Filter interviews by
I applied via Naukri.com and was interviewed in Sep 2023. There were 7 interview rounds.
IDT mechanical protection refers to the mechanical protection provided to insulated conductors or cables to prevent damage.
IDT stands for Insulated Dead-end Termination
Mechanical protection can include using conduits, cable trays, or protective sleeves
It is important to ensure proper mechanical protection to prevent damage to the insulation and conductors
Examples of mechanical protection methods include using PVC condu...
String fault solution refers to troubleshooting and fixing issues related to electrical wiring or connections.
Identify the location of the string fault by using a multimeter to test for continuity.
Inspect the wiring for any visible damage or loose connections.
Repair or replace the faulty wiring or connections to resolve the issue.
Test the circuit again to ensure the string fault has been successfully resolved.
Module VOC and VMP combination refers to the open circuit voltage and maximum power voltage of a solar panel.
VOC (Voltage Open Circuit) is the maximum voltage that a solar panel can produce when there is no load connected.
VMP (Voltage Maximum Power) is the voltage at which the solar panel produces the maximum power output.
The combination of VOC and VMP is important for determining the efficiency and performance of a so...
posted on 24 Apr 2024
I applied via Recruitment Consulltant and was interviewed before Apr 2023. There were 2 interview rounds.
I applied via Other and was interviewed before Sep 2020. There was 1 interview round.
Types of testing for switchyard equipment
Functional testing
Performance testing
Integration testing
Acceptance testing
Reliability testing
Substations are classified based on their functions and voltage levels.
Distribution Substation
Transmission Substation
Collector Substation
Switching Substation
Converter Substation
Customer Substation
I applied via Recruitment Consultant and was interviewed in Mar 2020. There were 3 interview rounds.
Explanation of k factors used for wind load calculation with values for a site.
K factors are used to calculate wind loads on structures.
K factors depend on the shape, size, and orientation of the structure.
Values for K factors can be found in ASCE 7-16 or other wind load standards.
Examples of K factors include Kd for wind directionality and Kz for height above ground.
Values for K factors can vary depending on the speci
kd factor is taken as 0.9 instead of 1 to account for losses in the system.
kd factor is used in control valve sizing calculations.
It accounts for the pressure drop across the valve and the piping system.
The value of kd factor is less than 1 to account for losses in the system.
These losses can be due to friction, turbulence, or other factors.
For example, if the kd factor is 0.9, it means that the valve will have a 10% p
Various types of steel coatings/materials are available in the market, including galvanized, aluminized, and stainless steel.
Galvanized steel coating is made of zinc and provides excellent corrosion resistance.
Aluminized steel coating is made of aluminum and silicon and is heat-resistant.
Stainless steel is an alloy of iron, carbon, and other elements, and is highly resistant to corrosion and staining.
Other coatings/mat...
Steel sheets are available in various thicknesses depending on the application.
The thickness of steel sheets ranges from 30 gauge to 7 gauge.
Thinner sheets are used for applications such as roofing and siding, while thicker sheets are used for structural purposes.
Common thicknesses include 16 gauge, 14 gauge, 12 gauge, and 10 gauge.
The thickness of a steel sheet can also be measured in millimeters or inches.
The thickne...
Factors to consider prior to finalizing land for construction.
Location and accessibility
Zoning and land use regulations
Soil and environmental conditions
Availability of utilities and infrastructure
Cost and budget
Future development plans and potential risks
Eden Renewables interview questions for popular designations
Top trending discussions
I applied via Campus Placement and was interviewed before Nov 2020. There were 5 interview rounds.
HVDC stands for High Voltage Direct Current. It is a system used for transmitting high voltage electricity over long distances.
HVDC systems are used to transmit electricity over long distances with minimal losses.
They are more efficient than traditional AC systems for long-distance transmission.
HVDC systems use converters to convert AC power to DC power and vice versa.
Examples of HVDC systems include the Itaipu HVDC sy...
A rectifier is an electronic device that converts AC to DC.
Rectifiers are commonly used in power supplies to convert AC voltage to DC voltage.
They can be made using diodes or other semiconductor devices.
Rectifiers are essential for many electronic devices to function properly.
Examples of rectifiers include bridge rectifiers, half-wave rectifiers, and full-wave rectifiers.
I applied via Approached by Company and was interviewed before Jul 2021. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Jun 2021. There was 1 interview round.
I have 5 years of experience in sales, working for a leading technology company.
Worked as a Sales Executive for XYZ Technology for 5 years
Managed a portfolio of key accounts and consistently exceeded sales targets
Developed and maintained strong relationships with clients, resulting in repeat business
Collaborated with cross-functional teams to develop and implement effective sales strategies
Provided excellent customer s...
I have achieved consistent sales growth, exceeding targets by 20% for three consecutive years.
Consistently exceeded sales targets by 20% for three consecutive years
Developed and implemented effective sales strategies resulting in increased revenue
Built and maintained strong relationships with key clients, leading to repeat business
Received multiple awards for top sales performance
I will achieve the target by implementing a strategic sales plan, building strong relationships with clients, and consistently meeting and exceeding sales goals.
Developing a comprehensive sales strategy that includes identifying target markets, setting sales goals, and creating a plan to reach those goals.
Building and maintaining strong relationships with clients by providing excellent customer service, understanding t...
I was interviewed in Sep 2020.
I applied via Approached by Company and was interviewed before Jul 2021. There were 3 interview rounds.
GD regarding Renewable energy and assessment
posted on 21 Jul 2024
Some of the top questions asked at the Eden Renewables interview -
based on 2 interviews
Interview experience
based on 44 reviews
Rating in categories
Senior Engineer
20
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
14
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
12
salaries
| ₹0 L/yr - ₹0 L/yr |
Electrical Technician
9
salaries
| ₹0 L/yr - ₹0 L/yr |
Electrical Engineer
8
salaries
| ₹0 L/yr - ₹0 L/yr |
Adani Green Energy
Azure Power
ReNew
Hero Future Energies