Bafna Pharmaceuticals Electrical Maintenance Engineer Interview Questions and Answers

Updated 1 Jun 2021

Bafna Pharmaceuticals Electrical Maintenance Engineer Interview Experiences

1 interview found

I applied via Walk-in and was interviewed in Dec 2020. There were 3 interview rounds.

Interview Questionnaire 

1 Question

  • Q1. Based on my experience

Interview Preparation Tips

Interview preparation tips for other job seekers - Technical wise

Interview questions from similar companies

Interview experience
3
Average
Difficulty level
Moderate
Process Duration
Less than 2 weeks
Result
Selected Selected

I applied via Walk-in and was interviewed before Mar 2023. There was 1 interview round.

Round 1 - Technical 

(4 Questions)

  • Q1. Star delta Starter control diagram
  • Ans. 

    Star delta starter is a method used to reduce the starting current of induction motors.

    • Star delta starter is used for starting induction motors in applications where the starting current needs to be limited.

    • In star connection, the motor windings are connected in a star configuration during starting to reduce the voltage across each winding.

    • After a certain time, the windings are switched to a delta configuration to run ...

  • Answered by AI
  • Q2. How to find motor current formulas
  • Ans. 

    Motor current formulas can be found using basic electrical principles and motor specifications.

    • Use Ohm's Law (I = V / R) to calculate current based on voltage and resistance.

    • For AC motors, use the formula I = P / (sqrt(3) * V * cos(theta)), where P is power, V is voltage, and theta is the power factor angle.

    • Refer to motor datasheets for specific current ratings and calculations.

    • Consider factors like efficiency, power f...

  • Answered by AI
  • Q3. Protection in a transformer
  • Ans. 

    Protection in a transformer involves measures to prevent damage from overcurrent, overvoltage, and overheating.

    • Use fuses or circuit breakers to protect against overcurrent

    • Install surge arresters to protect against overvoltage

    • Use temperature sensors and cooling systems to prevent overheating

    • Implement differential protection to detect internal faults

    • Regular maintenance and testing to ensure proper functioning

  • Answered by AI
  • Q4. Faults in a transformer
  • Ans. 

    Faults in a transformer can include short circuits, open circuits, overheating, and insulation breakdown.

    • Short circuits can occur due to insulation failure or winding damage.

    • Open circuits can result from broken connections or faulty windings.

    • Overheating may be caused by overloading or poor cooling.

    • Insulation breakdown can lead to arcing and short circuits.

  • Answered by AI

Tell us how to improve this page.

Interview Questions from Similar Companies

Cipla Interview Questions
4.1
 • 476 Interviews
Dr. Reddy's Interview Questions
4.1
 • 398 Interviews
Lupin Interview Questions
4.1
 • 332 Interviews
Aurobindo Pharma Interview Questions
4.0
 • 235 Interviews
Biocon Limited Interview Questions
3.9
 • 149 Interviews
View all
Executive
45 salaries
unlock blur

₹3 L/yr - ₹6.4 L/yr

Senior Executive
26 salaries
unlock blur

₹3.5 L/yr - ₹6.5 L/yr

Junior Executive
21 salaries
unlock blur

₹2.9 L/yr - ₹4.8 L/yr

Chemist
14 salaries
unlock blur

₹1.8 L/yr - ₹3.8 L/yr

Deputy Manager
13 salaries
unlock blur

₹8 L/yr - ₹10 L/yr

Explore more salaries
Compare Bafna Pharmaceuticals with

Sun Pharmaceutical Industries

4.0
Compare

Cipla

4.1
Compare

DRJ & CO

5.0
Compare

Lupin

4.1
Compare
Did you find this page helpful?
Yes No
write
Share an Interview