No, normal copper wire cannot be used in place of thermocouple compensating wire due to different composition and temperature range.
Thermocouple compensating wire is specifically designed to match the thermal properties of the thermocouple material.
Normal copper wire does not have the same composition as compensating wire, leading to inaccurate temperature readings.
Compensating wire can withstand higher temperatures co...
VFD stands for Variable Frequency Drive, used to control the speed of an AC motor by varying the frequency and voltage supplied to the motor.
VFD consists of three main components: rectifier, DC bus, and inverter.
Rectifier converts AC power to DC power.
DC bus stores the converted DC power.
Inverter converts DC power back to AC power with variable frequency and voltage.
VFD allows for precise control of motor speed, reduci...
Gas analyzer block diagram consists of sample inlet, gas sensor, signal processing unit, and display.
Gas sample is drawn into the analyzer through a sample inlet.
The gas sensor detects the presence of specific gases in the sample.
The signal processing unit processes the sensor data and calculates the gas concentration.
The results are displayed on a screen for the user to read.
Examples of gas analyzers include infrared ...
Top trending discussions
I applied via Naukri.com and was interviewed in Dec 2023. There were 5 interview rounds.
I applied via Naukri.com and was interviewed in Sep 2022. There were 2 interview rounds.
A VFD gas analyzer system is a system that uses variable frequency drives to control the speed of the gas analyzer pump.
VFD gas analyzer systems are commonly used in industrial settings to monitor and control gas emissions.
The system uses a VFD to control the speed of the pump, which in turn controls the flow rate of the gas being analyzed.
This allows for more accurate and precise measurements of gas concentrations.
VFD...
The number of I/O in the plant is approximately X.
The exact number of I/O in the plant can vary depending on the size and complexity of the plant.
I/O stands for input/output and refers to the communication between different devices and systems in the plant.
The number of I/O can be determined by looking at the plant's control system documentation.
Some plants may have thousands of I/O points, while others may have only a...
posted on 6 Jan 2023
posted on 9 Mar 2022
I was interviewed before Mar 2021.
I applied via Recruitment Consultant and was interviewed before Aug 2020. There was 1 interview round.
Some of the top questions asked at the Wonder Cement Instrument Engineer interview -
based on 1 interview
Interview experience
based on 4 reviews
Rating in categories
Associate Manager
186
salaries
| ₹7.8 L/yr - ₹17.7 L/yr |
Senior Engineer
139
salaries
| ₹4.9 L/yr - ₹11.8 L/yr |
Assistant Manager
124
salaries
| ₹6.7 L/yr - ₹14.6 L/yr |
Mechanical Engineer
105
salaries
| ₹2.1 L/yr - ₹6.9 L/yr |
Engineer
94
salaries
| ₹3.2 L/yr - ₹6.8 L/yr |
UltraTech Cement
Ambuja Cements
ACC
Shree Cement