i
Blue Star
Filter interviews by
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
I applied via Campus Placement and was interviewed in Nov 2021. There were 6 interview rounds.
Thermodynamics is the study of energy and its transformations in relation to heat and work.
It deals with the behavior of energy and its conversion from one form to another.
It involves the study of heat transfer, work, and the properties of substances.
Thermodynamics is essential in designing and analyzing various mechanical systems.
Examples include the study of engines, refrigeration systems, and power plants.
Diesel engines are commonly used in trains.
Trains typically use diesel engines due to their high torque and fuel efficiency.
Electric engines are also used in some trains, especially in urban areas.
Steam engines were used in the past but are now rare.
Hybrid engines that combine diesel and electric power are becoming more common.
The type of engine used in a train depends on factors such as the distance it travels and the
P,V and T,S diagrams are graphical representations of thermodynamic processes.
P,V diagram shows the relationship between pressure and volume.
T,S diagram shows the relationship between temperature and entropy.
P,V and T,S diagrams are useful in analyzing thermodynamic cycles.
P,V and T,S diagrams can be used to determine the efficiency of a heat engine.
P,V and T,S diagrams are commonly used in the design of power plants a
Adiabatic process is a thermodynamic process where no heat is exchanged with the surroundings. Hyperbolic process is a type of adiabatic process.
Adiabatic process occurs when there is no heat transfer between the system and its surroundings
Hyperbolic process is a type of adiabatic process where the pressure and volume of a gas are inversely proportional
Adiabatic compression of a gas can cause an increase in temperature
...
IDU and ODU are abbreviations used in air conditioning systems. IDU stands for Indoor Unit and ODU stands for Outdoor Unit.
IDU is the unit that is installed inside the room or building, while ODU is installed outside.
IDU is responsible for cooling or heating the air inside the room, while ODU is responsible for dissipating the heat outside.
IDU is connected to ODU through refrigerant pipes and electrical cables.
Examples...
Enthalpy is the heat content of a system, while entropy is the measure of disorder or randomness in a system.
Enthalpy is the sum of internal energy and the product of pressure and volume.
Entropy is the measure of the number of ways energy can be distributed in a system.
Heat loss in entropy occurs due to the transfer of energy from a hot object to a cold object.
Entropy always increases in a closed system, leading to a d...
AC is a device that cools and dehumidifies air while cooler is a device that cools water or other liquids.
AC is used to cool and dehumidify air in a room or building
Cooler is used to cool water or other liquids for drinking or industrial purposes
AC uses refrigerant to cool the air while cooler uses water or other liquids
AC is more expensive and complex than cooler
AC is more commonly used in residential and commercial b...
Top trending discussions
I applied via Walk-in and was interviewed before Aug 2020. There was 1 interview round.
I applied via Naukri.com and was interviewed in Sep 2022. There were 3 interview rounds.
I applied via Approached by Company and was interviewed before Jun 2022. There were 5 interview rounds.
Sub cooling in air conditioning is the process of cooling the refrigerant below its saturation temperature to improve system efficiency.
Sub cooling increases the efficiency of the air conditioning system by ensuring the refrigerant is in a liquid state before entering the expansion valve.
It helps in preventing flash evaporation of the refrigerant, which can lead to inefficiencies in the system.
Sub cooling is typically ...
ISEER rating is calculated based on the weighted average of the cooling performance of an air conditioner under different conditions.
ISEER = (Weighted Cooling Capacity at 100% load x 0.4) + (Weighted Cooling Capacity at 75% load x 0.2) + (Weighted Cooling Capacity at 50% load x 0.4)
The higher the ISEER rating, the more energy efficient the air conditioner is.
ISEER rating helps consumers compare the energy efficiency of...
The refrigeration cycle is a thermodynamic cycle used in refrigerators and air conditioning systems to transfer heat from a low temperature to a high temperature environment.
The cycle consists of four main components: compressor, condenser, expansion valve, and evaporator.
The refrigerant enters the compressor as a low-pressure gas and leaves as a high-pressure, high-temperature gas.
The high-pressure gas then flows into...
Mainstream refrigerants used in household air conditioning include R-410A, R-22, and R-134a.
R-410A is a popular refrigerant known for its high efficiency and environmental friendliness.
R-22, although being phased out due to its ozone-depleting properties, is still commonly found in older air conditioning systems.
R-134a is commonly used in automotive air conditioning systems but can also be found in some household units
1 ton cooling concept refers to the amount of heat required to melt one ton of ice in a 24-hour period.
1 ton of cooling is equal to 12,000 BTUs per hour
It is commonly used in the HVAC industry to measure the cooling capacity of air conditioning systems
For example, a 2-ton air conditioner can remove 24,000 BTUs of heat per hour
The relationship between current, voltage, and power is described by Ohm's Law, which states that current is directly proportional to voltage and inversely proportional to resistance.
Ohm's Law states that V = I * R, where V is voltage, I is current, and R is resistance.
Power (P) is calculated using the formula P = V * I, where P is power, V is voltage, and I is current.
In a circuit with a constant resistance, an increa...
1 BTU is approximately equal to 0.29307107 watts. To convert BTU to watts, multiply by 0.29307107. To convert watts to BTU, divide by 0.29307107.
1 BTU = 0.29307107 watts
To convert BTU to watts, multiply by 0.29307107
To convert watts to BTU, divide by 0.29307107
I applied via Job Portal
I applied via Approached by Company and was interviewed in Apr 2024. There was 1 interview round.
Types of process include batch process, continuous process, and hybrid process.
Batch process involves processing a set amount of materials at one time
Continuous process involves ongoing production without interruption
Hybrid process combines elements of both batch and continuous processes
Increasing product efficiency can be achieved through optimizing processes, improving technology, and enhancing employee skills.
Optimize production processes to eliminate waste and improve workflow
Upgrade technology to automate tasks and improve accuracy
Provide training and development opportunities for employees to enhance their skills and knowledge
I would improve the user interface to enhance user experience and streamline navigation.
Enhance user interface design for better usability
Streamline navigation to improve user experience
Implement user feedback to make necessary changes
Optimize performance for faster loading times
based on 1 interview
Interview experience
based on 10 reviews
Rating in categories
Assistant Manager
784
salaries
| ₹5 L/yr - ₹17 L/yr |
Senior Engineer
364
salaries
| ₹3.8 L/yr - ₹10.5 L/yr |
Deputy Manager
252
salaries
| ₹8.3 L/yr - ₹23 L/yr |
Senior Executive
152
salaries
| ₹4.3 L/yr - ₹9.1 L/yr |
Hvac Technician
148
salaries
| ₹0.9 L/yr - ₹5.2 L/yr |
OPPO
LG Electronics
Daikin
HP India