Filter interviews by
I applied via Walk-in and was interviewed before Jan 2024. There were 2 interview rounds.
Optimizing application execution time involves identifying bottlenecks and implementing efficient algorithms.
Identify performance bottlenecks using profiling tools like Chrome DevTools or JProfiler.
Optimize algorithms and data structures to reduce time complexity.
Use caching mechanisms to store frequently accessed data and reduce redundant computations.
Parallelize tasks to take advantage of multi-core processors.
Consid...
Implemented a new software system to improve efficiency in data analysis
Identified the need for a more streamlined process for data analysis
Researched and evaluated different software options
Collaborated with team members to implement and test the new system
Provided training and support to ensure successful adoption by the team
Seeking new challenges and growth opportunities
Desire for career advancement
Limited opportunities for growth in previous role
Looking for new challenges and projects to work on
In 5 years, I see myself leading a team of engineers, driving innovative projects, and contributing to the growth of the company.
Leading a team of engineers towards successful project completion
Driving innovative projects and implementing new technologies
Contributing to the growth and success of the company
Continuing to develop my leadership and technical skills
I applied via Naukri.com and was interviewed in Aug 2022. There were 2 interview rounds.
As an Engineering Manager, my duties and responsibilities include overseeing engineering projects, managing a team of engineers, setting goals and objectives, ensuring project deadlines are met, and collaborating with other departments.
Oversee engineering projects and ensure they are completed on time and within budget
Manage a team of engineers, providing guidance, support, and mentorship
Set goals and objectives for th...
I applied via Naukri.com and was interviewed before Jul 2020. There were 4 interview rounds.
Chiller plant operation involves a process of cooling water using a refrigerant and circulating it through a closed loop system.
The chiller plant consists of a compressor, condenser, evaporator, and expansion valve.
The compressor compresses the refrigerant gas, which then flows to the condenser where it is cooled and condensed into a liquid.
The liquid refrigerant then flows to the evaporator where it absorbs heat from ...
DG sets are safe if maintained properly. They work by converting fuel into electrical energy through combustion.
DG sets should be installed in well-ventilated areas to prevent carbon monoxide poisoning.
Regular maintenance and servicing is necessary to ensure safe operation.
Proper grounding and earthing is essential to prevent electrical hazards.
DG sets should be equipped with safety features such as automatic shutdown ...
Dry transformers are safe due to their insulation system and lack of flammable liquids.
Dry transformers use solid insulation materials to prevent electrical arcing and fires.
They do not contain flammable liquids like oil-filled transformers.
Dry transformers are often used in indoor settings where fire safety is a concern.
Regular maintenance and testing is important to ensure the safety and efficiency of dry transformer
Dry type transformers are considered for safety, environmental, and maintenance reasons.
Dry type transformers are safer than oil-filled transformers as they do not pose a fire hazard.
They are also more environmentally friendly as they do not contain oil that can leak and cause pollution.
Dry type transformers require less maintenance than oil-filled transformers as they do not need oil testing or replacement.
They are al...
Fire alarm system detects fire and alerts occupants and emergency services.
Fire alarm system consists of smoke detectors, heat detectors, and manual pull stations.
When smoke or heat is detected, the alarm sounds and alerts occupants to evacuate.
The alarm also sends a signal to the monitoring station, which alerts emergency services.
Regular maintenance and testing of the system is necessary to ensure proper functioning.
The main contactor is connected first in a star delta starter.
The main contactor is connected to the three-phase power supply.
The main contactor is responsible for supplying power to the motor.
The delta contactor is then connected to the motor windings.
The star contactor is connected last to complete the circuit.
This method is used to reduce the starting current of the motor.
Chiller plant de-scaling process involves removing mineral deposits from the chiller tubes to improve efficiency.
The process involves shutting down the chiller plant and draining the water from the system.
Acidic solutions are then circulated through the chiller tubes to dissolve the mineral deposits.
After the solution has been circulated for a specific amount of time, it is drained and the chiller tubes are flushed wit...
Elevator flywheel stores kinetic energy to provide backup power during power outages.
Flywheel is connected to the elevator motor and spins continuously.
During normal operation, the flywheel stores kinetic energy.
In case of a power outage, the flywheel continues to spin and provides backup power to the elevator motor.
This allows the elevator to safely descend to the nearest floor and open its doors.
Flywheels are commonl...
To connect a LAN cable connector, follow these steps:
Identify the LAN port on your device
Insert the connector into the port until it clicks into place
Ensure the connector is securely connected by gently tugging on the cable
Repeat the process on the other end of the cable, connecting it to the router or modem
Check for a stable internet connection
Oil based transformer BDV test unit is a device used to measure the breakdown voltage of transformer oil.
