Q1. What IS Codes do you follow for structural steel fabrication and erection works?
I follow IS 800:2007 and IS 875:1987 codes for structural steel fabrication and erection works.
IS 800:2007 specifies general requirements for design, fabrication, and erection of structural steelwork.
IS 875:1987 provides guidelines for loads and forces to be considered in the design of structures.
Other relevant codes include IS 2062:2011 for steel plates and IS 808:1989 for rolled steel beams.
Adherence to these codes ensures safety, quality, and durability of the steel struct...read more
Q2. Did you fabricate Built Up Sections? If yes, please explain the requirement of Built Up sections over Rolled Sections? What are the common problems do you face while fabricating Built Up Sections?
Yes, I have fabricated Built Up Sections. Built Up Sections are required when the load-bearing capacity of Rolled Sections is insufficient.
Built Up Sections are made by welding two or more Rolled Sections together to increase their load-bearing capacity.
They are commonly used in construction of bridges, high-rise buildings, and industrial structures.
Common problems faced while fabricating Built Up Sections include welding defects, distortion, and buckling.
Proper welding techn...read more
Q3. Please explain briefly the step wise process of fabrication and erection of a storage tank as per standard API code.
The fabrication and erection of a storage tank as per API code involves several steps.
The tank design is finalized based on the intended use and specifications.
The materials for the tank are selected and procured.
The plates are cut and rolled to form the shell and heads of the tank.
The shell and heads are welded together to form the tank.
The tank is hydrotested to ensure it can withstand the intended pressure.
The tank is sandblasted and painted to protect against corrosion.
Th...read more
Q4. What are common NDT methods followed for Tank Fabrication works?
Common NDT methods for Tank Fabrication works
Visual Inspection
Ultrasonic Testing
Magnetic Particle Inspection
Radiographic Testing
Dye Penetrant Inspection
Q5. Are you willing to relocate as this is a wfo mode
Yes, I am willing to relocate for the position of Assistant Manager.
I am open to new opportunities and challenges in my career.
I understand that this is a wfo mode and relocation may be necessary.
I am willing to relocate to ensure the success of the company and my own career growth.
I have experience in relocating for work in the past and am comfortable with the process.
Q6. Briefly explain the Vacuum Box test method for Tanks.
Vacuum Box test is a non-destructive testing method used to detect leaks or defects in tanks.
The tank is pressurized with air or water and then a vacuum is applied to the tank's exterior.
A vacuum box is placed over the suspected leak area and a vacuum is applied to the box.
If the vacuum level drops, it indicates a leak in the tank.
This method is commonly used in the oil and gas industry to test storage tanks and pipelines.
It is a cost-effective and efficient way to detect lea...read more
Q7. What is your knowledge on SIEM tools
SIEM tools are used for security information management and event management.
SIEM tools collect and analyze security-related data from various sources
They provide real-time monitoring and alerting of security incidents
Examples of SIEM tools include Splunk, IBM QRadar, and LogRhythm
Q8. Man in the middle attack
Man in the middle attack is a type of cyber attack where the attacker intercepts communication between two parties.
The attacker intercepts communication between two parties and can eavesdrop or alter the communication
It can be done through various methods such as ARP spoofing, DNS spoofing, etc.
It can be prevented by using encryption, digital signatures, and secure communication protocols
Q9. How will manger in sales
A sales manager is responsible for leading and motivating a sales team to achieve sales targets and drive business growth.
A sales manager should have strong leadership and communication skills.
They should be able to set sales targets and develop strategies to achieve them.
They should motivate and train the sales team to improve performance.
A sales manager should analyze sales data and market trends to identify opportunities and make informed decisions.
They should build and ma...read more
Q10. Maximum Qty pour at a time
The maximum quantity that can be poured at a time depends on the size and capacity of the container being used.
The maximum quantity that can be poured at a time is determined by the size of the container.
Factors such as viscosity of the liquid, pouring speed, and skill of the person pouring also play a role.
For example, a small cup may only be able to pour a few ounces at a time, while a large pitcher could pour several cups.
More about working at Adani Group
Top HR Questions asked in LrDmc Travel
Interview Process at LrDmc Travel
Top Assistant Manager Interview Questions from Similar Companies
Reviews
Interviews
Salaries
Users/Month