L/yr - ₹4 L/yr |
Electrician
7
salaries
| ₹2.3 L/yr - ₹2.5 L/yr |
HR Executive
6
salaries
| ₹2 L/yr - ₹3.8 L/yr |
Sodexo
ISS Facility Services
Compass Group Support Services
BVG India