Air compressor works by compressing air to increase its pressure, which can then be used for various applications.
Air is drawn into the compressor through an intake valve.
The air is then compressed using a piston or rotating impeller.
The compressed air is stored in a tank or released directly for use.
The compressed air can be used for powering pneumatic tools, inflating tires, and more.
To troubleshoot overheating issue, check for dust buildup, ensure proper ventilation, monitor CPU usage, and consider upgrading cooling system.
Check for dust buildup in the computer's fans and vents
Ensure proper ventilation around the computer
Monitor CPU usage to identify any processes causing excessive heat
Consider upgrading the cooling system with better fans or a liquid cooling system
To overhaul an oil stop check valve, follow these steps:
1. Shut off the oil supply and relieve any pressure in the system.
2. Remove the valve from the pipeline using appropriate tools.
3. Disassemble the valve carefully, noting the position of each component.
4. Clean all parts thoroughly to remove any debris or buildup.
5. Inspect all components for wear or damage and replace any faulty parts.
6. Reassemble the valve in t...
A worn screw element can be identified by examining for signs of wear and tear, such as chipping, cracking, or deformation.
Inspect the screw element for any visible signs of chipping or cracking
Check for any deformation or warping of the screw element
Look for excessive wear on the threads of the screw element
Listen for any unusual noises during operation, which may indicate a worn screw element
Monitor the performance o...
Rate your
company
🤫 100% anonymous
How was your last interview experience?
Top trending discussions
I applied via Campus Placement and was interviewed before Jun 2020. There were 5 interview rounds.
GD&T is a system of symbols and standards used to communicate engineering design and manufacturing requirements.
GD&T stands for Geometric Dimensioning and Tolerancing
It is used to define the allowable variation in form, size, orientation, and location of features on a part
It ensures that parts are manufactured to the correct specifications and fit together properly
GD&T symbols include straightness, flatness, circularit...
I have worked on various DCS architectures in my career, including those for chemical plants and power plants.
Designed and implemented DCS architecture for a chemical plant project
Developed DCS architecture for a power plant project
Worked on DCS architecture for a water treatment plant project
Collaborated with team to create DCS architecture for a pharmaceutical plant project
Profibus is a widely used fieldbus communication protocol in industrial automation.
Profibus stands for Process Field Bus.
It is used for communication between field devices and control systems in industrial automation.
There are two main types of Profibus: Profibus DP (Decentralized Peripherals) and Profibus PA (Process Automation).
Profibus uses a master-slave communication model.
It is known for its high-speed data trans...
Troubleshooting Profibus involves checking physical connections, network configuration, and device settings.
Check physical connections to ensure cables are properly connected and not damaged.
Verify network configuration settings such as baud rate, parity, and address assignments.
Inspect device settings to ensure they match the network configuration and are functioning correctly.
Use diagnostic tools like Profibus analyz...
A control valve is a device used to regulate the flow of a fluid in a system by varying the size of the flow passage.
Control valves are commonly used in industries such as oil and gas, chemical, and power plants.
They can be operated manually, pneumatically, electrically, or through a combination of these methods.
The operation of a control valve involves adjusting the position of the valve plug or disc to control the fl...
The cable length for PA cables varies depending on the specific application, while the diameter is typically determined by the current carrying capacity and voltage requirements.
Cable length for PA cables can range from a few meters to several hundred meters, depending on the distance between the PA system and the speakers.
The diameter of PA cables is usually determined by the current carrying capacity and voltage requ...
There are two main types of smoke detectors: ionization and photoelectric.
Ionization smoke detectors use a small amount of radioactive material to ionize the air and detect smoke particles.
Photoelectric smoke detectors use a light beam to detect smoke particles in the air.
Dual sensor smoke detectors combine both ionization and photoelectric technologies for more comprehensive detection.
I am open to working from the office as needed for collaboration and team communication.
I believe in the importance of face-to-face interactions for effective communication and teamwork
I am flexible and willing to work from the office when required for project meetings or discussions
I understand the benefits of being physically present in the office for certain tasks or projects
I applied via LinkedIn and was interviewed in Dec 2024. There were 2 interview rounds.
