Filter interviews by
Top trending discussions
I applied via Walk-in and was interviewed before Oct 2020. There were 3 interview rounds.
DTR stands for Data Terminal Ready.
DTR is a control signal used in serial communication.
It indicates that a data terminal equipment (DTE) is ready to communicate.
DTR is typically used to signal the start of a connection or to reset a device.
In RS-232 communication, DTR is often used to control the flow of data.
For example, when DTR is set to high, it indicates that the DTE is ready to send or receive data.
DTR structure consists of transformer, rectifier, and filter components.
Transformer: used to step down the voltage from the power source
Rectifier: used to convert AC to DC
Filter: used to smooth out the DC output
Components may include diodes, capacitors, resistors, and inductors
Example: DTR structure is commonly used in power supplies for electronic devices
The number of transformer ratings required for 50 households depends on their power consumption and distribution network.
The power consumption of each household needs to be determined
The distribution network and voltage level also affect the transformer rating
Assuming an average power consumption of 1 kW per household, a 50 kW transformer may be required
However, this can vary greatly depending on the specific circumsta
posted on 27 Jan 2021
I applied via Recruitment Consultant and was interviewed in Jul 2020. There were 4 interview rounds.
I have experience in drawing various types of bridges including beam, truss, arch, suspension, and cable-stayed bridges.
Beam bridges - simple and economical design with horizontal beams supported by piers or abutments
Truss bridges - composed of interconnected triangles for added strength and stability
Arch bridges - curved design that distributes weight evenly to supports at each end
Suspension bridges - main cables anch...
posted on 4 May 2019
To design busbar for increased fault level but same current rating, increase the cross-sectional area of the busbar.
Increase the thickness of the busbar
Increase the width of the busbar
Use materials with higher conductivity
Use busbar supports with higher short-circuit strength
Consider the temperature rise of the busbar
Perform a fault level calculation to determine the required cross-sectional area
The bending radius for HT cables varies depending on the cable type and size.
The bending radius for XLPE cables is typically 12 times the cable diameter.
For PILC cables, the bending radius is usually 20 times the cable diameter.
The bending radius for EPR cables is generally 10 times the cable diameter.
It is important to follow the manufacturer's recommendations for bending radius to avoid damaging the cable.
Bending rad...
I am currently working as an Electrical Engineer in a power distribution company.
Designing electrical systems for power distribution
Analyzing power consumption data
Troubleshooting electrical issues
Collaborating with other engineers on projects
I am looking for a competitive salary that aligns with my experience and skills in the industry.
Research industry standards for Electrical Engineers in the specific location
Consider years of experience and level of expertise
Factor in benefits and opportunities for growth within the company
I am currently working as a Senior Electrical Engineer at XYZ Company.
Senior Electrical Engineer at XYZ Company
Responsible for designing and implementing electrical systems
Leading a team of engineers in project execution
I applied via Job Fair and was interviewed in May 2018. There were 3 interview rounds.
I applied via Walk-in and was interviewed before Feb 2021. There were 2 interview rounds.
I applied via Company Website and was interviewed before Aug 2020. There were 3 interview rounds.
posted on 30 Apr 2021
Lighting levels for indoor and outdoor areas are determined based on the purpose of the space and the activities that take place.
Indoor lighting levels are typically measured in foot-candles or lux
Outdoor lighting levels are typically measured in lumens per square meter
Calculation procedures involve determining the required illuminance level for the space and selecting appropriate light fixtures and bulbs
Factors such a...
Cable glands are used to secure and seal cables in various applications based on the area of installation.
Cable glands are used in hazardous areas to prevent the entry of flammable gases and liquids.
In outdoor applications, cable glands are used to protect cables from moisture and dust.
In industrial settings, cable glands are used to secure cables and prevent them from being pulled out.
Different types of cable glands a...
posted on 12 Oct 2024
I applied via Campus Placement and was interviewed in Sep 2024. There were 3 interview rounds.
General knowlegde, Basic Aptitude, Domain Technical MCQ
Genx vs Genz, Altitude and comparsion
Components of a transformer include core, windings, and insulation.
Core: Provides a path for magnetic flux
Windings: Primary and secondary coils for inducing voltage
Insulation: Prevents short circuits and ensures safety
posted on 24 Oct 2024
Basic electronics and electrical questions
Topic is About GenC and GenX
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Project Engineer
35
salaries
| ₹3.5 L/yr - ₹4.5 L/yr |
Electrical Engineer
26
salaries
| ₹3.5 L/yr - ₹9.5 L/yr |
Instrument Engineer
24
salaries
| ₹2.4 L/yr - ₹8 L/yr |
Instrumentation Technician
19
salaries
| ₹2.3 L/yr - ₹4.2 L/yr |
Safety Officer
16
salaries
| ₹3.2 L/yr - ₹5.8 L/yr |
L&T Construction
Simplex Infrastructures
ITD Cementation India
Ashoka Buildcon