BDV test unit is used to determine the quality of transformer oil.
It measures the voltage at which the oil breaks down and becomes conductive.
This test is important to ensure the proper functioning of the transformer.
The test unit applies a voltage to the oil and measures the current flow.
If the current exceeds a ce...
I applied via Naukri.com and was interviewed in Aug 2022. There were 2 interview rounds.
As an Engineering Manager, my duties and responsibilities include overseeing engineering projects, managing a team of engineers, setting goals and objectives, ensuring project deadlines are met, and collaborating with other departments.
Oversee engineering projects and ensure they are completed on time and within budget
Manage a team of engineers, providing guidance, support, and mentorship
Set goals and objectives for th...
I applied via Naukri.com and was interviewed before Jul 2020. There were 4 interview rounds.
Chiller plant operation involves a process of cooling water using a refrigerant and circulating it through a closed loop system.
The chiller plant consists of a compressor, condenser, evaporator, and expansion valve.
The compressor compresses the refrigerant gas, which then flows to the condenser where it is cooled and condensed into a liquid.
The liquid refrigerant then flows to the evaporator where it absorbs heat from ...
DG sets are safe if maintained properly. They work by converting fuel into electrical energy through combustion.
DG sets should be installed in well-ventilated areas to prevent carbon monoxide poisoning.
Regular maintenance and servicing is necessary to ensure safe operation.
Proper grounding and earthing is essential to prevent electrical hazards.
DG sets should be equipped with safety features such as automatic shutdown ...
Dry transformers are safe due to their insulation system and lack of flammable liquids.
Dry transformers use solid insulation materials to prevent electrical arcing and fires.
They do not contain flammable liquids like oil-filled transformers.
Dry transformers are often used in indoor settings where fire safety is a concern.
Regular maintenance and testing is important to ensure the safety and efficiency of dry transformer
Dry type transformers are considered for safety, environmental, and maintenance reasons.
Dry type transformers are safer than oil-filled transformers as they do not pose a fire hazard.
They are also more environmentally friendly as they do not contain oil that can leak and cause pollution.
Dry type transformers require less maintenance than oil-filled transformers as they do not need oil testing or replacement.
They are al...
Fire alarm system detects fire and alerts occupants and emergency services.
Fire alarm system consists of smoke detectors, heat detectors, and manual pull stations.
When smoke or heat is detected, the alarm sounds and alerts occupants to evacuate.
The alarm also sends a signal to the monitoring station, which alerts emergency services.
Regular maintenance and testing of the system is necessary to ensure proper functioning.
The main contactor is connected first in a star delta starter.
The main contactor is connected to the three-phase power supply.
The main contactor is responsible for supplying power to the motor.
The delta contactor is then connected to the motor windings.
The star contactor is connected last to complete the circuit.
This method is used to reduce the starting current of the motor.
Chiller plant de-scaling process involves removing mineral deposits from the chiller tubes to improve efficiency.
The process involves shutting down the chiller plant and draining the water from the system.
Acidic solutions are then circulated through the chiller tubes to dissolve the mineral deposits.
After the solution has been circulated for a specific amount of time, it is drained and the chiller tubes are flushed wit...
Elevator flywheel stores kinetic energy to provide backup power during power outages.
Flywheel is connected to the elevator motor and spins continuously.
During normal operation, the flywheel stores kinetic energy.
In case of a power outage, the flywheel continues to spin and provides backup power to the elevator motor.
This allows the elevator to safely descend to the nearest floor and open its doors.
Flywheels are commonl...
To connect a LAN cable connector, follow these steps:
Identify the LAN port on your device
Insert the connector into the port until it clicks into place
Ensure the connector is securely connected by gently tugging on the cable
Repeat the process on the other end of the cable, connecting it to the router or modem
Check for a stable internet connection
Oil based transformer BDV test unit is a device used to measure the breakdown voltage of transformer oil.
BDV test unit is used to determine the quality of transformer oil.
It measures the voltage at which the oil breaks down and becomes conductive.
This test is important to ensure the proper functioning of the transformer.
The test unit applies a voltage to the oil and measures the current flow.
If the current exceeds a ce...
based on 1 interview
Interview experience
based on 2 reviews
Rating in categories
Software Engineer
48
salaries
| ₹3 L/yr - ₹12.5 L/yr |
Senior Software Engineer
38
salaries
| ₹6.1 L/yr - ₹26.6 L/yr |
Schedule Editor
25
salaries
| ₹2.9 L/yr - ₹4.9 L/yr |
MIS Executive
24
salaries
| ₹2.9 L/yr - ₹4.4 L/yr |
Editor
22
salaries
| ₹2.8 L/yr - ₹5 L/yr |
Nielsen
comScore
Kantar
Dun & Bradstreet