Good experience in interview
I applied via Naukri.com and was interviewed in Apr 2021. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in Dec 2022. There were 2 interview rounds.
I am a highly skilled and experienced Project Engineer with a strong background in managing complex engineering projects.
Over 10 years of experience in project management and engineering
Proficient in utilizing project management software and tools
Strong leadership and communication skills
Proven track record of successfully delivering projects on time and within budget
Experience in coordinating with cross-functional tea...
I have worked on various projects in my previous company, including the construction of a new office building and the implementation of a software system for project management.
Construction of a new office building
Implementation of a software system for project management
The lifecycle of a project refers to the stages it goes through from initiation to closure.
Initiation: project is defined and approved
Planning: project objectives, scope, and resources are determined
Execution: project plan is put into action
Monitoring and Control: project progress is tracked and necessary adjustments are made
Closure: project is completed and evaluated
Examples: construction of a building, development of...
Industrial communication protocols are standards for data exchange between devices in industrial automation and control systems.
Some common industrial communication protocols include Modbus, Profibus, DeviceNet, Ethernet/IP, and CANopen.
These protocols enable devices from different manufacturers to communicate with each other and exchange data.
Industrial communication protocols can be wired or wireless, and can operate...
MODBUS settings include baud rate, parity, data bits, stop bits, and slave address.
Baud rate determines the speed of communication between devices.
Parity is used for error checking and can be set to even, odd, or none.
Data bits determine the number of bits used to represent each character.
Stop bits indicate the end of a character and can be set to 1 or 2.
Slave address is used to identify the device on the network.
Examp...
The maximum speed in Modbus depends on the baud rate and cable length.
Modbus speed is measured in baud rate
Higher baud rates allow for faster data transfer
Cable length can also affect the maximum speed
For example, at 9600 baud rate, the maximum cable length is 1200 meters
The number of devices that can be added in Modbus depends on the network architecture and the number of available addresses.
The maximum number of devices that can be added to a Modbus network is 247.
The number of available addresses depends on the type of Modbus protocol used (RTU or TCP/IP).
The network architecture also plays a role in determining the number of devices that can be added.
It is important to ensure that ...
Modbus communication types include RTU, ASCII, and TCP/IP.
RTU (Remote Terminal Unit) is a serial communication protocol that uses binary code to transmit data.
ASCII (American Standard Code for Information Interchange) is a serial communication protocol that uses ASCII characters to transmit data.
TCP/IP (Transmission Control Protocol/Internet Protocol) is a network communication protocol that uses Ethernet to transmit d...
I have worked on multiple SCADA systems including Wonderware, Ignition, and Inductive Automation.
I have experience with configuring and programming SCADA systems
I have worked with Wonderware, Ignition, and Inductive Automation
I am familiar with creating HMI screens, alarms, and trends
I have experience with PLC communication and data acquisition
I have worked on projects in various industries including manufacturing and
The maximum input output handle refers to the maximum number of inputs and outputs that a device can handle.
The maximum input output handle varies depending on the device and its specifications.
It is important to consider the maximum input output handle when selecting a device for a project.
For example, a PLC may have a maximum input output handle of 256 inputs and 256 outputs.
Another example is a microcontroller with ...
The number of pages designed in HMI depends on the project requirements and complexity.
The number of pages can range from a few to hundreds depending on the project scope.
The complexity of the HMI design and functionality also affects the number of pages.
Factors such as user interface, data visualization, and system integration can impact the number of pages.
It is important to prioritize user experience and ease of nav
based on 1 interview
Interview experience
Anonymously discuss salaries, work culture, and many more
Get Ambitionbox App
based on 2 reviews
Rating in categories
Design Engineer
291
salaries
| ₹0 L/yr - ₹0 L/yr |
Service Engineer
231
salaries
| ₹0 L/yr - ₹0 L/yr |
Project Engineer
169
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Design Engineer
168
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Service Engineer
97
salaries
| ₹0 L/yr - ₹0 L/yr |
Ingersoll Rand
Sandvik Asia
Caterpillar Inc
Epiroc