Filter interviews by
I applied via Naukri.com
Top trending discussions
I applied via LinkedIn and was interviewed in Apr 2024. There was 1 interview round.
I applied via Company Website and was interviewed before Feb 2023. There were 2 interview rounds.
A rectifier is an electrical device that converts alternating current (AC) to direct current (DC).
Rectifiers are commonly used in power supplies to convert AC voltage to DC voltage.
They are made up of diodes, which allow current to flow in only one direction.
Rectifiers can be half-wave or full-wave, depending on the number of diodes used.
Examples of rectifiers include bridge rectifiers, vacuum tube rectifiers, and soli
SCR stands for Selective Catalytic Reduction. It is a technology used to reduce nitrogen oxide emissions from diesel engines.
SCR is a process that uses a catalyst to convert nitrogen oxides (NOx) into nitrogen (N2) and water (H2O).
It involves injecting a urea-based solution, known as diesel exhaust fluid (DEF), into the exhaust stream.
The DEF reacts with the NOx in the presence of the catalyst, breaking it down into ha...
I applied via Naukri.com and was interviewed before Mar 2022. There were 2 interview rounds.
Manegement Topic of running our company
Current transformer secondary is open to prevent damage to the transformer and connected equipment.
An open secondary circuit prevents excessive current flow and protects the transformer from damage.
It allows for safe measurement and monitoring of current without risk of short circuits.
An open secondary also prevents damage to connected equipment by isolating it from high currents.
In case of a fault or overload, an open...
CT and PT are both electrical devices used in power systems, but they have different functions and applications.
CT stands for Current Transformer, while PT stands for Potential Transformer.
CTs are used to measure and transform high currents into manageable levels for instruments and protective relays.
PTs are used to measure and transform high voltages into low voltages for instruments and protective relays.
CTs are typi...
The single line diagram for HY to LT Panel diagram is a visual representation of the electrical connections and components in the system.
The single line diagram shows the flow of electrical power from the HY (High Voltage) side to the LT (Low Tension) side.
It includes the main components such as transformers, circuit breakers, switches, and control devices.
The diagram also indicates the interconnections between differe...
The number of circuit breakers used in an electrical system varies depending on the size and complexity of the system.
The number of circuit breakers used in an electrical system depends on factors such as the size of the system, the number of circuits, and the specific requirements of the building or facility.
Residential electrical systems typically have a main circuit breaker at the electrical panel, along with indivi...
In a power failure situation, effective management involves ensuring safety, communication, and contingency planning.
Ensure the safety of employees and customers by providing emergency lighting and clear evacuation procedures.
Maintain open lines of communication with staff, customers, and relevant authorities to provide updates and coordinate actions.
Implement contingency plans such as backup power sources, alternative...
B check in a generator refers to a comprehensive inspection and maintenance procedure to ensure its proper functioning.
B check involves a thorough examination of the generator's components, including the engine, fuel system, cooling system, electrical system, and control panel.
It includes tasks such as checking for leaks, inspecting belts and hoses, testing the battery, cleaning or replacing filters, and verifying prop...
Transformers require protection to prevent damage from faults, overloads, and external disturbances.
Overcurrent protection: Detects excessive current flow, triggering circuit breakers.
Differential protection: Compares input and output currents to identify faults.
Temperature monitoring: Uses sensors to prevent overheating, ensuring safe operation.
Bushing protection: Monitors insulation integrity to prevent failures.
Grou...
In a substation, I manage operations, ensure safety, and maintain equipment for efficient power distribution.
Monitor and control electrical equipment to ensure optimal performance.
Conduct regular inspections and maintenance of transformers and circuit breakers.
Implement safety protocols to protect personnel and equipment.
Coordinate with utility companies for power distribution and outages.
Respond to emergencies and tro
Circuit breakers (CB) protect electrical circuits from overloads and faults, ensuring safety and reliability.
Miniature Circuit Breaker (MCB): Automatically switches off during overloads, e.g., in residential wiring.
Molded Case Circuit Breaker (MCCB): Used for medium voltage applications, e.g., industrial machinery.
Earth Leakage Circuit Breaker (ELCB): Protects against earth faults, e.g., in wet areas like bathrooms.
Res...
I applied via Campus Placement
Variant of Binary Search
Implement a binary search with a twist, such as searching for a range of values instead of a single value
Modify the binary search algorithm to handle duplicates in the array
Consider implementing a binary search for a rotated sorted array
posted on 24 Mar 2023
I applied via Campus Placement and was interviewed in Sep 2022. There were 4 interview rounds.
Basics of electronics and two coding questions
based on 1 review
Rating in categories
Production Engineer
12
salaries
| ₹1.5 L/yr - ₹4 L/yr |
Electrical Maintenance Engineer
9
salaries
| ₹2.8 L/yr - ₹3.5 L/yr |
Maintenance Engineer
9
salaries
| ₹1.8 L/yr - ₹4 L/yr |
Electronics Maintenance Engineer
7
salaries
| ₹2.5 L/yr - ₹3.2 L/yr |
Design Engineer
7
salaries
| ₹1.8 L/yr - ₹3.5 L/yr |
JBS Enterprises
Essae Digitronics
La-Gajjar Machineries
East India Technologies