i
ABB
Filter interviews by
I applied via Recruitment Consultant and was interviewed in Jun 2021. There was 1 interview round.
Seven steps for electrical safety
Identify potential electrical hazards
Develop and implement safety procedures
Provide proper training to employees
Use appropriate personal protective equipment
Regularly inspect and maintain electrical equipment
Ensure proper grounding and wiring
Respond promptly to any electrical incidents
Activity stop take 5 is a safety procedure to pause work and identify potential hazards.
It is a safety measure to prevent accidents and injuries.
It involves stopping work for 5 minutes to identify any potential hazards.
During this time, workers can discuss safety concerns and take corrective actions.
It is commonly used in industries such as construction, manufacturing, and oil and gas.
It helps to promote a safety cultu
I applied via Referral and was interviewed before Aug 2023. There was 1 interview round.
Implemented a comprehensive HSE management system focusing on risk assessment, training, and incident investigation.
Conducted regular risk assessments to identify potential hazards
Provided HSE training to all employees on a regular basis
Established a system for reporting and investigating incidents
Implemented corrective actions to prevent future incidents
Regularly reviewed and updated HSE policies and procedures
Current is the flow of electric charge in a circuit.
Current is measured in Amperes (A)
It is the rate of flow of electric charge
Current flows from high voltage to low voltage
In a series circuit, the current is the same at all points
In a parallel circuit, the total current is the sum of the currents through each branch
Soft starters are preferred over star-delta starters for motor start and run due to their ability to reduce inrush current and provide smoother acceleration.
Soft starters provide a gradual increase in voltage to the motor, reducing inrush current and mechanical stress on the motor.
Star-delta starters provide a sudden increase in voltage, resulting in high inrush current and mechanical stress on the motor.
Soft starters ...
Encoders used in industrial include absolute, incremental, linear, rotary, magnetic, and optical encoders.
Absolute encoders provide a unique code for each position
Incremental encoders provide a pulse output for each position change
Linear encoders measure linear motion
Rotary encoders measure rotational motion
Magnetic encoders use a magnetic field to detect position
Optical encoders use light to detect position
VFD parameters are settings that control the operation of a variable frequency drive.
VFD parameters include frequency, voltage, current, acceleration/deceleration time, and motor overload protection
Frequency parameter determines the speed of the motor
Voltage parameter determines the amount of voltage supplied to the motor
Current parameter determines the amount of current supplied to the motor
Acceleration/deceleration t...
I applied via AmbitionBox and was interviewed in May 2022. There were 2 interview rounds.
HIRA stands for Hazard Identification and Risk Assessment. It is a process used to identify potential hazards and assess the associated risks.
HIRA involves identifying hazards and assessing the risks associated with them
The process includes analyzing the likelihood and severity of potential incidents
Examples of hazards that may be identified through HIRA include chemical spills, equipment malfunctions, and workplace vi
based on 2 reviews
Rating in categories
Project Engineer
573
salaries
| ₹5.4 L/yr - ₹18.3 L/yr |
R&D Engineer
331
salaries
| ₹6.5 L/yr - ₹23 L/yr |
Financial Analyst
263
salaries
| ₹2 L/yr - ₹10 L/yr |
Design Engineer
234
salaries
| ₹0.9 L/yr - ₹9.5 L/yr |
Associate Project Engineer
207
salaries
| ₹5 L/yr - ₹12 L/yr |
Siemens
Schneider Electric
Emerson Electric Co.
Honeywell International India