HYOSUNG
Keertana Finserv Interview Questions and Answers
Q1. What is the good way to manage component cost in changing market in terms of material cost
The good way to manage component cost in changing market is to implement effective cost control strategies.
Regularly monitor market trends and fluctuations in material costs
Establish strong relationships with suppliers to negotiate better prices
Explore alternative materials or suppliers to reduce costs
Implement value engineering techniques to optimize component design and reduce material usage
Utilize cost analysis tools and software to track and analyze component costs
Collabo...read more
Q2. What is triple point & critical point
Triple point is the temperature and pressure at which a substance can exist in equilibrium as a solid, liquid, and gas. Critical point is the temperature and pressure at which a substance's distinct phases merge into a single phase.
Triple point is the unique combination of temperature and pressure at which all three phases of a substance coexist in equilibrium.
Critical point is the temperature and pressure at which a substance's distinct phases merge into a single phase, know...read more
Q3. What is law of conservation of mass
The law of conservation of mass states that mass cannot be created or destroyed in a chemical reaction.
Mass is neither created nor destroyed in a chemical reaction
The total mass of the reactants must equal the total mass of the products
This law is a fundamental principle in chemistry and is based on the fact that atoms are neither created nor destroyed in a chemical reaction
Q4. Important parts of pumps
Important parts of pumps include impeller, casing, shaft, and bearings.
Impeller: Rotating component that imparts energy to the fluid.
Casing: Encloses the impeller and directs the flow of fluid.
Shaft: Transmits the rotational motion from the motor to the impeller.
Bearings: Support the shaft and reduce friction.
Other parts may include seals, volute, and motor.
Q5. Important parts of cooling tower
Important parts of a cooling tower include the fill media, drift eliminators, fan, water distribution system, and the shell.
Fill media: It provides a large surface area for heat transfer by increasing the contact between air and water.
Drift eliminators: These prevent the loss of water droplets from the tower, reducing water consumption.
Fan: It draws air through the tower, facilitating the cooling process.
Water distribution system: It evenly distributes water over the fill med...read more
Q6. Design heat exchanger or formulas
Designing a heat exchanger involves understanding heat transfer principles and selecting appropriate materials and configurations.
Understand the heat transfer requirements and constraints
Select appropriate materials for the heat exchanger based on the operating conditions
Choose a suitable configuration such as shell and tube, plate heat exchanger, or finned tube heat exchanger
Calculate the heat transfer area and fluid flow rates to meet the desired temperature requirements
Con...read more
Q7. POLE FACTOR IN CB
POLE FACTOR IN CB refers to the Project, Organization, Leadership, and Environment factors that influence the success of a project.
Project Factor: Consider the scope, timeline, budget, and resources allocated to the project.
Organization Factor: Evaluate the organizational structure, culture, and support for the project.
Leadership Factor: Assess the leadership style, communication, and decision-making within the project team.
Environment Factor: Take into account external facto...read more