What is ph meter?
What is buffer solution?
Autoclave definition
Autoclave principal
A pH meter is a device used to measure the acidity or alkalinity of a solution.
A pH meter consists of a probe that measures the voltage difference between a reference electrode and a glass electrode.
The pH value is determined by comparing the voltage difference to a known standard.
pH meters are commonly used in laboratories, agriculture, and water treatment to monitor and control pH levels.
For example, in a laboratory,...
Top trending discussions
I applied via Company Website and was interviewed before Dec 2023. There were 2 interview rounds.
Safety is crucial in any work environment to prevent accidents and injuries.
Safety ensures the well-being of employees and prevents accidents
Following safety protocols reduces the risk of injuries and illnesses
Safety measures promote a positive work culture and increase productivity
Regular safety training and equipment maintenance are essential
Examples: wearing personal protective equipment, following lockout/tagout pr
I applied via LinkedIn and was interviewed in Jan 2022. There were 2 interview rounds.
Reflux is used in distillation column for temperature and purity maintenance in product.
Reflux helps in maintaining a constant temperature in the distillation column.
It also helps in achieving a higher purity of the product by preventing the vaporized product from escaping the column.
Reflux is achieved by condensing some of the vaporized product and returning it back to the column.
This process helps in achieving a more...
Safety in IBC in charge in reactor involves various measures such as IBC in property arthing plate, vent, interlock, PPE, etc.
IBC in property arthing plate is used to prevent static electricity buildup and discharge.
Ventilation systems are installed to ensure proper air circulation and prevent the accumulation of hazardous gases.
Interlock systems are implemented to ensure safe operation and prevent unauthorized access.
...
Increase vacuum and temperature to recover any remaining chemical.
Increase vacuum to lower the boiling point of the chemical.
Raise temperature to increase the vapor pressure of the chemical.
Use a condenser to collect the vapor and recover the chemical.
Repeat the process until no more chemical can be recovered.
Dispose of any remaining waste safely and responsibly.
DCS stands for Distributed Control System and includes open loop, closed loop, and cascade loop control strategies.
DCS is a computerized control system used to manage and automate industrial processes.
Open loop control is a control strategy where the output is not measured or compared to the input.
Closed loop control is a control strategy where the output is measured and compared to the input to adjust the process.
Casc...
I applied via Company Website and was interviewed in Oct 2021. There was 1 interview round.
based on 1 review
Rating in categories
Executive
97
salaries
| ₹3 L/yr - ₹7.2 L/yr |
Senior Executive
94
salaries
| ₹4 L/yr - ₹10 L/yr |
Research Associate
57
salaries
| ₹2.5 L/yr - ₹7.7 L/yr |
Assistant Manager
48
salaries
| ₹6.5 L/yr - ₹13.7 L/yr |
Apprentice
46
salaries
| ₹1 L/yr - ₹2 L/yr |
Syngene International
Biocon Limited
DRJ & CO
Wockhardt