Initial setting time of cement is the time taken by cement to harden and resist penetration by a standard needle.
Initial setting time is affected by factors like temperature, water-cement ratio, and type of cement.
The standard needle used for testing has a diameter of 1.13 mm and a length of 50 mm.
The initial setting time of ordinary Portland cement is around 30 minutes.
The initial setting time of rapid hardening cemen
Lime test stone test brick test
Top trending discussions
I applied via Company Website and was interviewed before May 2021. There was 1 interview round.
Impedance is the measure of opposition to the flow of electric current in a circuit. DGR fundamental refers to the Dielectric Withstand Voltage test.
Impedance is measured in ohms and is the combination of resistance, capacitance, and inductance in a circuit.
DGR fundamental is a test to determine the maximum voltage a material can withstand without breaking down.
Basics of impedance include understanding the relationship...
I applied via Naukri.com and was interviewed in Nov 2021. There was 1 interview round.
Impedance is the total opposition to the flow of alternating current in a circuit, while reactance is the opposition to the flow of alternating current caused by capacitance or inductance.
Impedance is a combination of resistance and reactance in a circuit.
Reactance is the opposition to the flow of alternating current caused by capacitance or inductance.
Capacitive reactance is the opposition to the flow of alternating c...
Plant load factor is calculated by dividing the actual energy generated by the maximum possible energy that could have been generated.
Plant load factor = Actual energy generated / Maximum possible energy that could have been generated
Maximum possible energy is calculated by multiplying the rated capacity of the plant with the number of hours in a given time period
Plant load factor is expressed as a percentage
It is used...
I appeared for an interview in Oct 2017.
I applied via Walk-in and was interviewed before Jun 2019. There was 1 interview round.
Star delta connection is a method of connecting three-phase motors to reduce starting current.
Used for high power motors
Reduces starting current
Requires six leads
Switches from star to delta during operation
Used in industries such as oil and gas, mining, and manufacturing
A transformer is an electrical device that transfers electrical energy from one circuit to another through electromagnetic induction.
Transformers are used to increase or decrease the voltage of an alternating current (AC) power supply.
They consist of two coils of wire, called the primary and secondary coils, wrapped around a magnetic core.
When an AC current flows through the primary coil, it creates a magnetic field th...
Ohm's law states that the current through a conductor between two points is directly proportional to the voltage across the two points.
Ohm's law is represented by the equation V = IR, where V is voltage, I is current, and R is resistance.
The power formula is P = VI, where P is power, V is voltage, and I is current.
Ohm's law is used to calculate the resistance of a circuit and to determine the amount of current flowing ...
I applied via Job Portal and was interviewed before Sep 2021. There were 3 interview rounds.
based on 1 interview
Interview experience
based on 7 reviews
Rating in categories
Design Engineer
80
salaries
| ₹3.6 L/yr - ₹13.3 L/yr |
Assistant Design Engineer
52
salaries
| ₹3 L/yr - ₹6 L/yr |
Consultant Engineer
52
salaries
| ₹4.8 L/yr - ₹10 L/yr |
Structural Design Engineer
50
salaries
| ₹3.3 L/yr - ₹12.5 L/yr |
Senior Manager
32
salaries
| ₹12.5 L/yr - ₹32 L/yr |
Suzlon Group
Torrent Power
Eaton
Vestas