I applied via Walk-in and was interviewed in Sep 2024. There was 1 interview round.
I applied via Referral and was interviewed in Aug 2021. There was 1 interview round.
Column efficiency can be evaluated by measuring the resolution, peak asymmetry, and plate count.
Resolution can be calculated by dividing the distance between two peaks by the sum of their peak widths.
Peak asymmetry can be determined by measuring the distance between the peak maximum and the point where the slope of the peak is half of the maximum slope.
Plate count can be calculated by dividing the column length by the
Ion exchange chromatography separates molecules based on their charge.
Ion exchange chromatography uses a resin with charged functional groups to attract and bind molecules with opposite charges.
The bound molecules can then be eluted by changing the pH or salt concentration of the solution.
This technique is commonly used in downstream processing to purify proteins and other biomolecules.
Examples of ion exchange resins i...
Packing and unpacking a column involves filling and emptying the column with the desired material.
Packing the column involves adding the desired material to the column and ensuring it is evenly distributed.
Unpacking the column involves removing the material from the column, usually by flushing it with a suitable solvent.
The packing material used depends on the type of column and the desired separation.
Common packing ma...
The chromatography software and version used is dependent on the specific process and equipment being utilized.
The software and version may vary depending on the manufacturer of the chromatography equipment.
Common chromatography software includes Unicorn, Chromeleon, and Empower.
The version used may also depend on the age of the equipment and compatibility with newer software.
The software is used to control the chromat
Flux in TFF refers to the rate of flow of the liquid through the membrane during filtration.
Flux is measured in volume per unit area per unit time.
It is influenced by factors such as pressure, temperature, and membrane pore size.
High flux rates can lead to membrane fouling and reduced filtration efficiency.
NWP stands for nominal molecular weight cut-off in TFF.
NWP is a parameter used in tangential flow filtration (TFF) to determine the size of molecules that can pass through the membrane.
It is the molecular weight at which 90% of the molecules are retained by the membrane.
NWP is important in downstream processing to ensure the desired molecules are separated from impurities.
For example, if the target molecule has a molec...
Column volume can be calculated by dividing the total bed volume by the packing factor.
Determine the total bed volume of the column
Calculate the packing factor of the column
Divide the total bed volume by the packing factor to get the column volume
Volumetric flow rate is the volume of fluid passing through a given point per unit time, while linear flow rate is the distance traveled by the fluid per unit time.
Volumetric flow rate is measured in units of volume per unit time, such as liters per minute or gallons per hour.
Linear flow rate is measured in units of distance per unit time, such as meters per second or feet per minute.
Volumetric flow rate is used to des...
Top trending discussions
I applied via Naukri.com
posted on 7 Jun 2020
I applied via Naukri.com and was interviewed in Dec 2019. There were 4 interview rounds.
I applied via Referral and was interviewed before May 2018. There were 5 interview rounds.
posted on 5 Feb 2021
I applied via Naukri.com and was interviewed before Feb 2020. There was 1 interview round.
I applied via Company Website and was interviewed in Mar 2022. There were 2 interview rounds.
I bring strong leadership, analytical skills, and industry knowledge to drive team success and enhance operational efficiency.
Proven leadership experience: Managed a team of 10, improving productivity by 20% through effective delegation and motivation.
Strong analytical skills: Utilized data analysis to identify market trends, leading to a 15% increase in sales over six months.
Industry knowledge: Over five years in the ...
Method validation is a process to confirm that an analytical method is suitable for its intended use.
Define the purpose and scope of the method
Select appropriate validation characteristics
Develop a validation plan
Execute the plan and document the results
Evaluate the results and determine if the method is suitable for use
QMS process involves planning, execution, monitoring, and improvement of quality systems. OOS investigation involves identifying root cause of out-of-specification results.
QMS process includes defining quality policies and objectives, identifying processes and resources, implementing controls, and monitoring performance.
OOS investigation involves documenting the event, identifying the root cause, implementing correctiv...
I applied via Company Website and was interviewed in Dec 2024. There was 1 interview round.
posted on 11 Jan 2022
I applied via Naukri.com and was interviewed in Jul 2021. There were 3 interview rounds.
based on 2 interviews
Interview experience
based on 70 reviews
Rating in categories
Junior Executive
46
salaries
| ₹2.4 L/yr - ₹4.1 L/yr |
Executive
36
salaries
| ₹3.4 L/yr - ₹6.1 L/yr |
Senior Executive
26
salaries
| ₹5.2 L/yr - ₹8 L/yr |
Junior Research Associate
20
salaries
| ₹2.6 L/yr - ₹3.6 L/yr |
Assistant Manager
20
salaries
| ₹7.5 L/yr - ₹10 L/yr |
Aragen Life Sciences
Parexel International
Fortrea Development India Private Limited
Syneos Health