Filter interviews by
To calibrate pressure gauges, vacuum gauges, and compound gauges, follow these steps:
Use a known reference pressure source to compare the readings of the gauges.
Adjust the gauges if there is any deviation from the reference pressure.
Repeat the process multiple times to ensure accuracy.
Document the calibration process and results for future reference.
Perform regular calibrations to maintain accuracy.
Example: For pr...
To check door interlock systems, inspect the physical components, test the electrical connections, and verify proper functioning.
Inspect the door hinges, latches, and locks for any damage or misalignment.
Check the wiring connections and ensure they are secure and not damaged.
Test the interlock switch by opening and closing the door to see if it activates properly.
Verify that the interlock system prevents the door ...
There are several types of flow meters used in various industries to measure the flow rate of fluids or gases.
Some common types of flow meters include electromagnetic flow meters, ultrasonic flow meters, turbine flow meters, and positive displacement flow meters.
Electromagnetic flow meters use Faraday's law of electromagnetic induction to measure the flow rate of conductive fluids.
Ultrasonic flow meters utilize ul...
Calibration of RTDs involves comparing the sensor's output to a known reference and adjusting it accordingly.
RTDs (Resistance Temperature Detectors) are calibrated to ensure accurate temperature measurements.
Calibration involves comparing the RTD's resistance values at different temperatures to a known reference.
Adjustments are made to the RTD's output signal to align it with the reference values.
Calibration can b...
Calibrating temperature indicators involves adjusting them to ensure accurate readings.
Calibration of temperature indicators involves comparing their readings to a known standard.
Adjustments are made to the indicators to align their readings with the standard.
Calibration may involve adjusting the zero point and span of the indicators.
Examples of temperature indicators include thermometers, temperature sensors, and...
Calibration is the process of adjusting or verifying the accuracy of a measuring instrument or device.
Calibration ensures that measurements taken by an instrument are accurate and reliable.
It involves comparing the measurements of a device to a known standard.
Calibration may involve adjusting the device to bring it in line with the standard.
It is important in various fields like engineering, manufacturing, and sci...
I appeared for an interview in Aug 2017.
Calibration is the process of adjusting or verifying the accuracy of a measuring instrument or device.
Calibration ensures that measurements taken by an instrument are accurate and reliable.
It involves comparing the measurements of a device to a known standard.
Calibration may involve adjusting the device to bring it in line with the standard.
It is important in various fields like engineering, manufacturing, and scientif...
Calibrating temperature indicators involves adjusting them to ensure accurate readings.
Calibration of temperature indicators involves comparing their readings to a known standard.
Adjustments are made to the indicators to align their readings with the standard.
Calibration may involve adjusting the zero point and span of the indicators.
Examples of temperature indicators include thermometers, temperature sensors, and temp...
Calibration of RTDs involves comparing the sensor's output to a known reference and adjusting it accordingly.
RTDs (Resistance Temperature Detectors) are calibrated to ensure accurate temperature measurements.
Calibration involves comparing the RTD's resistance values at different temperatures to a known reference.
Adjustments are made to the RTD's output signal to align it with the reference values.
Calibration can be don...
There are several types of flow meters used in various industries to measure the flow rate of fluids or gases.
Some common types of flow meters include electromagnetic flow meters, ultrasonic flow meters, turbine flow meters, and positive displacement flow meters.
Electromagnetic flow meters use Faraday's law of electromagnetic induction to measure the flow rate of conductive fluids.
Ultrasonic flow meters utilize ultraso...
To check door interlock systems, inspect the physical components, test the electrical connections, and verify proper functioning.
Inspect the door hinges, latches, and locks for any damage or misalignment.
Check the wiring connections and ensure they are secure and not damaged.
Test the interlock switch by opening and closing the door to see if it activates properly.
Verify that the interlock system prevents the door from ...
To calibrate pressure gauges, vacuum gauges, and compound gauges, follow these steps:
Use a known reference pressure source to compare the readings of the gauges.
Adjust the gauges if there is any deviation from the reference pressure.
Repeat the process multiple times to ensure accuracy.
Document the calibration process and results for future reference.
Perform regular calibrations to maintain accuracy.
Example: For pressur...
Top trending discussions
I appeared for an interview before Sep 2021.
I applied via Recruitment Consulltant and was interviewed before Aug 2021. There were 3 interview rounds.
I appeared for an interview before Feb 2021.
I am a passionate engineer with a strong background in software development and a keen interest in innovative technology solutions.
Education: Bachelor's degree in Computer Engineering from XYZ University.
Experience: 3 years as a software developer at ABC Corp, where I led a team to develop a mobile application that increased user engagement by 30%.
Skills: Proficient in programming languages such as Python, Java, and C+...
I applied via Naukri.com and was interviewed in Mar 2022. There were 4 interview rounds.
Eye Q test
I applied via Naukri.com and was interviewed in Apr 2022. There were 2 interview rounds.
I applied via Walk-in and was interviewed in May 2024. There were 2 interview rounds.
My name Devender singh tanwar and belong from palwal haryana . I have done work in poly medicure company from 2013 to 2022..I was good employee of this company.
Cooling tower efficiency is a measure of how well a cooling tower is able to remove heat from a system.
Cooling tower efficiency is typically calculated as the ratio of actual heat transfer to the maximum possible heat transfer.
Factors that affect cooling tower efficiency include air and water flow rates, temperature differentials, and fouling of heat transfer surfaces.
Higher efficiency means the cooling tower is able t...
I appeared for an interview before Jun 2024, where I was asked the following questions.
I applied via Recruitment Consulltant and was interviewed in Feb 2023. There were 2 interview rounds.
I am a passionate engineer with a strong background in software development and a keen interest in innovative technology solutions.
Education: Bachelor's degree in Computer Engineering from XYZ University.
Experience: 3 years as a software developer at ABC Corp, where I led a team to develop a mobile application that increased user engagement by 30%.
Skills: Proficient in programming languages such as Python, Java, and C+...
based on 1 review
Rating in categories
Executive
443
salaries
| ₹3.9 L/yr - ₹8 L/yr |
Chemist
425
salaries
| ₹2.1 L/yr - ₹5.3 L/yr |
Assistant Manager
412
salaries
| ₹5.8 L/yr - ₹12 L/yr |
Junior Executive
411
salaries
| ₹2.8 L/yr - ₹7.1 L/yr |
Senior Executive
294
salaries
| ₹5 L/yr - ₹9.6 L/yr |
Poly Medicure
Medtronic
Alcon
Romsons Group Of Industries